Determination of the dose rate around a HDR 192Ir brachytherapy source with the microDiamond and the microSilicon detector

被引:3
|
作者
Rossi, Giulio [1 ,2 ,8 ]
Failing, Thomas [3 ,4 ]
Gainey, Mark [1 ,2 ]
Kollefrath, Michael [1 ,2 ]
Hensley, Frank [5 ]
Zink, Klemens [3 ,6 ,7 ]
Baltas, Dimos [1 ,2 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Radiat Oncol, Freiburg, Germany
[2] German Canc Res Ctr, German Canc Consortium DKTK Partner Site Freiburg, Heidelberg, Germany
[3] Univ Appl Sci Giessen, Inst Med Phys & Radiat Protect, Giessen, Germany
[4] Univ Med Ctr Gottingen, Dept Radiat Oncol, Gottingen, Germany
[5] Univ Hosp Heidelberg, Dept Radiat Oncol, Heidelberg, Germany
[6] Univ Med Ctr Giessen Marburg, Dept Radiotherapy & Radiat Oncol, Marburg, Germany
[7] Marburg Ionbeam Therapycenter MIT, Marburg, Germany
[8] Univ Freiburg, Fac Med, German Canc Res Ctr DKFZ,Dept Radiat Oncol,Div Med, Med Ctr,German Canc Consortium DKTK Partner Site F, Heidelberg, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 04期
关键词
microDiamond; microSilicon; 192Ir; brachytherapy; dosimetry; Monte Carlo simulations; MONTE-CARLO-SIMULATION; IR-192; SOURCE; DOSIMETRY; AAPM; ANISOTROPY; TRANSPORT; WATER; TLD;
D O I
10.1016/j.zemedi.2022.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To employ the microDiamond and the microSilicon detector (mDD and mSD, both PTW-Freiburg, Germany) to determine the dose rate around a HDR 192Ir brachytherapy source (model mHDR-v2r, Elekta AB, Sweden).Methods: The detectors were calibrated with a 60Co beam at the PTW Calibration Laboratory. Measurements around the 192Ir source were performed inside a PTW MP3 water phantom. The detectors were placed at selected points of measure-ment at radial distances r, ranging from 0.5 to 10 cm, keeping the polar angle 0 = 90 degrees. Additional measurements were performed with the mSD at fixed distances r = 1, 3 and 5 cm, with 0 varying from 0 to 150 degrees, 0 to 166 degrees, and 0 to 168 degrees, respectively. The corresponding mDD readings were already available from a previous work (Rossi et al., 2020). The beam quality correction factor of both detectors, as well as a phantom effect correction factor to account for the differ-ence between the experimental geometry and that assumed in the TG-43 formalism, were determined using the Monte Carlo (MC) toolkit EGSnrc. The beam quality correction factor was factorized into energy dependence and volume -averaging correction factors. Using the abovementioned MC-based factors, the dose rate to water at the different points of measurement in TG-43 conditions was obtained from the measured readings, and was compared to the dose rate cal-culated according to the TG-43 formalism.Results: The beam quality correction factor was considerably closer to unity for the mDD than for the mSD. The energy dependence of the mDD showed a very weak radial dependence, similar to the previous findings showing a weak angular dependence as well (Rossi et al., 2020). Conversely, the energy dependence of the mSD decreased significantly with increasing distances, and also showed a considerably more pronounced angular dependence, especially for the smallest angles. The volume-averaging showed a similar radial dependence for both detectors: the correction had a maximal impact at 0.5 cm and then approached unity for larger distances, as expected. Concerning the angular dependence, the correction for the mSD was also similar to the one previously determined for the mDD (Rossi et al., 2020): a maximal impact was observed at 0 = 0 degrees, with values tending to unity for larger angles. In general, the volume-averaging was less pronounced for the mSD due to the smaller sensitive volume radius. After the application of the MC-based factors, dif-ferences between mDD dose rate measurements and TG-43 dose rate calculations ranged from -2.6% to +4.3%, with an absolute average difference of 1.0%. For the mSD, the differences ranged from -3.1% to +5.2%, with an absolute aver-age difference of 1.0%. For both detectors, all differences but one were within the combined uncertainty (k = 2). The dif-ferences of the mSD from the mDD ranged from -3.9% to +2.6%, with the vast majority of them being within the combined uncertainty (k = 2). For 0 - 0 degrees, the mDD was able to provide sufficiently accurate results even without the application of the MC-based beam quality correction factor, with differences to the TG-43 dose rate calculations from -1.9% to +3.4%, always within the combined uncertainty (k = 2).Conclusion: The mDD and the mSD showed consistent results and appear to be well suitable for measuring the dose rate around HDR 192Ir brachytherapy sources. MC characterization of the detectors response is needed to determine the beam quality correction factor and to account for energy dependence and/or volume-averaging, especially for the mSD. Our findings support the employment of the mDD and mSD for source QA, TPS verification and TG-43 parameters determination.
引用
收藏
页码:463 / 478
页数:16
相关论文
共 50 条
  • [1] Employing the microDiamond detector for radial dose function measurements with an 192Ir HDR source
    Rossi, G.
    Gainey, M.
    Thomann, B.
    Kollefrath, M.
    Allgaier, B.
    Wuerfel, J.
    Baltas, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1238 - S1239
  • [2] Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192Ir brachytherapy sources
    Kaveckyte, Vaiva
    Malusek, Alexandr
    Benmakhlouf, Hamza
    Carlsson, Gudrun Alm
    Tedgren, Asa Carlsson
    MEDICAL PHYSICS, 2018, 45 (01) : 429 - 437
  • [3] Determination of transit dose profile for a 192Ir HDR source
    Fonseca, G. P.
    Rubo, R. A.
    Minamisawa, R. A.
    dos Santos, G. R.
    Antunes, P. C. G.
    Yoriyaz, H.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [4] Absorbed dose to water distribution measured around an HDR 192Ir brachytherapy source by thermoluminescent dosimeters
    Aviles Lucas, P.
    Lourenco, V.
    Vermesse, D.
    Cutarella, D.
    Aubineau-Laniece, I.
    METROLOGIA, 2012, 49 (05) : S228 - S230
  • [5] Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors
    Rossi, Giulio
    Gainey, Mark
    Thomann, Benedikt
    Kollefrath, Michael
    Wuerfel, Jan
    Allgaier, Bernd
    Baltas, Dimos
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 272 - 281
  • [6] Audit on source strength determination for HDR and PDR 192Ir brachytherapy in Sweden
    Tedgren, Asa Carlsson
    Grindborg, Jan-Erik
    RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 126 - 130
  • [7] A microDiamondfor determination of absorbed dose around high-dose-rate 192Ir brachytherapy sources
    Kaveckyte, V.
    Malusek, A.
    Benmaklouf, H.
    Carlsson, G. Alm
    Tedgren, A. Carlsson
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S407 - S407
  • [8] A technique for calibrating a high dose rate 192Ir brachytherapy source
    Fourie, O. L.
    Crabtree, T. G.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 85 - 92
  • [9] Monte Carlo angular dose distribution of the microselectron HDR 192Ir brachytherapy source
    Wallace, S.
    Wong, T.
    Fernando, W.
    Australasian Physical and Engineering Sciences in Medicine, 1999, 22 (01): : 1 - 7
  • [10] Dose optimization of breast balloon brachytherapy using a stepping 192Ir HDR source
    Choi, Chang Hyun
    Ye, Sung-Joon
    Parsai, E. Ishmael
    Shen, Sui
    Meredith, Ruby
    Brezovich, Ivan A.
    Ove, Roger
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 90 - 102