Zero-Heat-Flux Thermometry for Non-Invasive Measurement of Core Body Temperature in Pigs

被引:15
|
作者
Guschlbauer, Maria [1 ]
Maul, Alexandra C. [1 ]
Yan, Xiaowei [2 ]
Herff, Holger [2 ]
Annecke, Thorsten [2 ]
Sterner-Kock, Anja [1 ]
Boettiger, Bernd W. [2 ]
Schroeder, Daniel C.
机构
[1] Univ Hosp Cologne, Ctr Med Expt, Cologne, Germany
[2] Univ Hosp Cologne, Dept Anaesthesiol & Intens Care Med, Cologne, Germany
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
MILD PERIOPERATIVE HYPOTHERMIA; THERAPEUTIC HYPOTHERMIA; HEMORRHAGIC-SHOCK; WOUND-INFECTION; CARDIAC-ARREST; BLOOD-LOSS; ANESTHESIA; SWINE; MODEL; NORMOTHERMIA;
D O I
10.1371/journal.pone.0150759
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Hypothermia is a severe, unpleasant side effect during general anesthesia. Thus, temperature surveillance is a prerequisite in general anesthesia settings during experimental surgeries. The gold standard to measure the core body temperature (T-core) is placement of a Swan-Ganz catheter in the pulmonary artery, which is a highly invasive procedure. Therefore, T-core is commonly examined in the urine bladder and rectum. However, these procedures are known for their inaccuracy and delayed record of temperatures. Zero-heat-flux (ZHF) thermometry is an alternative, non-invasive method quantifying T-core in human patients by applying a thermosensoric patch to the lateral forehead. Since the porcine cranial anatomy is different to the human's, the optimal location of the patch remains unclear to date. The aim was to compare three different patch locations of ZHF thermometry in a porcine hypothermia model. Hypothermia (33.0 degrees C T-core) was conducted in 11 anesthetized female pigs (26-30kg). T-core was measured continuously by an invasive Swan-Ganz catheter in the pulmonary artery (T-pulm). A ZHF thermometry device was mounted on three different defined locations. The smallest average difference between T-pulm and T-ZHF during stable temperatures was 0.21 +/- 0.16 degrees C at location A, where the patch was placed directly behind the eye. Also during rapidly changing temperatures location A showed the smallest bias with 0.48 +/- 0.29 degrees C. Location A provided the most reliable data for T-core. Therefore, the ZHF thermometry patch should be placed directly behind the left temporal corner of the eye to provide a non-invasive method for accurate measurement of T-core in pigs.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
    Dragan Brajkovic
    Michel B. Ducharme
    European Journal of Applied Physiology, 2005, 94 : 386 - 391
  • [42] Sustained exercise load by young adult females while wearing surgical mask raises core body temperature measured with zero-heat-flux thermometer
    Fukushima, Ayako
    Manabe, Yoshie
    Kosaka, Yuri
    Akagi, Shuji
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2023, 67 (08) : 1345 - 1352
  • [43] Unobtrusive Monitoring of Neonatal Brain Temperature Using a Zero-Heat-Flux Sensor Matrix
    Atallah, Louis
    Bongers, Edwin
    Lamichhane, Bishal
    Bambang-Oetomo, Sidarto
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (01) : 100 - 107
  • [44] AGREEMENT OF A ZERO-HEAT-FLUX CORE TEMPERATURE SYSTEM WITH MEASUREMENTS OBTAINED FROM NASAL AND ORAL TEMPERATURE PROBES DURING GENERAL ANESTHESIA
    West, Nicholas
    Cooke, Erin
    Merchant, Richard N.
    Gorges, Matthias
    ANESTHESIA AND ANALGESIA, 2018, 126 (04): : 722 - 722
  • [45] A non-invasive pipeline heat flux measurement method and application based on CFBG
    Cai, Qihui
    Liu, Mingyao
    Song, Han
    Li, Cong
    Ren, Yunhao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 235
  • [46] An Optimized Non-Invasive Blood Glucose and Temperature Body Measurement System
    Ibrahim, Hagar
    Darweesh, M. Saeed
    Soltan, Ahmed
    2022 11TH INTERNATIONAL CONFERENCE ON MODERN CIRCUITS AND SYSTEMS TECHNOLOGIES (MOCAST), 2022,
  • [47] Non-Invasive Temperature Measurement in the CPI
    Sosale, Guruprasad
    Chemical Engineering (United States), 2023, 130 (01): : 31 - 34
  • [48] Estimating Core Temperature during Exercise in Heat Using Non-Invasive Measurements
    Xu, Xiaojiang
    Karis, Anthony J.
    Mullen, Stephen P.
    Patel, Tejash
    Buller, Mark J.
    Santee, William R.
    FASEB JOURNAL, 2012, 26
  • [49] Non-invasive Body Temperature Measurement of Wild Chimpanzees Using Fecal Temperature Decline
    Jensen, Siv Aina
    Mundry, Roger
    Nunn, Charles L.
    Boesch, Christophe
    Leendertz, Fabian H.
    JOURNAL OF WILDLIFE DISEASES, 2009, 45 (02) : 542 - 546
  • [50] Non-invasive sensors for monitoring the body temperature and heart rate of pigs during transport
    Chesmore, ED
    Yoon, CS
    Talling, JC
    Van Driel, KS
    Lake, M
    PRECISION LIVESTOCK FARMING, 2003, : 33 - 37