Rod-like CuO nanoparticles/waste masks carbon modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-cancer drug pazopanib in biological and pharmaceutical samples

被引:26
|
作者
Bilge, Selva [1 ]
Dogan-Topal, Burcu [2 ]
Atici, Esen Bellur [3 ]
Sinag, Ali [1 ]
Ozkan, Sibel A. [2 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, Ankara, Turkey
[2] Ankara Univ, Fac Pharm, Dept Analyt Chem, Ankara, Turkey
[3] DEVA Holding AS, R&D Ctr, Karaagac Mh Fatih Blv 26, TR-59510 Kapakh, Tekirdag, Turkey
关键词
Nanosensor; Electrooxidation; Pazopanib; Hydrothermal carbonization; Waste masks; Rod-like CuO nanoparticles;
D O I
10.1016/j.snb.2021.130109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, the first voltammetric method is developed for the detection of pazopanib (PZB), a pharmaceutically active ingredient belonging to the tyrosine kinase inhibitor class, using a modified glassy carbon electrode (GCE). Rod-like CuO nanoparticles synthesized by hydrothermal method and finger-like carbon material obtained from hydrothermal carbonization (HTC) of waste masks (M) were used as modification agents. The chemical structure and surface morphology of the synthesized materials were elucidated using various analytical techniques. The results show that carbon material has a core-shell structure, a critical property that increases electrical conductivity. Thus, the effects of both nanoparticles and carbon material on the electrooxidation behavior of pazopanib were investigated and compared. The effect of scan rate, pH, and supporting electrolyte on the voltammetric response of pazopanib was investigated on bare and modified GCE. The possible electrochemical oxidation mechanism was discussed with model drugs on bare GCE. The electrooxidation of PZB was an adsorption-controlled process on modified GCE at pH 7.0 phosphate buffer solution as proved by cyclic voltammetry (CV). All parameters of stripping conditions and square wave voltammetry (SWV) were optimized. The calibration curve was linear in the range of 2.0 x 10-10-1.0 x 10-6 M by adsorptive stripping square wave voltammetry (AdSSWV). The proposed method was used for the quantification of pazopanib in human serum samples and pharmaceutical dosage forms with satisfactory precision and accuracy. The method showed excellent analytical performance at nano- detection levels. Besides, the nanosensor was tested in the presence of some interfering compounds and ions.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Application of a glassy carbon electrode modified with carbon black nanoparticles for highly sensitive voltammetric determination of quetiapine
    Lawrywianiec, M.
    Smajdor, J.
    Paczosa-Bator, B.
    Piech, R.
    ANALYTICAL METHODS, 2017, 9 (47) : 6662 - 6668
  • [12] A novel voltammetric sensor based on palladium nanoparticles/carbon nanofibers/ionic liquid modified carbon paste electrode for sensitive determination of anti-cancer drug pemetrexed
    Afzali, Moslem
    Mostafavi, Ali
    Nekooie, Reyhaneh
    Jahromi, Zahra
    JOURNAL OF MOLECULAR LIQUIDS, 2019, 282 : 456 - 465
  • [13] A Sensitive Determination of Acetaminophen in Pharmaceutical Preparations and Biological Samples using Multi-Walled Carbon Nanotube Modified Glassy Carbon Electrode
    Babaei, Ali
    Afrasiabi, Mohammad
    Mirzakhani, Somaieh
    Taheri, Ali Reza
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (02) : 344 - 351
  • [14] Electrochemical Determination of Anti-Cancer Drug Pazopanib with High Selectivity and Sensitivity Using Molecularly Imprinted Polymer-Modified Glassy Carbon Electrode
    Samanci, Seyda Nur
    Cetinkaya, Ahmet
    Doufene, Nassim
    Bounoua, Nadia
    Kaya, S. Irem
    Atici, Esen Bellur
    Ozkan, Sibel A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (03)
  • [15] Highly sensitive voltammetric determination of hydrochlorothiazide using a glassy carbon electrode modified with Super P carbon black nanoparticles
    Santos-Neto, Domingos R.
    Lopes, Carlos E. C.
    Silva, Gabrielly P.
    Castro, Lizandra N.
    Silva, Joao Pedro C.
    Ferreira, Dianderson C. M.
    Silva, Luiz Ricardo G.
    Dantas, Luiza M. F.
    da Silva, Iranaldo S.
    ANALYTICAL METHODS, 2024, 16 (36) : 6271 - 6278
  • [16] Sensitive voltammetric determination of riboflavin in pharmaceutical and biological samples using FSN-Zonyl-Nafion modified carbon paste electrode
    Stefanov, Cristina
    Negut, Catalina Cioates
    Gugoasa, Livia Alexandra Dinu
    van Staden, Jacobus Frederick
    MICROCHEMICAL JOURNAL, 2020, 155
  • [17] Bilayered Film Modified Glassy Carbon Electrode for the Simultaneous Determination of Paracetamol and Chloroquine in Pharmaceutical and Biological Samples
    Gashu, Mulu
    Aragaw, Belete Asefa
    Tefera, Molla
    Abebe, Atakilt
    ACS OMEGA, 2025, 10 (06): : 5601 - 5615
  • [18] Development of a sensitive voltammetric sensor for diltiazem determination in biological samples using MWCNT/PPy-PBA modified glassy carbon electrode
    Ostovar, Sahar
    Maghsoudi, Shahab
    Mousavi, Mehdi
    SYNTHETIC METALS, 2021, 281
  • [19] Benzoylferrocene-modified carbon nanotubes paste electrode as a voltammetric sensor for determination of hydrochlorothiazide in pharmaceutical and biological samples
    Hadi Beitollahi
    Farzaneh Ghorbani
    Ionics, 2013, 19 : 1673 - 1679
  • [20] Voltammetric determination of rivastigmine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode
    Arvand, Majid
    Fallahi, Parisa
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 797 - 805