Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement

被引:0
|
作者
Dragan Brajkovic
Michel B. Ducharme
机构
[1] Human Protection and Performance Group,Defence Research and Development Canada
[2] University of Ottawa, Toronto
来源
关键词
Deep tissue temperature; Thigh temperature; Core temperature;
D O I
暂无
中图分类号
学科分类号
摘要
This study evaluated a zero-heat-flow (ZHF), non-invasive temperature probe for in- vivo measurement of resting muscle temperature for up to 2 cm below the skin surface. The ZHF probe works by preventing heat loss from the tissue below the probe by actively heating the tissue until no temperature gradient exists across the probe. The skin temperature under the probe is then used as an indicator of the muscle temperature below. Eight subjects sat for 130 min during exposure to 28°C air. Vastus lateralis (lateral thigh) muscle temperature was measured non-invasively using a ZHF probe which covered an invasive multicouple probe (which measured tissue temperature 0.5 cm, 1 cm, 1.5 cm, and 2 cm below the skin) located 15 cm superior to the patella (T covered). T covered was evaluated against an uncovered control multicouple probe located 20 cm superior to the patella (T uncovered). Rectal temperature and lateral thigh skin temperature were also measured. Mean T uncovered (based on average temperatures at the 0.5 cm, 1 cm, 1.5 cm, and 2 cm depths) and Mean T covered were similar from time 0 min to 60 min. However, when the ZHF was turned on at 70 min, Mean T covered increased by 2.11±0.20°C by 130 min, while T uncovered remained stable. The ZHF probe temperature was similar to T covered at 1 cm and after time 85 min, significantly higher than T covered at the 0.5 cm, 1.5 cm, and 2 cm depths; however from a physiological standpoint, the temperatures between the different depths and the ZHF probe could be considered uniform (≤0.2°C separation). Rectal and thigh skin temperatures were stable at 36.99±0.08°C and 32.82±0.23°C, respectively. In conclusion, the non-invasive ZHF probe temperature was similar to the T covered temperatures directly measured up to 2 cm beneath the surface of the thigh, but all T covered temperatures were not representative of the true muscle temperature up to 2 cm below the skin because the ZHF probe heated the muscle by 2.11±0.20°C during its operation.
引用
收藏
页码:386 / 391
页数:5
相关论文
共 50 条
  • [1] Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
    Brajkovic, D
    Ducharme, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2005, 94 (04) : 386 - 391
  • [2] Deep temperature monitoring using a zero-heat-flow method
    Michiaki Yamakage
    Akiyoshi Namiki
    Journal of Anesthesia, 2003, 17 (2) : 108 - 115
  • [3] Non-invasive continuous core temperature measurement by zero heat flux
    Teunissen, L. P. J.
    Klewer, J.
    de Haan, A.
    de Koning, J. J.
    Daanen, H. A. M.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (05) : 559 - 570
  • [4] ZERO-HEAT-FLOW TRANSDUCER FOR MONITORING PERFUSION BLOOD TEMPERATURE
    TAMURA, T
    NEMOTO, T
    TOGAWA, T
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (11) : 644 - 646
  • [5] Non-invasive glucose measurement by use of metabolic heat conformation method
    Tang, Fei
    Wang, Xiaohao
    Wang, Dongsheng
    Li, Junfeng
    SENSORS, 2008, 8 (05) : 3335 - 3344
  • [6] Zero-Heat-Flux Thermometry for Non-Invasive Measurement of Core Body Temperature in Pigs
    Guschlbauer, Maria
    Maul, Alexandra C.
    Yan, Xiaowei
    Herff, Holger
    Annecke, Thorsten
    Sterner-Kock, Anja
    Boettiger, Bernd W.
    Schroeder, Daniel C.
    PLOS ONE, 2016, 11 (03):
  • [7] A new simple non-invasive method for flow measurement
    Zhu, HL
    Min, Z
    MEASUREMENT & CONTROL, 1999, 32 (06): : 178 - 180
  • [8] A NON-INVASIVE METHOD FOR THE MEASUREMENT OF SKIN BLOOD-FLOW
    LARSSON, H
    HELLSTROM, LG
    LINNARSSON, D
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (02) : N15 - N15
  • [9] A METHOD OF NON-INVASIVE QUANTITATIVE BLOOD-FLOW MEASUREMENT
    FISH, PJ
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (645): : 827 - 827
  • [10] Non-Invasive Temperature Measurement in the CPI
    Sosale, Guruprasad
    Chemical Engineering (United States), 2023, 130 (01): : 31 - 34