Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement

被引:0
|
作者
Dragan Brajkovic
Michel B. Ducharme
机构
[1] Human Protection and Performance Group,Defence Research and Development Canada
[2] University of Ottawa, Toronto
来源
关键词
Deep tissue temperature; Thigh temperature; Core temperature;
D O I
暂无
中图分类号
学科分类号
摘要
This study evaluated a zero-heat-flow (ZHF), non-invasive temperature probe for in- vivo measurement of resting muscle temperature for up to 2 cm below the skin surface. The ZHF probe works by preventing heat loss from the tissue below the probe by actively heating the tissue until no temperature gradient exists across the probe. The skin temperature under the probe is then used as an indicator of the muscle temperature below. Eight subjects sat for 130 min during exposure to 28°C air. Vastus lateralis (lateral thigh) muscle temperature was measured non-invasively using a ZHF probe which covered an invasive multicouple probe (which measured tissue temperature 0.5 cm, 1 cm, 1.5 cm, and 2 cm below the skin) located 15 cm superior to the patella (T covered). T covered was evaluated against an uncovered control multicouple probe located 20 cm superior to the patella (T uncovered). Rectal temperature and lateral thigh skin temperature were also measured. Mean T uncovered (based on average temperatures at the 0.5 cm, 1 cm, 1.5 cm, and 2 cm depths) and Mean T covered were similar from time 0 min to 60 min. However, when the ZHF was turned on at 70 min, Mean T covered increased by 2.11±0.20°C by 130 min, while T uncovered remained stable. The ZHF probe temperature was similar to T covered at 1 cm and after time 85 min, significantly higher than T covered at the 0.5 cm, 1.5 cm, and 2 cm depths; however from a physiological standpoint, the temperatures between the different depths and the ZHF probe could be considered uniform (≤0.2°C separation). Rectal and thigh skin temperatures were stable at 36.99±0.08°C and 32.82±0.23°C, respectively. In conclusion, the non-invasive ZHF probe temperature was similar to the T covered temperatures directly measured up to 2 cm beneath the surface of the thigh, but all T covered temperatures were not representative of the true muscle temperature up to 2 cm below the skin because the ZHF probe heated the muscle by 2.11±0.20°C during its operation.
引用
收藏
页码:386 / 391
页数:5
相关论文
共 50 条
  • [31] Non-invasive volumetric blood flow measurement in the orbit
    Nèmeth, J
    Harkányi, Z
    Humml, F
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (07) : 927 - 928
  • [32] REVIEW OF NON-INVASIVE MEASUREMENT OF BLOOD-FLOW
    ROBERTS, VC
    BIOMEDICAL ENGINEERING, 1974, 9 (08) : 332 - &
  • [33] Plasma deposited thermocouple for non-invasive temperature measurement
    Grassini, Sabrina
    Mombello, Domenico
    Neri, Alessandra
    Parvis, Marco
    Vallan, Alberto
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 708 - +
  • [34] Temperature influence on non-invasive blood glucose measurement
    Zhang, Xiqin
    Yeo, Joon Hock
    OPTICAL DIAGNOSTICS AND SENSING IX, 2009, 7186
  • [35] QUANTITATIVE-DETERMINATION OF MUSCLE BLOOD-FLOW - A NEW NON-INVASIVE METHOD
    WEBER, F
    ANLAUF, M
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1988, 10 (04) : 726 - 726
  • [36] A NON-INVASIVE METHOD FOR MEASUREMENT OF CEREBRAL BLOOD-FLOW IN SPONTANEOUS MENINGEAL HEMORRHAGE
    TREMOULET, M
    GERAUD, G
    GUELL, A
    BES, A
    NEUROCHIRURGIE, 1983, 29 (04) : 235 - 240
  • [37] THE USE OF NON-INVASIVE HAEMOGLOBIN IN THE MEASUREMENT OF DIFFUSION CAPACITY
    Tekstra-Kay, C.
    Schoeffel, R. E.
    Bolton, D.
    Htun, C.
    King, G. G.
    RESPIROLOGY, 2012, 17 : 6 - 6
  • [38] A Non-Invasive Measurement Method of Pipeline Flow Rate Based on Dual FBG Sensors
    Li, Cong
    Liu, Ming-Yao
    Song, Han
    Yang, Xue-Li
    Wu, Yi-Hang
    IEEE SENSORS JOURNAL, 2022, 22 (06) : 5669 - 5677
  • [39] Non-invasive mapping of fluid temperature and flow in microsystems
    Cyca, MJ
    Spiewak, SA
    Hugo, RJ
    2005 International Conference on MEMS, NANO and Smart Systems, Proceedings, 2005, : 21 - 26
  • [40] Non-invasive hemoglobin measurement using optical method
    Ranjith, R.
    Priya, S.
    Dharshini, A. S. Kaviya
    Jeeva, J. B.
    HELIYON, 2024, 10 (15)