Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode

被引:23
|
作者
Motghare, Ramani V. [1 ]
Tadi, Kiran Kumar [1 ]
Dhawale, Payal [1 ]
Deotare, Samiksha [2 ]
Kawadkar, Aruna K. [3 ]
Chillawar, Rakesh [1 ]
Khan, Shirinaz [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Chem, Nagpur 440010, Maharashtra, India
[2] Govt Med Coll, Nagpur 440011, Maharashtra, India
[3] Inst Sci, Dept Zool, Nagpur 440011, Maharashtra, India
关键词
Computational chemistry; Stripping voltammetry; Electrochemical sensors; Molecularly imprinted polymer; Carbon paste electrode; Uric acid; ASCORBIC-ACID; GLASSY-CARBON; FOLIC-ACID; ELECTROCHEMICAL SENSOR; FILM; ALLANTOIN; PLASMA;
D O I
10.1002/elan.201400579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecularly imprinted polymer (MIP) for uric acid (UA) was synthesized by thermal polymerization using acrylic acid (AA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross linker and 2,2-azobis(2-isobutyro) nitrile (AIBN) as initiator. The noncovalent interactions involved in four possible conformations of pre-polymer complex were computationally studied by density functional theory. The hydrogen bond formation between UA and AA was confirmed by Fourier transform infrared (FTIR) spectrum of the MIP before extraction of UA. After extraction of the template, the molecularly imprinted polymer based carbon paste electrode (MIPCPE) was fabricated under optimized conditions. A significant enhancement in the electrocatalytic oxidation of UA was found at MIPCPE. The electrochemical behavior of sensor was investigated by cyclic voltammetry (CV) and differential pulse adsorptive stripping voltammetry (DPAdSV). The electrochemical impedance spectroscopy (EIS) studies revealed less charge transfer resistance (R-ct) at MIPCPE than NIPCPE. Under optimized conditions, calibration curve was obtained with a linearity range of 0.5 mu M to 100 mu M and the limit of detection was 0.1 mu M. The sensor showed good selectivity towards UA in the presence of interferents and was successfully applied for the determination of UA in spiked serum samples.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 50 条
  • [1] Voltammetric Determination of Valaciclovir Using a Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    El Gohary, Nesrine Abdelrehim
    Madbouly, Adel
    El Nashar, Rasha Mohamed
    Mizaikoff, Boris
    ELECTROANALYSIS, 2017, 29 (05) : 1388 - 1399
  • [2] Selective and sensitive voltammetric sensor for methocarbamol determination by molecularly imprinted polymer modified carbon paste electrode
    Payehghadr, Mahmood
    Taherkhani, Yeganeh
    Maleki, Abbas
    Nourifard, Farzaneh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (09): : 982 - 990
  • [3] In Situ Voltammetric Determination of Promethazine on Carbon Paste Electrode Modified with Nano-sized Molecularly Imprinted Polymer
    Akhoundian, Maedeh
    Alizadeh, Taher
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (07): : 1014 - 1024
  • [4] Voltammetric determination of rivastigmine in pharmaceutical and biological samples using molecularly imprinted polymer modified carbon paste electrode
    Arvand, Majid
    Fallahi, Parisa
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 797 - 805
  • [5] Voltammetric determination of lactic acid in milk samples using carbon paste electrode modified with chitosan-based magnetic molecularly imprinted polymer
    Zohre Mahmoudi
    Javad Tashkhourian
    Bahram Hemmateenejad
    Journal of Applied Electrochemistry, 2022, 52 : 35 - 44
  • [6] Voltammetric determination of lactic acid in milk samples using carbon paste electrode modified with chitosan-based magnetic molecularly imprinted polymer
    Mahmoudi, Zohre
    Tashkhourian, Javad
    Hemmateenejad, Bahram
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2022, 52 (01) : 35 - 44
  • [7] Electrochemical Determination of Moxifloxacin Hydrochloride Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Zhou, Qing
    Long, Ning
    Liu, Lan
    Zhai, Haiyun
    Zhu, Mingfang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (06): : 5069 - 5076
  • [8] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Sara Dehdashtian
    Beshare Hashemi
    Chemical Papers, 2020, 74 : 157 - 165
  • [9] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Dehdashtian, Sara
    Hashemi, Beshare
    CHEMICAL PAPERS, 2020, 74 (01): : 157 - 165
  • [10] Copper(II) determination by using carbon paste electrode modified with molecularly imprinted polymer
    Wang Zhihua
    Liu Xiaole
    Yang Jianming
    Qin Yaxin
    Lu Xiaoquan
    ELECTROCHIMICA ACTA, 2011, 58 : 750 - 756