A modified projection reconstruction trajectory for reduction of undersampling artifacts

被引:1
|
作者
Wang, WT
Grimm, RC
Riederer, SJ
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
projection reconstruction; undersampling artifacts; magnetic resonance imaging; PSF; k-space;
D O I
10.1002/jmri.20248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reduce undersampling artifacts for a given number of repetitions of the projection reconstruction (PR) sequence by modifying its k-space trajectory to sample more mid-frequencies while reducing the sampling coverage of the peripheral spatial frequencies. Materials and Methods: The single k-space spoke measured per repetition in the standard PR was modified so that one complete and two partial spokes were measured per repetition but with decreased k-space extent. The point spread functions (PSFs) and undersampling artifacts of the modified PR were compared with those of the standard PR for various numbers of projections. Phantom and in vivo images were used to assess the relative performance. Results: PSF analysis indicated that the modified PR method provided reduced undersampling artifacts with somewhat reduced spatial resolution. The phantom and in vivo images corroborated this. Conclusion: The modified PR trajectory provides reduced undersampling artifact vs. the standard PR. particularly when the number of projections is limited and the artifact level is high.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [41] Metal artifacts reduction in x-ray CT based on segmentation and forward-projection
    Nawaz, Shoukat
    Fu, Jian
    Fan, Dekai
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 3287 - 3293
  • [42] Accelerating Ring Artifacts Reduction for Cone Beam CT Based on Projection Data using CUDA
    Mao, Baolin
    Xiao, Dayu
    Xiong, Xin
    Chen, Xiaozhao
    Zhang, Wei
    Kang, Yan
    PROCEEDINGS OF 2013 IEEE INTERNATIONAL CONFERENCE ON MEDICAL IMAGING PHYSICS AND ENGINEERING (ICMIPE), 2013, : 30 - 33
  • [43] Comparison of three undersampling approaches in computed tomography reconstruction
    Shen, Chenyang
    Lou, Yifei
    Chen, Liyuan
    Zeng, Tieyong
    Ng, Michael K.
    Zhu, Lei
    Jia, Xun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (07) : 1229 - +
  • [44] Stochastic Oscillation Undersampling to Reduce Frequency Aliasing Artifacts in the Magnetic Resonance Imaging
    Wang, Wei
    Cao, Ning
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (04) : 750 - 756
  • [45] Simply denoise: Wavefield reconstruction via jittered undersampling
    Hennenfent, Gilles
    Herrmann, Felix J.
    GEOPHYSICS, 2008, 73 (03) : V19 - V28
  • [46] JOINT LEARNING OF CARTESIAN UNDERSAMPLING AND RECONSTRUCTION FOR ACCELERATED MRI
    Weiss, Tomer
    Vedula, Sanketh
    Senouf, Ortal
    Michailovich, Oleg
    Zibulevsky, Michael
    Bronstein, Alex
    2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 8653 - 8657
  • [47] A NOISE REDUCTION METHOD FOR IMU AND ITS APPLICATION ON HANDWRITING TRAJECTORY RECONSTRUCTION
    Pan, Tse-Yu
    Kuo, Chih-Hsuan
    Hu, Min-Chun
    2016 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA & EXPO WORKSHOPS (ICMEW), 2016,
  • [48] An improved manifold-projection trajectory based method for chemical kinetic mechanism reduction
    Li, Yuqiang
    Lin, Shoulong
    Zhou, Xueming
    Wu, Gang
    CHEMICAL ENGINEERING SCIENCE, 2024, 298
  • [49] A New Susceptibility-Weighted Image Reconstruction Method for the Reduction of Background Phase Artifacts
    Lee, Yoojin
    Han, Yeji
    Park, HyunWook
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1324 - 1335
  • [50] Modified Tensor Locality Preserving Projection for Dimensionality Reduction of Hyperspectral Images
    Deng, Yang-Jun
    Li, Heng-Chao
    Pan, Lei
    Shao, Li-Yang
    Du, Qian
    Emery, William J.
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2018, 15 (02) : 277 - 281