Calibration of 192Ir High Dose Rate Brachytherapy Source Using Water Phantom

被引:0
|
作者
Yu, L. [1 ]
Yang, B. [1 ]
Liu, X. [1 ]
Pang, T. [1 ]
Liu, N. [1 ]
Li, B. [1 ]
Dong, T. [1 ]
Wang, B. [1 ]
Wang, Z. [1 ]
Qiu, J. [1 ]
机构
[1] Beijing Union Med Coll Hosp, Beijing, Peoples R China
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-P
引用
收藏
页码:E212 / E212
页数:1
相关论文
共 50 条
  • [31] Verification of High Dose Rate 192Ir Source Position During Brachytherapy Treatment Using Silicon Pixel Detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2250 - 2256
  • [32] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [33] A practical implementation of the 2010 IPEM high dose rate brachytherapy code of practice for the calibration of 192Ir sources
    Awunor, O. A.
    Lecomber, A. R.
    Richmond, N.
    Walker, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5397 - 5410
  • [34] Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
    Rostami, Atefeh
    Hoseini, Mahdi
    Ghorbani, Mahdi
    Knaup, Courtney
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 139 - 145
  • [35] First experience of 192Ir source stuck event during high-dose-rate brachytherapy in Japan
    Kumagai, Shinobu
    Arai, Norikazu
    Takata, Takeshi
    Kon, Daisuke
    Saitoh, Toshiya
    Oba, Hiroshi
    Furui, Shigeru
    Kotoku, Jun'ichi
    Shiraishi, Kenshiro
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (01) : 53 - 60
  • [36] Calculation of dose decrease in a finite phantom of a 192Ir point source
    Melchert, Corinna
    Kohr, P.
    Schmidt, R.
    MEDICAL PHYSICS, 2007, 34 (10) : 3943 - 3950
  • [37] A standard graphite calorimeter for dosimetry in brachytherapy with high dose rate 192Ir sources
    Guerra, A. S.
    Loreti, S.
    Pimpinella, M.
    Quini, M.
    D'Arienzo, M.
    Astefanoaei, I.
    Caporali, C.
    Bolzan, C.
    Pagliari, M.
    METROLOGIA, 2012, 49 (05) : S179 - S183
  • [38] Determination of the dose rate around a HDR 192Ir brachytherapy source with the microDiamond and the microSilicon detector
    Rossi, Giulio
    Failing, Thomas
    Gainey, Mark
    Kollefrath, Michael
    Hensley, Frank
    Zink, Klemens
    Baltas, Dimos
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (04): : 463 - 478
  • [39] Dose optimization of breast balloon brachytherapy using a stepping 192Ir HDR source
    Choi, Chang Hyun
    Ye, Sung-Joon
    Parsai, E. Ishmael
    Shen, Sui
    Meredith, Ruby
    Brezovich, Ivan A.
    Ove, Roger
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 90 - 102
  • [40] On the water equivalence of thirteen commercially available phantom materials in 192Ir brachytherapy
    Schoenfeld, A.
    Harder, D.
    Poppe, B.
    Chofor, N.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S471 - S472