Manual ventilation devices in neonatal resuscitation: Tidal volume and positive pressure-provision

被引:49
|
作者
Roehr, Charles C. [1 ]
Kelm, Marcus [1 ]
Fischer, Hendrik S. [1 ]
Buehrer, Christoph [1 ]
Schmalisch, Gerd [1 ]
Proquitte, Hans [1 ]
机构
[1] Charite, Clin Naonatol, D-10117 Berlin, Germany
关键词
Resuscitation; Neopuff; T-piece resuscitator; Self-inflating bag; Neonate; Preterm; Pressure; VLBW; CPAP; Respiratory function monitor; AIRWAY PRESSURE; LUNG INJURY; GUIDELINES; EQUIPMENT; INFANTS;
D O I
10.1016/j.resuscitation.2009.10.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Excessive peak inspiratory pressures (PIP) and high tidal volumes (Vt) during manual ventilation can be detrimental to the neonatal lung. We compared the influence of different manual ventilation devices and individual professional experience oil the extent of applied Vt and PIP in simulated neonatal resuscitation. Material and methods: One hundred and twenty medical professionals were studied. Ail intubated mannequin (equivalent to 1.0 kg neonate) was ventilated using two different devices: a self-inflating bag and a T-piece resuscitator. Target value was a PIP of 20 cm H2O. Applied PIP and the resulting Vt were recorded continuously using a respiratory function monitor (CO2SMO+, Novametrix, USA). Results: Vt and PIP provision was significantly higher in SI-bags, compared to T-piece devices: median (interquartile range) PIP 25.6 (18.2) cm H2O vs 19.7 (3.2) cm H2O (p < 0.0005), and Vt 5.1(3.2) ml vs Vt 3.6 (0.8) ml (p < 0.0005) respectively. The intersubject variability of Vt and PIP provision was distinctly higher in SI-bags, compared to T-piece devices. Professional experience had no significant impact on the level and the variability of Vt or PIP provided. Conclusion: Use of T-piece devices guarantees reliable and constant Vt and PIP provision, irrespective of individual, operator dependent variables. Methods to measure and to avoid excessive tidal volumes in neonatal resuscitation need to be developed. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:202 / 205
页数:4
相关论文
共 50 条
  • [1] An evaluation of manual ventilation devices and face masks for neonatal resuscitation
    O'Donnell, CPF
    Davis, PG
    Lau, R
    Dargaville, PA
    Doyle, LW
    Morley, CJ
    PEDIATRIC RESEARCH, 2004, 55 (04) : 455A - 455A
  • [2] Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks
    O'Donnell, CPF
    Davis, PG
    Lau, R
    Dargaville, PA
    Doyle, LW
    Morley, CJ
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2005, 90 (05): : F392 - F396
  • [3] Tidal volume measurements in neonatal pressure control ventilation: Are they meaningful?
    Chow, L
    Vanderhal, A
    Raber, J
    Sola, A
    PEDIATRIC RESEARCH, 1999, 45 (04) : 297A - 297A
  • [4] Tidal Volume Measurements in Neonatal Pressure Control Ventilation: Are They Meaningful?
    Lily Chow
    Andre Vanderhal
    Jorge Raber
    Augusto Sola
    Pediatric Research, 1999, 45 : 297 - 297
  • [5] Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
    Chow, LC
    Vanderhal, A
    Raber, J
    Sola, A
    PEDIATRIC PULMONOLOGY, 2002, 34 (03) : 196 - 202
  • [6] Equipment used for positive pressure ventilation at neonatal resuscitation: An international survey
    O'Donnell, CPF
    Davis, PG
    Morley, CJ
    PEDIATRIC RESEARCH, 2004, 55 (04) : 550A - 550A
  • [7] INSPIRATORY TIME AND TIDAL VOLUME DURING INTERMITTENT POSITIVE PRESSURE VENTILATION
    FIELD, D
    MILNER, AD
    HOPKIN, IE
    ARCHIVES OF DISEASE IN CHILDHOOD, 1985, 60 (03) : 259 - 261
  • [8] A metronome for pacing manual ventilation in a neonatal resuscitation simulation
    Cocucci, Cecilia
    Madorno, Matias
    Aguilar, Adriana
    Acha, Leila
    Szyld, Edgardo
    Musante, Gabriel
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2015, 100 (01): : F47 - F49
  • [9] Positive pressure ventilation at neonatal resuscitation: review of equipment and international survey of practice
    O'Donnell, CPF
    Davis, PG
    Morley, CJ
    ACTA PAEDIATRICA, 2004, 93 (05) : 583 - 588
  • [10] Use of a manometer during positive pressure ventilation at neonatal resuscitation: Help or hindrance?
    O'Donnell, CPF
    Davis, PG
    Lau, R
    Dargaville, PA
    Doyle, LW
    Morley, CJ
    PEDIATRIC RESEARCH, 2004, 55 (04) : 550A - 551A