Partial ceramic crowns:: Influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro

被引:53
|
作者
Federlin, M. [1 ]
Krifka, S. [1 ]
Herpich, M. [1 ]
Hiller, K-A [1 ]
Schmalz, G. [1 ]
机构
[1] Univ Regensburg, Sch Dent, Dept Operat Dent & Periodontol, D-8400 Regensburg, Germany
关键词
D O I
10.2341/06-70
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study tested the effects of two different ceramic thicknesses, two preparation designs and two different luting agents on the marginal integrity and fracture resistance of partial ceramic crowns (PCC). Eighty extracted human molars were prepared according to the following preparation designs: a) Coverage of functional cusps/butt joint (n=40), b) Horizontal reduction of functional cusps (n=40). PCC (Vita Mark II, Cerec3 System) were fabricated and the ceramic thickness of the functional cusps was adjusted to 1): 0.5-1.0 mm and 2):1.5-2.0 mm. PCC were adhesively luted to the cavities with either Excite/VariolinkII (VL) or RelyX Unicem. (RX). The specimens were exposed to thermocycling and central mechanical loading (5000 x 5 degrees C-55 degrees C; 30 second/cycle; 50,0000 x 72.5N, 1.6Hz). Marginal integrity was assessed by evaluating dye penetration (fuchsine) on multiple sections in the bucco-oral direction by relating the actual penetration distance to the maximal length of the corresponding cavity wall (100%). Restoration/luting agent (RL)- and tooth/luting agent (TL) interfaces were evaluated separately. The data were statistically analyzed with the Mann Whitney U-test and the Error Rates Method (ERM), and the fracture rates were analyzed with the XI-test. Dye penetration data indicated that ceramic thickness and luting agent had a statistically significant influence upon marginal integrity in general, irrespective of all other parameters (ERM): RX showed significantly lower microleakage along the RL interface than VL. VL revealed significantly lower microleakage at the TL interface than RX. Fifteen PCC of group 1 (0.5-1.0 mm.) and two PCC of group 2 (1.5-2.0 mm) were fractured after thermocycling and central mechanical loading, with the difference being statistically significant. PCC fabricated from industrially sintered feldspathic ceramic should have at least a thickness of 1.5-2.0 mm in stress-bearing areas.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 50 条
  • [1] Partial ceramic crowns: Influence of preparation design and luting material on internal adaptation
    Federlin, M
    Schmidt, S
    Hiller, KA
    Thonemann, B
    Schmalz, G
    OPERATIVE DENTISTRY, 2004, 29 (05) : 560 - 570
  • [2] Partial ceramic crowns. Influence of preparation design and luting material on margin integrity - scanning electron microscopic study
    Federlin, M
    Sipos, C
    Hiller, KA
    Thonemann, B
    Schmalz, G
    CLINICAL ORAL INVESTIGATIONS, 2005, 9 (01) : 8 - 17
  • [3] Partial ceramic crowns. Influence of preparation design and luting material on margin integrity—a scanning electron microscopic study
    Marianne Federlin
    C. Sipos
    K.-A. Hiller
    B. Thonemann
    G. Schmalz
    Clinical Oral Investigations, 2005, 9 : 8 - 17
  • [4] Ceramic Inlays and Partial Ceramic Crowns: Influence of Remaining Cusp Wall Thickness on the Marginal Integrity and Enamel Crack Formation In Vitro
    Krifka, S.
    Anthofer, T.
    Fritzsch, M.
    Hiller, K-A
    Schmalz, G.
    Federlin, M.
    OPERATIVE DENTISTRY, 2009, 34 (01) : 32 - 42
  • [5] Ceramic laminate veneers: effect of preparation design and ceramic thickness on fracture resistance and marginal quality in vitro
    Uwe Blunck
    Sabine Fischer
    Jan Hajtó
    Stefan Frei
    Roland Frankenberger
    Clinical Oral Investigations, 2020, 24 : 2745 - 2754
  • [6] Ceramic laminate veneers: effect of preparation design and ceramic thickness on fracture resistance and marginal quality in vitro
    Blunck, Uwe
    Fischer, Sabine
    Hajto, Jan
    Frei, Stefan
    Frankenberger, Roland
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (08) : 2745 - 2754
  • [7] Marginal integrity of partial ceramic crowns within dentin with different luting techniques and materials
    Schenke, F.
    Hiller, K-A
    Schmalz, G.
    Federlin, M.
    OPERATIVE DENTISTRY, 2008, 33 (05) : 516 - 525
  • [8] Partial ceramic crowns (Cerec 3): Marginal integrity in vitro.
    Federlin, M
    Schmidt, S
    Hiller, KA
    Schmalz, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A422 - A422
  • [9] Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation
    Kim, Jae-Hoon
    Cho, Byeong-Hoon
    Lee, Jin-Hee
    Kwon, Soo-Jung
    Yi, Young-Ah
    Shin, Yooseok
    Roh, Byoung-Duck
    Seo, Deog-Gyu
    ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (02) : 107 - 113
  • [10] Influence of Ceramic Thickness and Ceramic Materials on Fracture Resistance of Posterior Partial Coverage Restorations
    Bakeman, E. M.
    Rego, N.
    Chaiyabutr, Y.
    Kois, J. C.
    OPERATIVE DENTISTRY, 2015, 40 (02) : 211 - 217