Calibration and application of radiometer for low-temperature infrared radiation source

被引:0
|
作者
Shi, Qingfeng [1 ,2 ]
Gao, Yanze [1 ,2 ]
Li, Zhuo [1 ,2 ]
Shi, Rui [1 ,2 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing 100081, Peoples R China
[2] Beijing Key Lab Precis Optoelect Measurement Inst, Beijing 100081, Peoples R China
基金
中国博士后科学基金;
关键词
radiation calibration; low-temperature infrared radiation; infrared radiometer;
D O I
10.1117/12.2606178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In response to the current increasing demand for calibration of low-temperature infrared radiation sources with a large dynamic range, this paper studies a calibration method for low-temperature infrared radiation sources with a temperature range of 100-450K. The improvement of the signal-to-noise ratio of the input signal by related detection techniques is analyzed. Developed a radiation calibration device, also called a radiometer, analyzed the calibration and measurement process of the radiometer, and established a corresponding mathematical model. The experimental results show that the minimum radiation intensity that can be measured by the radiometer is 2.47x10(-12) W, and the response rate of the radiometer is 102878.38 V/W. Use the calibrated radiometer to measure the target simulator. The source and contribution of the uncertainty of the radiometer in the measurement process are analyzed.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] LOW-TEMPERATURE INFRARED SPECTRA OF SUGARS
    KATON, JE
    MILLER, JT
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1967, 121 (03) : 798 - &
  • [32] DESCRIPTION OF A LOW-TEMPERATURE INFRARED CELL
    SCHNOCKEL, H
    WILLNER, H
    ZEITSCHRIFT FUR ANORGANISCHE UND ALLGEMEINE CHEMIE, 1974, 408 (03): : 247 - 254
  • [33] Feasibility Analysis of Application of Low-Temperature Radiation Electric Heating System
    Yang Jin-gang
    Yang Li-kai
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 2427 - 2431
  • [34] External field calibration method for low temperature section of infrared radiation measuring equipment
    Lu Xiaofei
    Zhang li
    Li Yi
    Zhao Hui
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES VII, 2020, 11559
  • [35] THERMAL ANCHORING AND CALIBRATION OF LOW-TEMPERATURE SENSORS
    KOEPPE, W
    KERNTECHNIK, 1973, 15 (08) : 353 - 357
  • [36] Low-temperature blackbodies and facility for calibration of them
    Morozova, SP
    Morozov, PA
    Sapritsky, VI
    Lisiansky, BE
    Dovgilov, NL
    Liang, YX
    Li, YM
    Yue, WL
    OPTICAL DESIGN AND TESTING, 2002, 4927 : 118 - 124
  • [37] LOW-TEMPERATURE ION-SOURCE
    TANABE, S
    TONEGAWA, A
    TAKAYAMA, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 1362 - 1364
  • [38] LOW-TEMPERATURE NOZZLE BEAM SOURCE
    SKOFRONICK, JG
    POPE, WM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (01): : 76 - 77
  • [39] APPLICATION OF LOW-TEMPERATURE CARBONIZATION
    ZINN, RE
    CHEMICAL ENGINEERING PROGRESS, 1954, 50 (01) : 3 - 7
  • [40] Research on calibration method of relative infrared radiometer
    Yang, Sen
    Li, Chengwei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):