Zero-Heat-Flux Thermometry for Non-Invasive Measurement of Core Body Temperature in Pigs

被引:15
|
作者
Guschlbauer, Maria [1 ]
Maul, Alexandra C. [1 ]
Yan, Xiaowei [2 ]
Herff, Holger [2 ]
Annecke, Thorsten [2 ]
Sterner-Kock, Anja [1 ]
Boettiger, Bernd W. [2 ]
Schroeder, Daniel C.
机构
[1] Univ Hosp Cologne, Ctr Med Expt, Cologne, Germany
[2] Univ Hosp Cologne, Dept Anaesthesiol & Intens Care Med, Cologne, Germany
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
MILD PERIOPERATIVE HYPOTHERMIA; THERAPEUTIC HYPOTHERMIA; HEMORRHAGIC-SHOCK; WOUND-INFECTION; CARDIAC-ARREST; BLOOD-LOSS; ANESTHESIA; SWINE; MODEL; NORMOTHERMIA;
D O I
10.1371/journal.pone.0150759
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Hypothermia is a severe, unpleasant side effect during general anesthesia. Thus, temperature surveillance is a prerequisite in general anesthesia settings during experimental surgeries. The gold standard to measure the core body temperature (T-core) is placement of a Swan-Ganz catheter in the pulmonary artery, which is a highly invasive procedure. Therefore, T-core is commonly examined in the urine bladder and rectum. However, these procedures are known for their inaccuracy and delayed record of temperatures. Zero-heat-flux (ZHF) thermometry is an alternative, non-invasive method quantifying T-core in human patients by applying a thermosensoric patch to the lateral forehead. Since the porcine cranial anatomy is different to the human's, the optimal location of the patch remains unclear to date. The aim was to compare three different patch locations of ZHF thermometry in a porcine hypothermia model. Hypothermia (33.0 degrees C T-core) was conducted in 11 anesthetized female pigs (26-30kg). T-core was measured continuously by an invasive Swan-Ganz catheter in the pulmonary artery (T-pulm). A ZHF thermometry device was mounted on three different defined locations. The smallest average difference between T-pulm and T-ZHF during stable temperatures was 0.21 +/- 0.16 degrees C at location A, where the patch was placed directly behind the eye. Also during rapidly changing temperatures location A showed the smallest bias with 0.48 +/- 0.29 degrees C. Location A provided the most reliable data for T-core. Therefore, the ZHF thermometry patch should be placed directly behind the left temporal corner of the eye to provide a non-invasive method for accurate measurement of T-core in pigs.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Prediction of human core body temperature using non-invasive measurement methods
    Reto Niedermann
    Eva Wyss
    Simon Annaheim
    Agnes Psikuta
    Sarah Davey
    René Michel Rossi
    International Journal of Biometeorology, 2014, 58 : 7 - 15
  • [22] Prediction of human core body temperature using non-invasive measurement methods
    Niedermann, Reto
    Wyss, Eva
    Annaheim, Simon
    Psikuta, Agnes
    Davey, Sarah
    Rossi, Rene Michel
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2014, 58 (01) : 7 - 15
  • [23] Forced-air warming and continuous core temperature monitoring with zero-heat-flux thermometry during cesarean section: a retrospective observational cohort study
    Marin, Laurentiu
    Hoecker, Jan
    Esser, Andre
    Terhorst, Rainer
    Sauerwald, Axel
    Schroeder, Stefan
    BRAZILIAN JOURNAL OF ANESTHESIOLOGY, 2022, 72 (04): : 484 - 492
  • [24] Measuring core body temperature with a non-invasive sensor
    Mazgaoker, Savyon
    Ketko, Itay
    Yanovich, Ran
    Heled, Yuval
    Epstein, Yoram
    JOURNAL OF THERMAL BIOLOGY, 2017, 66 : 17 - 20
  • [25] In response to: “Temperature monitoring with zero-heat-flux technology in neurosurgical patients”
    Eero Pesonen
    Marja Silvasti-Lundell
    Tomi T. Niemi
    Riku Kivisaari
    Juha Hernesniemi
    Marja-Tellervo Mäkinen
    Journal of Clinical Monitoring and Computing, 2019, 33 : 931 - 932
  • [26] Toward Non-Invasive Core Body Temperature Sensing
    Guido, Katrina
    Bringer, Alexandra
    Kiourti, Asimina
    2021 UNITED STATES NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2021, : 164 - 165
  • [27] Non-invasive, transient determination of the core temperature of a heat-generating solid body
    Dean Anthony
    Daipayan Sarkar
    Ankur Jain
    Scientific Reports, 6
  • [28] In response to: "Temperature monitoring with zero-heat-flux technology in neurosurgical patients"
    Pesonen, Eero
    Silvasti-Lundell, Marja
    Niemi, Tomi T.
    Kivisaari, Riku
    Hernesniemi, Juha
    Makinen, Marja-Tellervo
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (05) : 931 - 932
  • [29] Non-invasive, transient determination of the core temperature of a heat-generating solid body
    Anthony, Dean
    Sarkar, Daipayan
    Jain, Ankur
    SCIENTIFIC REPORTS, 2016, 6
  • [30] Feasibility analysis of applying non-invasive core body temperature measurement in sleep research
    Xu, Xinbo
    Wu, Gang
    Lian, Zhiwei
    Xu, Hongzhi
    ENERGY AND BUILDINGS, 2024, 303