Rod-like CuO nanoparticles/waste masks carbon modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-cancer drug pazopanib in biological and pharmaceutical samples

被引:26
|
作者
Bilge, Selva [1 ]
Dogan-Topal, Burcu [2 ]
Atici, Esen Bellur [3 ]
Sinag, Ali [1 ]
Ozkan, Sibel A. [2 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, Ankara, Turkey
[2] Ankara Univ, Fac Pharm, Dept Analyt Chem, Ankara, Turkey
[3] DEVA Holding AS, R&D Ctr, Karaagac Mh Fatih Blv 26, TR-59510 Kapakh, Tekirdag, Turkey
关键词
Nanosensor; Electrooxidation; Pazopanib; Hydrothermal carbonization; Waste masks; Rod-like CuO nanoparticles;
D O I
10.1016/j.snb.2021.130109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, the first voltammetric method is developed for the detection of pazopanib (PZB), a pharmaceutically active ingredient belonging to the tyrosine kinase inhibitor class, using a modified glassy carbon electrode (GCE). Rod-like CuO nanoparticles synthesized by hydrothermal method and finger-like carbon material obtained from hydrothermal carbonization (HTC) of waste masks (M) were used as modification agents. The chemical structure and surface morphology of the synthesized materials were elucidated using various analytical techniques. The results show that carbon material has a core-shell structure, a critical property that increases electrical conductivity. Thus, the effects of both nanoparticles and carbon material on the electrooxidation behavior of pazopanib were investigated and compared. The effect of scan rate, pH, and supporting electrolyte on the voltammetric response of pazopanib was investigated on bare and modified GCE. The possible electrochemical oxidation mechanism was discussed with model drugs on bare GCE. The electrooxidation of PZB was an adsorption-controlled process on modified GCE at pH 7.0 phosphate buffer solution as proved by cyclic voltammetry (CV). All parameters of stripping conditions and square wave voltammetry (SWV) were optimized. The calibration curve was linear in the range of 2.0 x 10-10-1.0 x 10-6 M by adsorptive stripping square wave voltammetry (AdSSWV). The proposed method was used for the quantification of pazopanib in human serum samples and pharmaceutical dosage forms with satisfactory precision and accuracy. The method showed excellent analytical performance at nano- detection levels. Besides, the nanosensor was tested in the presence of some interfering compounds and ions.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Simultaneous voltammetric determination of tramadol and paracetamol exploiting glassy carbon electrode modified with FeNi3 nanoalloy in biological and pharmaceutical media
    Hajmalek, Saeed
    Jahani, Shohreh
    Foroughi, Mohammad Mehdi
    CHEMISTRYSELECT, 2021, 6 (33): : 8797 - 8808
  • [32] Voltammetric Determination of Dicyclomine Hydrochloride by Carbon Paste Electrode Modified with Iron (III) Oxide Nanoparticles and Activated Glassy Carbon Electrode in Pharmaceutical Dosage Form, Human Plasma and Urine
    Abou Al Alamein, Amal M.
    Hendawy, Hassan A. M.
    Elabd, Nourhan O.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7989 - 8005
  • [33] Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
    Kassa, Adane
    Amare, Meareg
    Benor, Amare
    Tigineh, Getinet Tamiru
    Beyene, Yonas
    Tefera, Molla
    Abebe, Atakilt
    ACS OMEGA, 2022, : 34599 - 34607
  • [34] Adsorptive stripping voltammetric determination of dicyclomine hydrochloride at a glassy carbon electrode modified with silver decorated Fe3O4 nanocubes in pharmaceutical and biological samples
    Rawool, Chaitali R.
    Rajpurohit, Anuja S.
    Punde, Ninad S.
    Srivastava, Ashwini K.
    ANALYTICAL METHODS, 2018, 10 (12) : 1441 - 1451
  • [35] Voltammetric determination of the anti-cancer drug nilutamide using a screen-printed carbon electrode modified with a composite prepared from β-cyclodextrin, gold nanoparticles and graphene oxide
    Raj Karthik
    Natarajan Karikalan
    Shen-Ming Chen
    Periyasami Gnanaprakasam
    Chelladurai Karuppiah
    Microchimica Acta, 2017, 184 : 507 - 514
  • [36] Voltammetric determination of the anti-cancer drug nilutamide using a screen-printed carbon electrode modified with a composite prepared from β-cyclodextrin, gold nanoparticles and graphene oxide
    Karthik, Raj
    Karikalan, Natarajan
    Chen, Shen-Ming
    Gnanaprakasam, Periyasami
    Karuppiah, Chelladurai
    MICROCHIMICA ACTA, 2017, 184 (02) : 507 - 514
  • [37] Polymer Modified Carbon Paste Electrode as a Sensitive Sensor for the Electrochemical Determination of Riboflavin and Its Application in Pharmaceutical and Biological Samples
    D'Souza, Edwin S.
    Manjunatha, J. G.
    Raril, C.
    Tigari, Girish
    Pushpanjali, P. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (04): : 461 - 472
  • [38] DETERMINATION OF ANTI-CANCER DRUG EMODIN USING A SILICA-GEL-MODIFIED CARBON PASTE ELECTRODE
    Vu, Dai Long
    Ertek, Bensu
    Dilgin, Yusuf
    Cervenka, Libor
    QUIMICA NOVA, 2014, 37 (10): : 1629 - 1632
  • [39] Determination of prednisolone, dexamethasone and hydrocortisone in pharmaceutical formulations and biological fluid samples by voltammetric techniques using β-cyclodextrin modified carbon paste electrode
    Balaji, K.
    Reddy, G. V. Raghunadha
    Reddy, T. Madhusudana
    Reddy, S. Jayarama
    AFRICAN JOURNAL OF PHARMACY AND PHARMACOLOGY, 2008, 2 (08): : 157 - 166
  • [40] Preparation of a glassy carbon electrode modified with saffron conjugated silver nanoparticles for the sensitive and selective electroanalytical determination of amoxicillin in urine samples
    Sarakatsanou, Christina
    Karastogianni, Sophia
    Girousi, Stella
    ANALYTICAL METHODS, 2023, 15 (35) : 4572 - 4581