Manual ventilation devices in neonatal resuscitation: Tidal volume and positive pressure-provision

被引:49
|
作者
Roehr, Charles C. [1 ]
Kelm, Marcus [1 ]
Fischer, Hendrik S. [1 ]
Buehrer, Christoph [1 ]
Schmalisch, Gerd [1 ]
Proquitte, Hans [1 ]
机构
[1] Charite, Clin Naonatol, D-10117 Berlin, Germany
关键词
Resuscitation; Neopuff; T-piece resuscitator; Self-inflating bag; Neonate; Preterm; Pressure; VLBW; CPAP; Respiratory function monitor; AIRWAY PRESSURE; LUNG INJURY; GUIDELINES; EQUIPMENT; INFANTS;
D O I
10.1016/j.resuscitation.2009.10.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Excessive peak inspiratory pressures (PIP) and high tidal volumes (Vt) during manual ventilation can be detrimental to the neonatal lung. We compared the influence of different manual ventilation devices and individual professional experience oil the extent of applied Vt and PIP in simulated neonatal resuscitation. Material and methods: One hundred and twenty medical professionals were studied. Ail intubated mannequin (equivalent to 1.0 kg neonate) was ventilated using two different devices: a self-inflating bag and a T-piece resuscitator. Target value was a PIP of 20 cm H2O. Applied PIP and the resulting Vt were recorded continuously using a respiratory function monitor (CO2SMO+, Novametrix, USA). Results: Vt and PIP provision was significantly higher in SI-bags, compared to T-piece devices: median (interquartile range) PIP 25.6 (18.2) cm H2O vs 19.7 (3.2) cm H2O (p < 0.0005), and Vt 5.1(3.2) ml vs Vt 3.6 (0.8) ml (p < 0.0005) respectively. The intersubject variability of Vt and PIP provision was distinctly higher in SI-bags, compared to T-piece devices. Professional experience had no significant impact on the level and the variability of Vt or PIP provided. Conclusion: Use of T-piece devices guarantees reliable and constant Vt and PIP provision, irrespective of individual, operator dependent variables. Methods to measure and to avoid excessive tidal volumes in neonatal resuscitation need to be developed. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:202 / 205
页数:4
相关论文
共 50 条
  • [21] Comparison of positive pressure ventilation devices during compliance changes in a neonatal ovine model
    Tran, Kim Hoang
    Ramsie, Marwa
    Law, Brenda
    Schmolzer, Georg
    PEDIATRIC RESEARCH, 2024, 96 (02) : 332 - 337
  • [22] POSITIVE END-EXPIRATORY PRESSURE - IMPLICATIONS FOR TIDAL VOLUME CHANGES IN ANESTHESIA MACHINE VENTILATION
    ELLIOTT, WR
    HARRIS, AE
    PHILIP, JH
    JOURNAL OF CLINICAL MONITORING, 1989, 5 (02): : 100 - 104
  • [23] Positive End-Expiratory Pressure and Tidal Volume During Initial Ventilation of Preterm Lambs
    Graeme R Polglase
    Noah H Hillman
    J Jane Pillow
    Fook-Choe Cheah
    Ilias Nitsos
    Timothy J M Moss
    Boris W Kramer
    Machiko Ikegami
    Suhas G Kallapur
    Alan H Jobe
    Pediatric Research, 2008, 64 : 517 - 522
  • [24] Positive pressure ventilation during anesthesia in dogs: Assessment of surface area derived tidal volume
    Dyson, Doris H.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2012, 53 (01): : 63 - 66
  • [25] Effect of expiratory positive airway pressure on tidal volume during non-invasive ventilation
    Kinnear, W.
    Watson, L.
    Smith, P.
    Johnson, L.
    Burrows, S.
    Colt, J.
    Sovani, M.
    Khanna, A.
    CHRONIC RESPIRATORY DISEASE, 2017, 14 (02) : 105 - 109
  • [26] EFFECT OF TIDAL VOLUME AND POSITIVE END-EXPIRATORY PRESSURE ON COMPLIANCE DURING MECHANICAL VENTILATION
    SUTER, PM
    FAIRLEY, HB
    ISENBERG, MD
    CHEST, 1978, 73 (02) : 158 - 162
  • [27] Positive End-Expiratory Pressure and Tidal Volume During Initial Ventilation of Preterm Lambs
    Polglase, Graeme R.
    Hillman, Noah H.
    Pillow, J. Jane
    Cheah, Fook-Choe
    Nitsos, Ilias
    Moss, Timothy J. M.
    Kramer, Boris W.
    Ikegami, Machiko
    Kallapur, Suhas G.
    Jobe, Alan H.
    PEDIATRIC RESEARCH, 2008, 64 (05) : 517 - 522
  • [28] Comparison of efficacy of three devices of manual positive pressure ventilation: a mannequin-based study
    Nimbalkar, Somashekhar M.
    Rao, Suman P. N.
    Nesargi, Saudamini V.
    Dongara, Ashish R.
    Bhat, Swarnarekha
    ITALIAN JOURNAL OF PEDIATRICS, 2015, 41
  • [29] Comparison of efficacy of three devices of manual positive pressure ventilation: a mannequin-based study
    Somashekhar M Nimbalkar
    Suman Rao PN
    Saudamini V Nesargi
    Ashish R Dongara
    Swarnarekha Bhat
    Italian Journal of Pediatrics, 41
  • [30] An evaluation of manual tidal volume and respiratory rate delivery during simulated resuscitation
    Scott, J. Brady
    Schneider, Julie M.
    Schneider, Karen
    Li, Jie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 45 : 446 - 450