Object. The purpose of this study was to investigate whether thicker-core-diameter screws increase fixation strength in the cervical spine. Methods. Bone mineral density (BMD) was determined for each vertebral body (VB) obtained in six human C4-7 segments. Based on their BMD, the specimens were assigned to one of two groups in which torque and pullout force were tested. Two initial pilot holes were drilled into the VBs and tests were first performed using a standard screw. The test was repeated using a thicker rescue screw inserted into the same initial pilot hole. The mean value of peak torque and pullout force resulting from the single left/right measurements was used for statistical analysis. A t-test was performed to determine the effect of screw design on peak torque and pullout force. Moment correlation coefficients were calculated to determine the effect of BMD on peak torque and pullout force. Mean insertional peak torque for the standard screw was 82.1 N/cm and that for the rescue screw was 47.6 Ncm (p < 0.001). There was a strong correlation between insertional peak torque and BMD for both standard screws (r = 0.71, p = 0.02) and rescue screws (r = 0.59, p = 0.07). The mean pullout force for standard screws was 464.7 N, whereas it was 164.5 N for rescue screws (p < 0.001). There was a strong correlation between pullout force and BMD for both standard (r = 0.75, p = 0.0081) and rescue screws (r = 0.7, p = 0.025). Conclusions. Uncemented rescue screws that have been inserted into a fatigued hole in the cervical VB do not strengthen the screw-bone interface compared with the strength initially conferred by a standard screw.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 16 条
  • [1] Divergent Configuration Improves Insertion Torque and Pullout Strength of Anterior Cervical Screws
    Xavier, Fred
    Saha, Subrata
    2016 32ND SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE (SBEC), 2016, : 98 - 98
  • [2] Effectiveness of cemented rescue screws for anterior cervical plate fixation
    Pitzen, TR
    Drumm, J
    Bruchmann, B
    Barbier, DD
    Steudel, WI
    JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (01) : 60 - 63
  • [3] The Effect of Repetitive Pilot-Hole Use on the Insertion Torque and Pullout Strength of Vertebral System Screws
    Defino, Helton L. A.
    Rosa, Rodrigo Cesar
    Silva, Patricia
    Shimano, Antonio Carlos
    Volpon, Jose Batista
    Albuquerque de Paula, Francisco Jose
    Schleicher, Philipp
    Schnake, Klaus
    Kandziora, Frank
    SPINE, 2009, 34 (09) : 871 - 876
  • [4] CORRELATIONS BETWEEN SCREW HOLE PREPARATION, TORQUE OF INSERTION, AND PULLOUT STRENGTH FOR SPINAL SCREWS
    DAFTARI, TK
    HORTON, WC
    HUTTON, WC
    JOURNAL OF SPINAL DISORDERS, 1994, 7 (02): : 139 - 145
  • [5] Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws
    Heidemann, W
    Gerlach, KL
    Grobel, KH
    Kollner, HG
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (01) : 50 - 55
  • [6] Effect of pilot hole diameter and tapping on insertion torque and axial pullout strength of 4.0-mm cancellous bone screws
    Kunkel, Kevin A. R.
    Suber, Jonathan T.
    Gerard, Patrick D.
    Kowaleski, Michael P.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (12) : 1660 - 1665
  • [7] The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone
    Battula, Suneel
    Schoenfeld, Andrew J.
    Sahai, Vivek
    Vrabec, Gregory A.
    Tank, Jason
    Njus, Glen O.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (04): : 990 - 995
  • [8] BIOMECHANICAL ANALYSIS OF BONE-MINERAL DENSITY, INSERTION TECHNIQUE, SCREW TORQUE, AND HOLDING STRENGTH OF ANTERIOR CERVICAL PLATE SCREWS
    RYKEN, TC
    CLAUSEN, JD
    TRAYNELIS, VC
    GOEL, VK
    JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 324 - 329
  • [9] Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating
    Pitzen, T
    Barbier, D
    Tintinger, F
    Steudel, WI
    Strowitzki, M
    EUROPEAN SPINE JOURNAL, 2002, 11 (05) : 494 - 499
  • [10] Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating
    T. Pitzen
    D. Barbier
    F. Tintinger
    W. Steudel
    M. Strowitzki
    European Spine Journal, 2002, 11 : 494 - 499