Partial ceramic crowns:: Influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro

被引:53
|
作者
Federlin, M. [1 ]
Krifka, S. [1 ]
Herpich, M. [1 ]
Hiller, K-A [1 ]
Schmalz, G. [1 ]
机构
[1] Univ Regensburg, Sch Dent, Dept Operat Dent & Periodontol, D-8400 Regensburg, Germany
关键词
D O I
10.2341/06-70
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study tested the effects of two different ceramic thicknesses, two preparation designs and two different luting agents on the marginal integrity and fracture resistance of partial ceramic crowns (PCC). Eighty extracted human molars were prepared according to the following preparation designs: a) Coverage of functional cusps/butt joint (n=40), b) Horizontal reduction of functional cusps (n=40). PCC (Vita Mark II, Cerec3 System) were fabricated and the ceramic thickness of the functional cusps was adjusted to 1): 0.5-1.0 mm and 2):1.5-2.0 mm. PCC were adhesively luted to the cavities with either Excite/VariolinkII (VL) or RelyX Unicem. (RX). The specimens were exposed to thermocycling and central mechanical loading (5000 x 5 degrees C-55 degrees C; 30 second/cycle; 50,0000 x 72.5N, 1.6Hz). Marginal integrity was assessed by evaluating dye penetration (fuchsine) on multiple sections in the bucco-oral direction by relating the actual penetration distance to the maximal length of the corresponding cavity wall (100%). Restoration/luting agent (RL)- and tooth/luting agent (TL) interfaces were evaluated separately. The data were statistically analyzed with the Mann Whitney U-test and the Error Rates Method (ERM), and the fracture rates were analyzed with the XI-test. Dye penetration data indicated that ceramic thickness and luting agent had a statistically significant influence upon marginal integrity in general, irrespective of all other parameters (ERM): RX showed significantly lower microleakage along the RL interface than VL. VL revealed significantly lower microleakage at the TL interface than RX. Fifteen PCC of group 1 (0.5-1.0 mm.) and two PCC of group 2 (1.5-2.0 mm) were fractured after thermocycling and central mechanical loading, with the difference being statistically significant. PCC fabricated from industrially sintered feldspathic ceramic should have at least a thickness of 1.5-2.0 mm in stress-bearing areas.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 50 条
  • [41] INFLUENCE OF THE TOTAL OCCLUSAL CONVERGENCE OF COMPOSITE CORES ON THE FRACTURE RESISTANCE OF OVERLAYING CERAMIC CROWNS
    Abdelaziz, Khalid M.
    Khalil, Ashraf A.
    Alabusaber, Abdullah Musri
    Alqhtani, Ayed Saeed
    INTERNATIONAL JOURNAL OF MEDICAL DENTISTRY, 2022, 26 (01) : 90 - 96
  • [42] Influence of Thermomechanical Fatigue Loading on the Fracture Resistance of All-ceramic Posterior Crowns
    Senyilmaz, Dilek Pinar
    Canay, Senay
    Heydecke, Guido
    Strub, Joerg Rudolf
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2010, 18 (02): : 50 - 54
  • [43] Influence of Proximal-Cervical Undermined Enamel Areas on Marginal Quality and Enamel Integrity of Laboratory and CAD/CAM Ceramic Inlays and Partial Crowns
    Frankenberger, Roland
    Friedrich, Katharina
    Dudek, Marie-Christine
    Winter, Julia
    Kraemer, Norbert
    Roggendorf, Matthias J.
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2025, 16 (03)
  • [44] Influence of surface treatment on the in-vitro fracture resistance of zirconia-based all-ceramic anterior crowns
    Schmitter, M.
    Lotze, G.
    Boemicke, W.
    Rues, S.
    DENTAL MATERIALS, 2015, 31 (12) : 1552 - 1560
  • [45] Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study
    Lin, Jie
    Cai, Pingping
    Zhuo, Yingying
    Lin, Ling
    Zheng, Zhiqiang
    BMC ORAL HEALTH, 2023, 23 (01)
  • [46] Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study
    Jie Lin
    Pingping Cai
    Yingying Zhuo
    Ling Lin
    Zhiqiang Zheng
    BMC Oral Health, 23
  • [47] Fracture Resistance of a Selection of Full-Contour All-Ceramic Crowns: An In Vitro Study
    Zesewitz, Tim F.
    Knauber, Andreas W.
    Nothdurft, Frank P.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (03) : 264 - 266
  • [48] Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations
    Soares, CJ
    Martins, LRM
    Fonseca, RB
    Correr-Sobrinho, L
    Fernandes, AJ
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (06): : 421 - 429
  • [49] CAD/CAM lithium disilicate ceramic crowns: Effect of occlusal thickness on fracture resistance and fractographic analysis
    Jurado, Carlos A.
    Pinedo, Francisco
    Cortes Trevino, Daniel Alberto
    Williams, Quotasze
    Marquez-Conde, Alberto
    Irie, Masao
    Tsujimoto, Akimasa
    DENTAL MATERIALS JOURNAL, 2022, 41 (05) : 705 - 709
  • [50] Dynamic fatigue and fracture resistance of non-retentive all-ceramic full-coverage molar restorations. Influence of ceramic material and preparation design
    Clausen, Jan-Ole
    Abou Tara, Milia
    Kern, Matthias
    DENTAL MATERIALS, 2010, 26 (06) : 533 - 538