Partial ceramic crowns:: Influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro

被引:53
|
作者
Federlin, M. [1 ]
Krifka, S. [1 ]
Herpich, M. [1 ]
Hiller, K-A [1 ]
Schmalz, G. [1 ]
机构
[1] Univ Regensburg, Sch Dent, Dept Operat Dent & Periodontol, D-8400 Regensburg, Germany
关键词
D O I
10.2341/06-70
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study tested the effects of two different ceramic thicknesses, two preparation designs and two different luting agents on the marginal integrity and fracture resistance of partial ceramic crowns (PCC). Eighty extracted human molars were prepared according to the following preparation designs: a) Coverage of functional cusps/butt joint (n=40), b) Horizontal reduction of functional cusps (n=40). PCC (Vita Mark II, Cerec3 System) were fabricated and the ceramic thickness of the functional cusps was adjusted to 1): 0.5-1.0 mm and 2):1.5-2.0 mm. PCC were adhesively luted to the cavities with either Excite/VariolinkII (VL) or RelyX Unicem. (RX). The specimens were exposed to thermocycling and central mechanical loading (5000 x 5 degrees C-55 degrees C; 30 second/cycle; 50,0000 x 72.5N, 1.6Hz). Marginal integrity was assessed by evaluating dye penetration (fuchsine) on multiple sections in the bucco-oral direction by relating the actual penetration distance to the maximal length of the corresponding cavity wall (100%). Restoration/luting agent (RL)- and tooth/luting agent (TL) interfaces were evaluated separately. The data were statistically analyzed with the Mann Whitney U-test and the Error Rates Method (ERM), and the fracture rates were analyzed with the XI-test. Dye penetration data indicated that ceramic thickness and luting agent had a statistically significant influence upon marginal integrity in general, irrespective of all other parameters (ERM): RX showed significantly lower microleakage along the RL interface than VL. VL revealed significantly lower microleakage at the TL interface than RX. Fifteen PCC of group 1 (0.5-1.0 mm.) and two PCC of group 2 (1.5-2.0 mm) were fractured after thermocycling and central mechanical loading, with the difference being statistically significant. PCC fabricated from industrially sintered feldspathic ceramic should have at least a thickness of 1.5-2.0 mm in stress-bearing areas.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 50 条
  • [31] Marginal Fit of Metal-Ceramic Copings: Effect of Luting Cements and Tooth Preparation Design
    dos Santos Paes de Almeida, Juliana Gomes
    Guedes, Carlos Gramani
    Abi-Rached, Filipe de Oliveira
    Trindade, Flavia Zardo
    Fonseca, Renata Garcia
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01): : E265 - E270
  • [32] Influence of cementation modes on fracture resistance of glass-ceramic crowns.
    Groten, M
    Jofre, J
    Probster, L
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 442 - 442
  • [33] Fracture resistance of partial and complete coverage veneers and ceramic crowns for maxillary central incisors
    Jurado, Carlos A.
    Mekled, Salwa
    Abuhammoud, Salahaldeen
    Azpiazu-Flores, Francisco X.
    Vegh, Daniel
    Wang, Ting
    Morton, Dean
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 420e1 - 420e6
  • [34] Impact of Ceramic Material and Preparation Design on Marginal Fit of Endocrown Restorations
    Soliman, Mai
    Alzahrani, Ghadeer
    Alabdualataif, Foton
    Eldwakhly, Elzahraa
    Alsamady, Sahar
    Aldegheishem, Alhanoof
    Abdelhafeez, Manal M.
    MATERIALS, 2022, 15 (16)
  • [35] Influence of filler geometry and viscosity of composite luting materials on marginal adhesive gap width and occlusal surface height of all-ceramic partial crowns
    Soliman, Sebastian
    Casel, Carolin
    Krug, Ralf
    Krastl, Gabriel
    Hahn, Britta
    DENTAL MATERIALS, 2022, 38 (04) : 601 - 612
  • [36] Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns
    Shiratsuchi, H
    Komine, F
    Kakehashi, Y
    Matsumura, H
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03): : 237 - 242
  • [38] Influence of infrastructure design and ceramic coverage material on stress development in posterior crowns
    Beck, Haine
    Basting, Roberta Tarkany
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (02): : 99 - 104
  • [39] THE INFLUENCE OF VENEERING PORCELAIN THICKNESS OF ALL-CERAMIC AND METAL CERAMIC CROWNS ON FAILURE RESISTANCE AFTER CYCLIC LOADING
    Shirakura, Akihiko
    Lee, Heeje
    Geminiani, Alessandro
    Ercoli, Carlo
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (02): : 119 - 127
  • [40] The in vitro failure of all-ceramic crowns and the connector area of fixed partial dentures using bilayered ceramic specimens: The influence of core to dentin thickness ratio
    Fleming, Garry J. P.
    Dickens, Michelle
    Thomas, Laura J.
    Harris, Jonathan J.
    DENTAL MATERIALS, 2006, 22 (08) : 771 - 777