Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode

被引:23
|
作者
Motghare, Ramani V. [1 ]
Tadi, Kiran Kumar [1 ]
Dhawale, Payal [1 ]
Deotare, Samiksha [2 ]
Kawadkar, Aruna K. [3 ]
Chillawar, Rakesh [1 ]
Khan, Shirinaz [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Chem, Nagpur 440010, Maharashtra, India
[2] Govt Med Coll, Nagpur 440011, Maharashtra, India
[3] Inst Sci, Dept Zool, Nagpur 440011, Maharashtra, India
关键词
Computational chemistry; Stripping voltammetry; Electrochemical sensors; Molecularly imprinted polymer; Carbon paste electrode; Uric acid; ASCORBIC-ACID; GLASSY-CARBON; FOLIC-ACID; ELECTROCHEMICAL SENSOR; FILM; ALLANTOIN; PLASMA;
D O I
10.1002/elan.201400579
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecularly imprinted polymer (MIP) for uric acid (UA) was synthesized by thermal polymerization using acrylic acid (AA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross linker and 2,2-azobis(2-isobutyro) nitrile (AIBN) as initiator. The noncovalent interactions involved in four possible conformations of pre-polymer complex were computationally studied by density functional theory. The hydrogen bond formation between UA and AA was confirmed by Fourier transform infrared (FTIR) spectrum of the MIP before extraction of UA. After extraction of the template, the molecularly imprinted polymer based carbon paste electrode (MIPCPE) was fabricated under optimized conditions. A significant enhancement in the electrocatalytic oxidation of UA was found at MIPCPE. The electrochemical behavior of sensor was investigated by cyclic voltammetry (CV) and differential pulse adsorptive stripping voltammetry (DPAdSV). The electrochemical impedance spectroscopy (EIS) studies revealed less charge transfer resistance (R-ct) at MIPCPE than NIPCPE. Under optimized conditions, calibration curve was obtained with a linearity range of 0.5 mu M to 100 mu M and the limit of detection was 0.1 mu M. The sensor showed good selectivity towards UA in the presence of interferents and was successfully applied for the determination of UA in spiked serum samples.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 50 条
  • [31] Determination of Bisphenol A Using an Electrochemical Sensor Based on a Molecularly Imprinted Polymer-Modified Multiwalled Carbon Nanotube Paste Electrode
    Chen, Zhidong
    Tang, Chuangui
    Zeng, Yanbo
    Liu, Haiqing
    Yin, Zhengzhi
    Li, Lei
    ANALYTICAL LETTERS, 2014, 47 (06) : 996 - 1014
  • [32] RETRACTED: Development of carbon paste electrodes modified by molecularly imprinted polymer as potentiometry sensor of uric acid (Retracted Article)
    Khasanah, Miratul
    Darmokoesoemo, Handoko
    Widayanti, Nesti
    Kadmi, Yassine
    Elmsellem, Hicham
    Kusuma, Heri Septya
    RESULTS IN PHYSICS, 2017, 7 : 1833 - 1844
  • [33] A novel high selective and sensitive metronidazole voltammetric sensor based on a molecularly imprinted polymer-carbon paste electrode
    Gholivand, Mohammad Bagher
    Torkashvand, Maryam
    TALANTA, 2011, 84 (03) : 905 - 912
  • [34] Development of a selective and sensitive voltammetric sensor for propylparaben based on a nanosized molecularly imprinted polymer-carbon paste electrode
    Gholivand, Mohammad Bagher
    Shamsipur, Mojtaba
    Dehdashtian, Sara
    Rajabi, Hamid Reza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 36 : 102 - 107
  • [35] Simultaneous Voltammetric Determination of Norepinephrine, Uric Acid and Folic Acid at the Surface of Modified Chloranil Carbon Nanotube Paste Electrode
    Yaghoubian, Halimeh
    Soltani-Nejad, Vahhab
    Roodsaz, Sara
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (10): : 1411 - 1421
  • [36] Thiosemicarbazide Poly(paraphenylenediamine) Fastened on Modified Carbon Paste Electrode Advancing Voltammetric Determination of Dopamine and Uric Acid
    Gupta, B. Sreenatha
    Kumar, A. Anil
    Vallabhaneni, Madhusudhan Rao
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2024, 16 (02): : 126 - 141
  • [37] Carbon Paste Electrode Modified Molecularly Imprinted Polymer as a Sensor for Creatinine Analysis by Stripping Voltammetry
    Khasanah, M.
    Darmokoesoemo, H.
    Rizki, D. A.
    6TH INTERNATIONAL CONFERENCE AND WORKSHOPS ON BASIC AND APPLIES SCIENCES, 2017, 1888
  • [38] Carbon paste electrode modified with duplex molecularly imprinted polymer hybrid film for metronidazole detection
    Xiao, Ni
    Deng, Jian
    Cheng, Jianlin
    Ju, Saiqin
    Zhao, Haiqing
    Xie, Jin
    Qian, Duo
    He, Jun
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 54 - 60
  • [39] Development of uric acid sensor based on molecularly imprinted polymer-modified hanging mercury drop electrode
    Lakshmi, Dhana
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    ELECTROANALYSIS, 2006, 18 (09) : 918 - 927
  • [40] High Selective Parathion Voltammetric Sensor Development by Using an Acrylic Based Molecularly Imprinted Polymer-Carbon Paste Electrode
    Alizadeh, Taher
    ELECTROANALYSIS, 2009, 21 (13) : 1490 - 1498