Calibration and application of radiometer for low-temperature infrared radiation source

被引:0
|
作者
Shi, Qingfeng [1 ,2 ]
Gao, Yanze [1 ,2 ]
Li, Zhuo [1 ,2 ]
Shi, Rui [1 ,2 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing 100081, Peoples R China
[2] Beijing Key Lab Precis Optoelect Measurement Inst, Beijing 100081, Peoples R China
基金
中国博士后科学基金;
关键词
radiation calibration; low-temperature infrared radiation; infrared radiometer;
D O I
10.1117/12.2606178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In response to the current increasing demand for calibration of low-temperature infrared radiation sources with a large dynamic range, this paper studies a calibration method for low-temperature infrared radiation sources with a temperature range of 100-450K. The improvement of the signal-to-noise ratio of the input signal by related detection techniques is analyzed. Developed a radiation calibration device, also called a radiometer, analyzed the calibration and measurement process of the radiometer, and established a corresponding mathematical model. The experimental results show that the minimum radiation intensity that can be measured by the radiometer is 2.47x10(-12) W, and the response rate of the radiometer is 102878.38 V/W. Use the calibrated radiometer to measure the target simulator. The source and contribution of the uncertainty of the radiometer in the measurement process are analyzed.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Low-temperature radiation chemistry
    Kiryukhin, D. P.
    HIGH ENERGY CHEMISTRY, 2011, 45 (03) : 165 - 182
  • [22] Low-temperature radiation chemistry
    D. P. Kiryukhin
    High Energy Chemistry, 2011, 45 : 165 - 182
  • [23] LOW-TEMPERATURE INSULATION - THERMAL INSULATION FOR LOW-TEMPERATURE APPLICATION
    BRADLEY, CB
    STONE, JF
    CHEMICAL ENGINEERING PROGRESS, 1948, 44 (09) : 723 - 726
  • [24] Calibration methods of infrared spectrum radiometer at various temperatures and background temperature adjustment
    Huang, Y
    Fang, YH
    Xun, YL
    Xiong, W
    Qiao, YL
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2004, 23 (02) : 131 - 134
  • [25] LOW-TEMPERATURE NONLINEAR ABSORPTION OF INFRARED RADIATION IN N-TYPE GE
    AVETISYAN, SK
    MINASYAN, GR
    ENFIADZHYAN, RL
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1990, 24 (04): : 484 - 485
  • [26] Performance of radiation on film-type infrared flare with low-temperature combustion
    Lin, Hongxue
    Zhu, Chenguang
    Li, Min
    Wang, Haizhen
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2014, 43 (10): : 3193 - 3198
  • [27] APPLICATION OF LOW-TEMPERATURE IONS IN THE NONEQUILIBRIUM STATE PLASMA OF A PENNING SOURCE
    SATO, Y
    OGAWA, H
    YAMADA, S
    YAMADA, T
    KOHNO, T
    JOURNAL OF APPLIED PHYSICS, 1991, 69 (11) : 7933 - 7935
  • [28] CALIBRATION OF RADIOMETER FOR LONGWAVE RADIATION (I) - CASE OF NET RADIOMETER
    KANO, M
    SUZUKI, M
    YATA, A
    PAPERS IN METEOROLOGY AND GEOPHYSICS, 1973, 24 (02) : 249 - 261
  • [29] LOW-TEMPERATURE INFRARED MEASUREMENTS OF NI
    MINKWITZ, R
    FROBEN, FW
    CHEMICAL PHYSICS LETTERS, 1976, 39 (03) : 473 - 475
  • [30] LOW-TEMPERATURE INFRARED SPECTRA OF CARBOHYDRATES
    MICHELL, AJ
    AUSTRALIAN JOURNAL OF CHEMISTRY, 1970, 23 (04) : 833 - &