Manual ventilation devices in neonatal resuscitation: Tidal volume and positive pressure-provision

被引:49
|
作者
Roehr, Charles C. [1 ]
Kelm, Marcus [1 ]
Fischer, Hendrik S. [1 ]
Buehrer, Christoph [1 ]
Schmalisch, Gerd [1 ]
Proquitte, Hans [1 ]
机构
[1] Charite, Clin Naonatol, D-10117 Berlin, Germany
关键词
Resuscitation; Neopuff; T-piece resuscitator; Self-inflating bag; Neonate; Preterm; Pressure; VLBW; CPAP; Respiratory function monitor; AIRWAY PRESSURE; LUNG INJURY; GUIDELINES; EQUIPMENT; INFANTS;
D O I
10.1016/j.resuscitation.2009.10.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Excessive peak inspiratory pressures (PIP) and high tidal volumes (Vt) during manual ventilation can be detrimental to the neonatal lung. We compared the influence of different manual ventilation devices and individual professional experience oil the extent of applied Vt and PIP in simulated neonatal resuscitation. Material and methods: One hundred and twenty medical professionals were studied. Ail intubated mannequin (equivalent to 1.0 kg neonate) was ventilated using two different devices: a self-inflating bag and a T-piece resuscitator. Target value was a PIP of 20 cm H2O. Applied PIP and the resulting Vt were recorded continuously using a respiratory function monitor (CO2SMO+, Novametrix, USA). Results: Vt and PIP provision was significantly higher in SI-bags, compared to T-piece devices: median (interquartile range) PIP 25.6 (18.2) cm H2O vs 19.7 (3.2) cm H2O (p < 0.0005), and Vt 5.1(3.2) ml vs Vt 3.6 (0.8) ml (p < 0.0005) respectively. The intersubject variability of Vt and PIP provision was distinctly higher in SI-bags, compared to T-piece devices. Professional experience had no significant impact on the level and the variability of Vt or PIP provided. Conclusion: Use of T-piece devices guarantees reliable and constant Vt and PIP provision, irrespective of individual, operator dependent variables. Methods to measure and to avoid excessive tidal volumes in neonatal resuscitation need to be developed. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:202 / 205
页数:4
相关论文
共 50 条
  • [41] Effects of Imposed Resistance on Tidal Volume With 5 Neonatal Nasal Continuous Positive Airway Pressure Systems
    Cook, Shannon E.
    Fedor, Katherine L.
    Chatburn, Robert L.
    RESPIRATORY CARE, 2010, 55 (05) : 544 - 548
  • [42] Manual positive pressure ventilation and the Copenhagen poliomyelitis epidemic 1952
    Berthelsen, P. G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (05) : 503 - 507
  • [43] The oxygenation ratio during mechanical ventilation in children: The role of tidal volume and positive end-expiratory pressure
    Halbertsma, Feico J. J.
    Vaneker, Michiel
    Pickkers, Peter
    Hoeven, Johannes G.
    JOURNAL OF CRITICAL CARE, 2009, 24 (02) : 220 - 226
  • [44] Nonoperative management of severe tracheobronchial injuries with positive end-expiratory pressure and low tidal volume ventilation
    Self, ML
    Mangram, A
    Berne, JD
    Villarreal, D
    Norwood, S
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (05): : 1072 - 1075
  • [45] Reply to: comparison of low and high positive end-expiratory pressure during low tidal volume ventilation
    Chun, Eun Hee
    Baik, Hee Jung
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (06) : 517 - 518
  • [46] Ventilation devices for neonatal resuscitation at birth: A systematic review and meta-analysis
    Tribolet, Sophie
    Hennuy, Nadege
    Rigo, Vincent
    RESUSCITATION, 2023, 183
  • [47] 958 Different Gas Flow Rates and Effects on Tidal Volume and Mask Leak During Positive Pressure Ventilation
    K Schilleman
    G M Schmölzer
    C O F Kamlin
    A B Te Pas
    C J Morley
    P G Davis
    Pediatric Research, 2010, 68 : 478 - 478
  • [48] Pressure and tidal volume delivery in extremely preterm infants at birth using different t-piece resuscitation devices
    Bresesti, Ilia
    Cavigioli, Francesco
    Scrivens, Alexandra
    Lista, Gianluca
    Chaban, Badr
    Roehr, Charles C.
    Zivanovic, Sanja
    EARLY HUMAN DEVELOPMENT, 2023, 183
  • [49] Tidal volume delivery during nasal intermittent positive pressure ventilation: infant cannula vs. nasal continuous positive airway pressure prongs
    Ashley L. Lynch
    David N. Matlock
    Chary Akmyradov
    Michael D. Weisner
    Jennifer Beck
    Christer Sinderby
    Sherry E. Courtney
    Journal of Perinatology, 2024, 44 : 244 - 249
  • [50] Tidal volume delivery during nasal intermittent positive pressure ventilation: infant cannula vs. nasal continuous positive airway pressure prongs
    Lynch, Ashley L.
    Matlock, David N.
    Akmyradov, Chary
    Weisner, Michael D.
    Beck, Jennifer
    Sinderby, Christer
    Courtney, Sherry E.
    JOURNAL OF PERINATOLOGY, 2024, 44 (02) : 244 - 249