A modified projection reconstruction trajectory for reduction of undersampling artifacts

被引:1
|
作者
Wang, WT
Grimm, RC
Riederer, SJ
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
projection reconstruction; undersampling artifacts; magnetic resonance imaging; PSF; k-space;
D O I
10.1002/jmri.20248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reduce undersampling artifacts for a given number of repetitions of the projection reconstruction (PR) sequence by modifying its k-space trajectory to sample more mid-frequencies while reducing the sampling coverage of the peripheral spatial frequencies. Materials and Methods: The single k-space spoke measured per repetition in the standard PR was modified so that one complete and two partial spokes were measured per repetition but with decreased k-space extent. The point spread functions (PSFs) and undersampling artifacts of the modified PR were compared with those of the standard PR for various numbers of projections. Phantom and in vivo images were used to assess the relative performance. Results: PSF analysis indicated that the modified PR method provided reduced undersampling artifacts with somewhat reduced spatial resolution. The phantom and in vivo images corroborated this. Conclusion: The modified PR trajectory provides reduced undersampling artifact vs. the standard PR. particularly when the number of projections is limited and the artifact level is high.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [1] Projection reconstruction MR imaging for the reduction of artifacts caused by interview motion
    Univ of Ghent, Ghent, Belgium
    IEEE Nucl Sci Symp Med Imaging Conf, (1866-1867):
  • [2] Projection reconstruction MR imaging for the reduction of artifacts caused by interview motion
    Van de Walle, R
    Lemahieu, I
    Lateur, G
    Raskin, G
    Lemmerling, M
    Achten, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2253 - 2258
  • [3] Reduction of rigid-motion artifacts in interleaved projection reconstruction magnetic resonance imaging
    Van de Walle, R
    Lemahieu, I
    Raskin, G
    Lateur, G
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 648 - 651
  • [4] Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography
    Michalek, Jan
    MICROSCOPY AND MICROANALYSIS, 2015, 21 (06) : 1602 - 1615
  • [5] Characterizing radial undersampling artifacts for cardiac applications
    Peters, DC
    Rohatgi, P
    Botnar, RM
    Yeon, SB
    Kissinger, KV
    Manning, WJ
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) : 396 - 403
  • [6] MOIRE UNDERSAMPLING ARTIFACTS IN DIGITAL ULTRASOUND IMAGES
    OPHIR, J
    BRINCH, JM
    ULTRASONIC IMAGING, 1982, 4 (04) : 311 - 320
  • [7] Reduction of metal artifacts using subtracted CT projection data
    Tolakanahalli, R
    Medow, JE
    Hsieh, J
    Chen, GH
    Mistretta, CA
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 636 - 643
  • [8] Artifacts and sampling requirement in transmission CT reconstruction with truncated projection data
    Gregoriou, GK
    Tsui, BMW
    Frey, EC
    Lalush, DS
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1336 - 1340
  • [9] A modified algebraic reconstruction algorithm for sparse projection
    Li, Hongyan
    Wan, Zhonglin
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (18)
  • [10] Centering the projection reconstruction trajectory: Reducing gradient delay errors
    Peters, DC
    Derbyshire, JA
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 1 - 6