A modified projection reconstruction trajectory for reduction of undersampling artifacts

被引:1
|
作者
Wang, WT
Grimm, RC
Riederer, SJ
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
projection reconstruction; undersampling artifacts; magnetic resonance imaging; PSF; k-space;
D O I
10.1002/jmri.20248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reduce undersampling artifacts for a given number of repetitions of the projection reconstruction (PR) sequence by modifying its k-space trajectory to sample more mid-frequencies while reducing the sampling coverage of the peripheral spatial frequencies. Materials and Methods: The single k-space spoke measured per repetition in the standard PR was modified so that one complete and two partial spokes were measured per repetition but with decreased k-space extent. The point spread functions (PSFs) and undersampling artifacts of the modified PR were compared with those of the standard PR for various numbers of projections. Phantom and in vivo images were used to assess the relative performance. Results: PSF analysis indicated that the modified PR method provided reduced undersampling artifacts with somewhat reduced spatial resolution. The phantom and in vivo images corroborated this. Conclusion: The modified PR trajectory provides reduced undersampling artifact vs. the standard PR. particularly when the number of projections is limited and the artifact level is high.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [31] Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completiond
    Lemmens, Catherine
    Faul, David
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (02) : 250 - 260
  • [32] 3D Target Trajectory Reconstruction Using CBCT Projection Images
    Cho, B.
    Ahn, W.
    Yoon, S.
    Kim, J.
    Poulsen, P.
    Keall, P.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [33] Nature of ringing artifacts in SPECT reconstruction and their reduction by the use of side information
    Li, Jia
    Koral, Kenneth F.
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 181 - +
  • [34] Superiorized polyenergetic reconstruction algorithm for reduction of metal artifacts in CT images
    Humphries, T.
    Gibali, A.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [35] Improving Electrical Impedance Tomography Reconstruction Algorithms By The Reduction Of Movement Artifacts
    Robijns, F.
    Kneyber, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [36] Projection-based metal artifacts reduction in CT images via nonlinear weights
    Gu, Jianwei
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2006, 46 (06): : 825 - 828
  • [37] Reduction of CT artifacts caused by metallic hip implants with maximum intensity projection (MIP)
    Minoui, A
    Chevrot, A
    Godefroy, D
    Drape, J
    Sarazin, LR
    Pessis, EG
    RADIOLOGY, 1997, 205 : 1499 - 1499
  • [38] Incomplete projection reconstruction of computed tomography based on the modified discrete algebraic reconstruction technique
    Yang, Fuqiang
    Zhang, Dinghua
    Huang, Kuidong
    Gao, Zongzhao
    Yang, YaFei
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (02)
  • [39] Comparative studies on algorithms for metal artifacts reduction in CT image reconstruction (WIP)
    Xia, D
    Yu, L
    Pan, X
    Roeske, J
    Pelizzari, C
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408
  • [40] Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT
    Boudabbous, Sana
    Arditi, Daniel
    Paulin, Emilie
    Syrogiannopoulou, Aphrodite
    Becker, Christoph
    Montet, Xavier
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : 380 - 385