Accuracy and Reliability of a Handheld, Nonmydriatic Fundus Camera for the Remote Detection of Optic Disc Edema

被引:19
|
作者
Bursztyn, Lulu [1 ]
Woodward, Maria A. [2 ]
Cornblath, Wayne T. [2 ]
Grabe, Hilary M. [3 ]
Trobe, Jonathan D. [2 ]
Niziol, Leslie [2 ]
De Lott, Lindsey B. [2 ]
机构
[1] Western Univ, Dept Ophthalmol, London, ON, Canada
[2] Univ Michigan, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[3] Univ Bern, Bern Univ Hosp, Inselspital, Dept Ophthalmol, Bern, Switzerland
关键词
ophthalmology; telemedicine; telehealth; emergency medicine; teletrauma; ACUTE-PHASE RETINOPATHY; DIABETIC-RETINOPATHY; MEDICAL-STUDENTS; EMERGENCY-DEPARTMENT; PHYSICAL-EXAMINATION; EXAMINATION SKILLS; DIGITAL IMAGE; TELEMEDICINE; PHOTOGRAPHY; OPHTHALMOSCOPY;
D O I
10.1089/tmj.2017.0120
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Optic disc edema can be an important indicator of serious neurological disease, but is poorly detected using the direct ophthalmoscope. Portable fundus photography may overcome this difficulty. Introduction: The purpose of this study was to determine the sensitivity and specificity of a handheld, nonmydriatic fundus camera for the detection of optic disc edema. Materials and Methods: Retrospective review of nonmydriatic optic disc photographs taken with a portable fundus camera (Pictor Plus; Volk Optical, Mentor, OH) from the University of Michigan Neuro-Ophthalmology Clinics. We included 103 consecutive eyes with optic disc edema and 103 consecutive eyes without optic disc edema of 109 patients. Four masked neuro-ophthalmologists graded a single photograph of each optic disc presented in randomized order and documented the presence of optic disc edema. Sensitivity and specificity of graders' photographic interpretation was compared with clinical examinations. Reliability of assessments within and between graders was determined using kappa statistics. Results: The sensitivity and specificity for detection of optic disc edema were 71.8-92.2% and 81.6-95.2%, respectively. Photos were found to be ungradable in 0-8.3% of cases. The intergrader reliabilities ranged from 0.60 [95% confidence interval (CI): 0.52-0.67] to 0.72 (95% CI: 0.66-0.77). Intragrader reliability ranged from 0.76 (95% CI: 0.63-0.92) to 0.82 (95% CI: 0.69-0.95). Discussion: Photographs taken with portable, nonmydriatic technology met threshold sensitivity and specificity for remote screening for optic disc edema when performed by most, but not all graders. Reliability between graders was moderate-strong and strong within individual providers. Conclusions: Portable photography holds promise for use in remote screening of optic disc edema.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [31] A pilot study on diabetes detection using handheld fundus camera and mobile app development
    Al-Absi, Hamada R. H.
    Muchori, Gilbert Njihia
    Musleh, Saleh
    Basit, Syed Abdullah
    Islam, Mohammad Tariqul
    Mou, Younss Ait
    Alam, Tanvir
    DISCOVER APPLIED SCIENCES, 2025, 7 (02)
  • [32] Comparison of 50° handheld fundus camera versus ultra-widefield table-top fundus camera for diabetic retinopathy detection and grading
    Edoardo Midena
    Luca Zennaro
    Cristian Lapo
    Tommaso Torresin
    Giulia Midena
    Luisa Frizziero
    Eye, 2023, 37 : 2994 - 2999
  • [33] Secondary glaucoma in uveitis: comparison of the optic nerve head morphology among a nonmydriatic fundus camera, HRT, and SD-OCT
    Pahlitzsch, Milena
    Klamann, Matthias K. J.
    Jacob, Saskia
    Erb, Carl
    Winterhalter, Sibylle
    Torun, Necip
    Maier, Anna-Karina B.
    Bertelmann, Eckart
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (03) : 299 - 305
  • [34] Comparison of 50° handheld fundus camera versus ultra-widefield table-top fundus camera for diabetic retinopathy detection and grading
    Midena, Edoardo
    Zennaro, Luca
    Lapo, Cristian
    Torresin, Tommaso
    Midena, Giulia
    Frizziero, Luisa
    EYE, 2023, 37 (14) : 2994 - 2999
  • [35] Determination of true optic disc area using a fundus camera technique: correlation with HRT measurements
    Quigley, MG
    Patel, VR
    Harasymowycz, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U113 - U113
  • [36] Automatic Detection and Elimination of an Optic Disc for Improving Drusen Detection Accuracy
    Prasath, Rama A.
    Ramya, M. M.
    2014 FIFTH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP 2014), 2014, : 117 - 121
  • [37] Automatic Optic Disc Detection in Digital Fundus Images Using Image Processing
    Akhade, Snehal B.
    Deshmukh, V. U.
    Deosarkar, S. B.
    2014 INTERNATIONAL CONFERENCE ON GREEN COMPUTING COMMUNICATION AND ELECTRICAL ENGINEERING (ICGCCEE), 2014,
  • [38] Detection of Optic Disc Abnormalities in Color Fundus Photographs Using Deep Learning
    Liu, T. Y. Alvin
    Wei, Jinchi
    Zhu, Hongxi
    Subramanian, Prem S.
    Myung, David
    Yi, Paul H.
    Hui, Ferdinand K.
    Unberath, Mathias
    Ting, Daniel S. W.
    Miller, Neil R.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2021, 41 (03) : 368 - 374
  • [39] Optic disc detection in color fundus images using ant colony optimization
    Carla Pereira
    Luís Gonçalves
    Manuel Ferreira
    Medical & Biological Engineering & Computing, 2013, 51 : 295 - 303
  • [40] Automated fovea and optic disc detection in the presence of occlusions in Fundus SLO Images
    Stadelmann, Marc
    Mosinska, Agata
    Gallardo, Mathias
    Sznitman, Raphael
    Munk, Marion
    Apostolopoulos, Stefanos
    Ciller, Carlos
    De Zanet, Sandro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)