Voltammetric determination of rivastigmine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode

被引:26
|
作者
Arvand, Majid [1 ]
Fallahi, Parisa [1 ]
机构
[1] Univ Guilan, Fac Sci, Dept Chem, Rasht, Iran
关键词
Molecularly imprinted polymer (MIP); Voltammetric sensor; Carbon paste modified electrode; Rivastigmine; TAGUCHI OPTIMIZATION METHODOLOGY; PYROLYTIC-GRAPHITE ELECTRODE; TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL SENSOR; POTENTIOMETRIC SENSOR; HYDROGEN TARTRATE; HUMAN PLASMA; FLUIDS;
D O I
10.1016/j.snb.2013.07.092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Despite the increasing number of applications of molecularly imprinted polymers (MIPs) in analytical chemistry, the construction of a biomimetic voltammetric sensor remains still challenging. A new voltammetric sensor for rivastigmine (RIV) measurement is introduced. A RIV-selective molecularly imprinted polymer and a non-imprinted polymer (NIP) were synthesized in a non-covalent approach using methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as crosslinking monomer via a free radical polymerization and then were used for carbon paste electrode (CPE) preparation. The electrochemical behavior of the sensor toward RIV was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The MIP embedded in the CPE, functioned as a selective recognition element and a pre-concentrator agent for RIV determination. The MIP-CPE showed very high recognition ability in comparison to NIP-CPE. The complete removal of RIV from polymer was confirmed by FTIR and TGA. Some parameters affecting sensor response were optimized, and a calibration curve was then plotted. A linear range of 2.0-1000 timol L-1 was obtained. The detection limit of the sensor was calculated to be equal to 0.44 timol L-1. This sensor was used successfully for RIV determination in capsule and spiked serum and urine samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:797 / 805
页数:9
相关论文
共 50 条
  • [1] Electroanalytical determination of sulfasalazine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode
    Sadeghi, Susan
    Motaharian, Ali
    Moghaddam, Ali Zeraatkar
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 336 - 344
  • [2] Voltammetric Determination of Valaciclovir Using a Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    El Gohary, Nesrine Abdelrehim
    Madbouly, Adel
    El Nashar, Rasha Mohamed
    Mizaikoff, Boris
    ELECTROANALYSIS, 2017, 29 (05) : 1388 - 1399
  • [3] Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Motghare, Ramani V.
    Tadi, Kiran Kumar
    Dhawale, Payal
    Deotare, Samiksha
    Kawadkar, Aruna K.
    Chillawar, Rakesh
    Khan, Shirinaz
    ELECTROANALYSIS, 2015, 27 (03) : 825 - 832
  • [4] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Sara Dehdashtian
    Beshare Hashemi
    Chemical Papers, 2020, 74 : 157 - 165
  • [5] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Dehdashtian, Sara
    Hashemi, Beshare
    CHEMICAL PAPERS, 2020, 74 (01): : 157 - 165
  • [6] Selective and sensitive voltammetric sensor for methocarbamol determination by molecularly imprinted polymer modified carbon paste electrode
    Payehghadr, Mahmood
    Taherkhani, Yeganeh
    Maleki, Abbas
    Nourifard, Farzaneh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (09): : 982 - 990
  • [7] Voltammetric determination of lactic acid in milk samples using carbon paste electrode modified with chitosan-based magnetic molecularly imprinted polymer
    Zohre Mahmoudi
    Javad Tashkhourian
    Bahram Hemmateenejad
    Journal of Applied Electrochemistry, 2022, 52 : 35 - 44
  • [8] Voltammetric determination of lactic acid in milk samples using carbon paste electrode modified with chitosan-based magnetic molecularly imprinted polymer
    Mahmoudi, Zohre
    Tashkhourian, Javad
    Hemmateenejad, Bahram
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2022, 52 (01) : 35 - 44
  • [9] Copper(II) determination by using carbon paste electrode modified with molecularly imprinted polymer
    Wang Zhihua
    Liu Xiaole
    Yang Jianming
    Qin Yaxin
    Lu Xiaoquan
    ELECTROCHIMICA ACTA, 2011, 58 : 750 - 756
  • [10] In Situ Voltammetric Determination of Promethazine on Carbon Paste Electrode Modified with Nano-sized Molecularly Imprinted Polymer
    Akhoundian, Maedeh
    Alizadeh, Taher
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (07): : 1014 - 1024