Accuracy and Reliability of a Handheld, Nonmydriatic Fundus Camera for the Remote Detection of Optic Disc Edema

被引:19
|
作者
Bursztyn, Lulu [1 ]
Woodward, Maria A. [2 ]
Cornblath, Wayne T. [2 ]
Grabe, Hilary M. [3 ]
Trobe, Jonathan D. [2 ]
Niziol, Leslie [2 ]
De Lott, Lindsey B. [2 ]
机构
[1] Western Univ, Dept Ophthalmol, London, ON, Canada
[2] Univ Michigan, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[3] Univ Bern, Bern Univ Hosp, Inselspital, Dept Ophthalmol, Bern, Switzerland
关键词
ophthalmology; telemedicine; telehealth; emergency medicine; teletrauma; ACUTE-PHASE RETINOPATHY; DIABETIC-RETINOPATHY; MEDICAL-STUDENTS; EMERGENCY-DEPARTMENT; PHYSICAL-EXAMINATION; EXAMINATION SKILLS; DIGITAL IMAGE; TELEMEDICINE; PHOTOGRAPHY; OPHTHALMOSCOPY;
D O I
10.1089/tmj.2017.0120
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Optic disc edema can be an important indicator of serious neurological disease, but is poorly detected using the direct ophthalmoscope. Portable fundus photography may overcome this difficulty. Introduction: The purpose of this study was to determine the sensitivity and specificity of a handheld, nonmydriatic fundus camera for the detection of optic disc edema. Materials and Methods: Retrospective review of nonmydriatic optic disc photographs taken with a portable fundus camera (Pictor Plus; Volk Optical, Mentor, OH) from the University of Michigan Neuro-Ophthalmology Clinics. We included 103 consecutive eyes with optic disc edema and 103 consecutive eyes without optic disc edema of 109 patients. Four masked neuro-ophthalmologists graded a single photograph of each optic disc presented in randomized order and documented the presence of optic disc edema. Sensitivity and specificity of graders' photographic interpretation was compared with clinical examinations. Reliability of assessments within and between graders was determined using kappa statistics. Results: The sensitivity and specificity for detection of optic disc edema were 71.8-92.2% and 81.6-95.2%, respectively. Photos were found to be ungradable in 0-8.3% of cases. The intergrader reliabilities ranged from 0.60 [95% confidence interval (CI): 0.52-0.67] to 0.72 (95% CI: 0.66-0.77). Intragrader reliability ranged from 0.76 (95% CI: 0.63-0.92) to 0.82 (95% CI: 0.69-0.95). Discussion: Photographs taken with portable, nonmydriatic technology met threshold sensitivity and specificity for remote screening for optic disc edema when performed by most, but not all graders. Reliability between graders was moderate-strong and strong within individual providers. Conclusions: Portable photography holds promise for use in remote screening of optic disc edema.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [21] Detection of the optic disc in fundus images by combining probability models
    Harangi, Balazs
    Hajdu, Andras
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 65 : 10 - 24
  • [22] Clinical validation of a smartphone-based handheld fundus camera for the evaluation of optic nerve head
    Titoneli, Carolina C.
    Filho, Marcio S.
    Lencione, Diego
    Vieira, Flavio Pascoal
    Stuchi, Jose Augusto
    Paula, Jayter S.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2021, 84 (06) : 531 - 537
  • [23] COMPARISON OF ACCURACY IN ARTIFICIAL BEE COLONY ALGORITHM AND BAT ALGORITHM FOR THE DETECTION OF OPTIC DISC IN RETINAL FUNDUS IMAGING
    Arun, S.
    Priya, M. Vishnu
    INTERNATIONAL JOURNAL OF EARLY CHILDHOOD SPECIAL EDUCATION, 2022, 14 (03) : 5676 - 5687
  • [24] Accuracy of Funduscopy to Identify True Edema versus Pseudoedema of the Optic Disc
    Carta, Arturo
    Favilla, Stefania
    Prato, Marco
    Bianchi-Marzoli, Stefania
    Sadun, Alfredo A.
    Mora, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 1 - 6
  • [25] ELLIPSE DETECTION OF OPTIC DISC-AND-CUP BOUNDARY IN FUNDUS IMAGES
    Wang, Zeya
    Dong, Nanqing
    Rosario, Sean D.
    Xu, Min
    Xie, Pengtao
    Xing, Eric P.
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 601 - 604
  • [26] Automatic Detection of Optic Disc and Fovea from Colour Fundus Images
    Elena Martinez-Perez, M.
    Elze, Tobias
    Rauscher, Franziska G.
    INTELLIGENT COMPUTING, VOL 1, 2024, 2024, 1016 : 383 - 395
  • [27] Automatic Tool for Optic Disc and Cup Detection on Retinal Fundus Images
    Angel Fernandez-Granero, Miguel
    Sarmiento Vega, Auxiliadora
    Isabel Garcia, Anabel
    Sanchez-Morillo, Daniel
    Jimenez, Soledad
    Alemany, Pedro
    Fondon, Irene
    ADVANCES IN COMPUTATIONAL INTELLIGENCE, IWANN 2017, PT I, 2017, 10305 : 246 - 256
  • [28] Perceptually Adapted Method for Optic Disc Detection on Retinal Fundus Images
    Fondon, Irene
    van Grinsven, Mark J. J. P.
    Sanchez, Clara I.
    Saez, Aurora
    2013 IEEE 26TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2013, : 279 - 284
  • [29] Combining algorithms for automatic detection of optic disc and macula in fundus images
    Qureshi, Rashid Jalal
    Kovacs, Laszlo
    Harangi, Balazs
    Nagy, Brigitta
    Peto, Tunde
    Hajdu, Andras
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2012, 116 (01) : 138 - 145
  • [30] Optic disc and macula detection in fundus images by means of template matching
    Garduno-Alvarado, Tzolkin
    Elena Martinez-Perez, M.
    Martinez-Castellanos, Maria A.
    Rodriguez-Quinones, Luvia
    Salinas-Longoria, Samantha M.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 134 - 137