Calibration of 192Ir High Dose Rate Brachytherapy Source Using Water Phantom

被引:0
|
作者
Yu, L. [1 ]
Yang, B. [1 ]
Liu, X. [1 ]
Pang, T. [1 ]
Liu, N. [1 ]
Li, B. [1 ]
Dong, T. [1 ]
Wang, B. [1 ]
Wang, Z. [1 ]
Qiu, J. [1 ]
机构
[1] Beijing Union Med Coll Hosp, Beijing, Peoples R China
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-P
引用
收藏
页码:E212 / E212
页数:1
相关论文
共 50 条
  • [21] Quality control of 192Ir High Dose Rate Brachytherapy sources
    Pereira, A
    Pirraco, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S137
  • [22] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [23] Dosimetry Parameters of the IRH10 192Ir High Dose Rate Brachytherapy Source
    Yi, Chul-Young
    Chun, Kook Jin
    Hah, Suck-Ho
    Kim, Hyun-Moon
    Lim, Chunil
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 485 - 492
  • [24] TLD DOSIMETRY OF A NEW 192Ir PULSED DOSE RATE BRACHYTHERAPY SOURCE
    Kabiri, F.
    Sheibani, S.
    Ghozzati, B.
    Beigi, H. Pour
    Javanshir, M.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 45 - 45
  • [25] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Ahn, Woo Sang
    Choi, Wonsik
    Shin, Seong Soo
    Jung, Jinhong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) : 557 - 564
  • [26] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Woo Sang Ahn
    Wonsik Choi
    Seong Soo Shin
    Jinhong Jung
    Journal of the Korean Physical Society, 2014, 65 : 557 - 564
  • [27] Dose Distributions of an 192Ir Brachytherapy Source in Different Media
    Wu, C. H.
    Liao, Y. J.
    Liu, Y. W. Hsueh
    Hung, S. K.
    Lee, M. S.
    Hsu, S. M.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [28] Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors
    Zilio, Valery Olivier
    Joneja, Om Parkash
    Popowski, Youri
    Rosenfeld, Anatoly
    Chawla, Rakesh
    MEDICAL PHYSICS, 2006, 33 (06) : 1532 - 1539
  • [29] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [30] A system for localization of high dose rate 192Ir source during brachytherapy treatment with silicon detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3794 - +