Accuracy and Reliability of a Handheld, Nonmydriatic Fundus Camera for the Remote Detection of Optic Disc Edema

被引:19
|
作者
Bursztyn, Lulu [1 ]
Woodward, Maria A. [2 ]
Cornblath, Wayne T. [2 ]
Grabe, Hilary M. [3 ]
Trobe, Jonathan D. [2 ]
Niziol, Leslie [2 ]
De Lott, Lindsey B. [2 ]
机构
[1] Western Univ, Dept Ophthalmol, London, ON, Canada
[2] Univ Michigan, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[3] Univ Bern, Bern Univ Hosp, Inselspital, Dept Ophthalmol, Bern, Switzerland
关键词
ophthalmology; telemedicine; telehealth; emergency medicine; teletrauma; ACUTE-PHASE RETINOPATHY; DIABETIC-RETINOPATHY; MEDICAL-STUDENTS; EMERGENCY-DEPARTMENT; PHYSICAL-EXAMINATION; EXAMINATION SKILLS; DIGITAL IMAGE; TELEMEDICINE; PHOTOGRAPHY; OPHTHALMOSCOPY;
D O I
10.1089/tmj.2017.0120
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Optic disc edema can be an important indicator of serious neurological disease, but is poorly detected using the direct ophthalmoscope. Portable fundus photography may overcome this difficulty. Introduction: The purpose of this study was to determine the sensitivity and specificity of a handheld, nonmydriatic fundus camera for the detection of optic disc edema. Materials and Methods: Retrospective review of nonmydriatic optic disc photographs taken with a portable fundus camera (Pictor Plus; Volk Optical, Mentor, OH) from the University of Michigan Neuro-Ophthalmology Clinics. We included 103 consecutive eyes with optic disc edema and 103 consecutive eyes without optic disc edema of 109 patients. Four masked neuro-ophthalmologists graded a single photograph of each optic disc presented in randomized order and documented the presence of optic disc edema. Sensitivity and specificity of graders' photographic interpretation was compared with clinical examinations. Reliability of assessments within and between graders was determined using kappa statistics. Results: The sensitivity and specificity for detection of optic disc edema were 71.8-92.2% and 81.6-95.2%, respectively. Photos were found to be ungradable in 0-8.3% of cases. The intergrader reliabilities ranged from 0.60 [95% confidence interval (CI): 0.52-0.67] to 0.72 (95% CI: 0.66-0.77). Intragrader reliability ranged from 0.76 (95% CI: 0.63-0.92) to 0.82 (95% CI: 0.69-0.95). Discussion: Photographs taken with portable, nonmydriatic technology met threshold sensitivity and specificity for remote screening for optic disc edema when performed by most, but not all graders. Reliability between graders was moderate-strong and strong within individual providers. Conclusions: Portable photography holds promise for use in remote screening of optic disc edema.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [41] Optic Disc Region of Interest Localization in Fundus Image for Glaucoma Detection in ARGALI
    Zhang, Zhuo
    Lee, Beng Hai
    Liu, Jiang
    Wong, Damon Wing Kee
    Tan, Ngan Meng
    Lim, Joo Hwee
    Yin, Fengshou
    Huang, Weimin
    Li, Huiqi
    Wong, Tien Yin
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 3, 2010, : 534 - +
  • [42] Simultaneous Macula Detection and Optic Disc Boundary Segmentation in Retinal Fundus Images
    Girard, Fantin
    Kavalec, Conrad
    Grenier, Bastien
    Ben Tahar, Houssem
    Cheriet, Farida
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [43] Optic disc detection in color fundus images using ant colony optimization
    Pereira, Carla
    Goncalves, Luis
    Ferreira, Manuel
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (03) : 295 - 303
  • [44] Automatic Optic Disc Detection in Retinal Fundus Images Based on Geometric Features
    Figueiredo, Isabel N.
    Kumar, Sunil
    IMAGE ANALYSIS AND RECOGNITION, ICIAR 2014, PT II, 2014, 8815 : 285 - 292
  • [45] Optic disc detection and segmentation using saliency mask in retinal fundus images
    Zaaboub, Nihal
    Sandid, Faten
    Douik, Ali
    Solaiman, Basel
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 150
  • [46] Automated Detection of Optic Disc for the Analysis of Retina Using Color Fundus Image
    Zubair, Muhammad
    Yamin, Abubakar
    Khan, Shoab A.
    2013 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST 2013), 2013, : 239 - 242
  • [47] Accuracy of the smartphone-based nonmydriatic retinal camera in the detection of sight-threatening diabetic retinopathy
    Prathiba, Vijayaraghavan
    Rajalakshmi, Ramachandran
    Arulmalar, Subramaniam
    Usha, Manoharan
    Subhashini, Radhakrishnan
    Gilbert, Clare E.
    Anjana, Ranjit Mohan
    Mohan, Viswanathan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 : S42 - S46
  • [48] Optic disc recognition in images taken of premature infants using the RetCam 120™ digital fundus camera
    Toniappa, A
    Barman, SA
    Fielder, AR
    Moseley, MJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U286 - U286
  • [49] Reliability of optic disc edema area in estimating the severity of papilledema in patients with POEMS syndrome
    Liu, Ling-shan
    Zhang, Xiao
    Zhao, Hao
    Gao, Xue-min
    Zhou, Dao-bin
    Dai, Rong-ping
    Li, Jian
    ORPHANET JOURNAL OF RARE DISEASES, 2020, 15 (01)
  • [50] Reliability of optic disc edema area in estimating the severity of papilledema in patients with POEMS syndrome
    Ling-shan Liu
    Xiao Zhang
    Hao Zhao
    Xue-min Gao
    Dao-bin Zhou
    Rong-ping Dai
    Jian Li
    Orphanet Journal of Rare Diseases, 15