Partial ceramic crowns:: Influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro

被引:53
|
作者
Federlin, M. [1 ]
Krifka, S. [1 ]
Herpich, M. [1 ]
Hiller, K-A [1 ]
Schmalz, G. [1 ]
机构
[1] Univ Regensburg, Sch Dent, Dept Operat Dent & Periodontol, D-8400 Regensburg, Germany
关键词
D O I
10.2341/06-70
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study tested the effects of two different ceramic thicknesses, two preparation designs and two different luting agents on the marginal integrity and fracture resistance of partial ceramic crowns (PCC). Eighty extracted human molars were prepared according to the following preparation designs: a) Coverage of functional cusps/butt joint (n=40), b) Horizontal reduction of functional cusps (n=40). PCC (Vita Mark II, Cerec3 System) were fabricated and the ceramic thickness of the functional cusps was adjusted to 1): 0.5-1.0 mm and 2):1.5-2.0 mm. PCC were adhesively luted to the cavities with either Excite/VariolinkII (VL) or RelyX Unicem. (RX). The specimens were exposed to thermocycling and central mechanical loading (5000 x 5 degrees C-55 degrees C; 30 second/cycle; 50,0000 x 72.5N, 1.6Hz). Marginal integrity was assessed by evaluating dye penetration (fuchsine) on multiple sections in the bucco-oral direction by relating the actual penetration distance to the maximal length of the corresponding cavity wall (100%). Restoration/luting agent (RL)- and tooth/luting agent (TL) interfaces were evaluated separately. The data were statistically analyzed with the Mann Whitney U-test and the Error Rates Method (ERM), and the fracture rates were analyzed with the XI-test. Dye penetration data indicated that ceramic thickness and luting agent had a statistically significant influence upon marginal integrity in general, irrespective of all other parameters (ERM): RX showed significantly lower microleakage along the RL interface than VL. VL revealed significantly lower microleakage at the TL interface than RX. Fifteen PCC of group 1 (0.5-1.0 mm.) and two PCC of group 2 (1.5-2.0 mm) were fractured after thermocycling and central mechanical loading, with the difference being statistically significant. PCC fabricated from industrially sintered feldspathic ceramic should have at least a thickness of 1.5-2.0 mm in stress-bearing areas.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 50 条
  • [21] The effect of two preparation designs on the fracture resistance and marginal adaptation of two types of ceramic crowns using CAD/CAM technology (In vitro study)
    Ashour, Akram Moamen
    El-Kateb, Mohamed Mahmoud
    Azer, Amir Shoukry
    BMC ORAL HEALTH, 2024, 24 (01):
  • [22] The influence of different cements on the fracture resistance and marginal adaptation of all-ceramic and fiber-reinforced crowns
    Behr, M
    Rosentritt, M
    Mangelkramer, M
    Handel, G
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (05) : 538 - 542
  • [23] Influence of material thickness on fractural strength of CAD/CAM fabricated ceramic crowns
    Zimmermann, Moritz
    Egli, Gustav
    Zaruba, Markus
    Mehl, Albert
    DENTAL MATERIALS JOURNAL, 2017, 36 (06) : 778 - 783
  • [24] Influence of Bioactive, Resin and Glass Ionomer luting cements on the fracture loads of dentin bonded ceramic crowns
    Vohra, Fahim
    Altwaim, Manea
    Alshuwaier, Abdulaziz S.
    Al Deeb, Modhi
    Alfawaz, Yasser
    Alrabiah, Mohammed
    Abduljabbar, Tariq
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (03) : 416 - 421
  • [25] Fracture resistance of three different all-ceramic crowns: In vitro study
    Alarwali, Ammar M.
    Kutty, Muralithran G.
    Al-Haddad, Afaf Y.
    Gonzalez, Maria Angela G.
    AMERICAN JOURNAL OF DENTISTRY, 2018, 31 (01): : 39 - 44
  • [26] Influence of Different Zirconia Coping Designs on the Fracture Resistance of All-Ceramic Crowns: An In Vitro Study
    Shetty, Sanath K.
    Fayaz, Tharammal
    Zahid, Mohammed
    Suhaim, Karkala S.
    Ragher, Mallikarjun
    Hasan, Mohammed S.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 517 - 522
  • [27] Influence of cyclic loading and luting agents on the fracture strength of two all-ceramic crowns.
    Attia, A.
    Kern, M.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B45 - B45
  • [28] Influence of Root Post Materials and Aging on Fracture Strength and Marginal Gap Quality of Ceramic Crowns-An In Vitro Study
    Hennig, Christoph-Ludwig
    Stoecker, Andre
    Nitzsche, Ann
    Marquetand, Justus
    Jacobs, Collin
    Jahn, Florentine
    MATERIALS, 2023, 16 (11)
  • [29] The effect of alumina core thickness on the fracture resistance of All-Ceramic crowns.
    Abed, HM
    Razzoog, ME
    Lang, BR
    Yaman, P
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 394 - 394
  • [30] The effect of preparation designs on the marginal and internal gaps in Cerec3 partial ceramic crowns
    Seo, Deoggyu
    Yi, Youngah
    Roh, Byoungduck
    JOURNAL OF DENTISTRY, 2009, 37 (05) : 374 - 382