A modified projection reconstruction trajectory for reduction of undersampling artifacts

被引:1
|
作者
Wang, WT
Grimm, RC
Riederer, SJ
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
projection reconstruction; undersampling artifacts; magnetic resonance imaging; PSF; k-space;
D O I
10.1002/jmri.20248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reduce undersampling artifacts for a given number of repetitions of the projection reconstruction (PR) sequence by modifying its k-space trajectory to sample more mid-frequencies while reducing the sampling coverage of the peripheral spatial frequencies. Materials and Methods: The single k-space spoke measured per repetition in the standard PR was modified so that one complete and two partial spokes were measured per repetition but with decreased k-space extent. The point spread functions (PSFs) and undersampling artifacts of the modified PR were compared with those of the standard PR for various numbers of projections. Phantom and in vivo images were used to assess the relative performance. Results: PSF analysis indicated that the modified PR method provided reduced undersampling artifacts with somewhat reduced spatial resolution. The phantom and in vivo images corroborated this. Conclusion: The modified PR trajectory provides reduced undersampling artifact vs. the standard PR. particularly when the number of projections is limited and the artifact level is high.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [21] Optimized Reconstruction Procedure of Photoacoustic Imaging for Reflection Artifacts Reduction
    Qi, Yuexin
    Cao, Hui
    Yin, Guanjun
    Zhang, Beilei
    Guo, Jianzhong
    ULTRASONIC IMAGING, 2022, 44 (5-6) : 204 - 212
  • [22] Modified Back Projection Reconstruction for Circular FMCW SAR
    Jia, Gaowei
    Chang, Wenge
    2014 INTERNATIONAL RADAR CONFERENCE (RADAR), 2014,
  • [23] PROJECTION RECONSTRUCTION TECHNIQUES FOR REDUCTION OF MOTION EFFECTS IN MRI
    GLOVER, GH
    PAULY, JM
    MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 275 - 289
  • [24] Reduction of noise and image artifacts in computed tomography by nonlinear filtration of the projection images
    Demirkaya, O
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 917 - 923
  • [25] CONSISTENT PROJECTION RECONSTRUCTION FOR ARTIFACT REDUCTION IN MR IMAGING
    GLOVER, GH
    RADIOLOGY, 1992, 185 : 222 - 222
  • [26] Detail reconstruction in ghost imaging with undersampling
    Jiang, Teng
    Tan, Wei
    Huang, Xianwei
    Nan, Suqin
    Bai, Yanfeng
    Fu, Xiquan
    JOURNAL OF OPTICS, 2021, 23 (07)
  • [27] Mathematical Reduction of Artifacts in Limited Projection and Limited Angle Cone Beam CT
    Wei, Y.
    Gersh, J.
    Mckee, M.
    Baydush, A.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints
    Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, United States
    MED. PHYS., 2 (251-262):
  • [30] Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints
    Gai, N
    Axel, L
    MEDICAL PHYSICS, 1996, 23 (02) : 251 - 262