Accuracy and Reliability of a Handheld, Nonmydriatic Fundus Camera for the Remote Detection of Optic Disc Edema

被引:19
|
作者
Bursztyn, Lulu [1 ]
Woodward, Maria A. [2 ]
Cornblath, Wayne T. [2 ]
Grabe, Hilary M. [3 ]
Trobe, Jonathan D. [2 ]
Niziol, Leslie [2 ]
De Lott, Lindsey B. [2 ]
机构
[1] Western Univ, Dept Ophthalmol, London, ON, Canada
[2] Univ Michigan, Dept Ophthalmol & Visual Sci, Ann Arbor, MI 48109 USA
[3] Univ Bern, Bern Univ Hosp, Inselspital, Dept Ophthalmol, Bern, Switzerland
关键词
ophthalmology; telemedicine; telehealth; emergency medicine; teletrauma; ACUTE-PHASE RETINOPATHY; DIABETIC-RETINOPATHY; MEDICAL-STUDENTS; EMERGENCY-DEPARTMENT; PHYSICAL-EXAMINATION; EXAMINATION SKILLS; DIGITAL IMAGE; TELEMEDICINE; PHOTOGRAPHY; OPHTHALMOSCOPY;
D O I
10.1089/tmj.2017.0120
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Optic disc edema can be an important indicator of serious neurological disease, but is poorly detected using the direct ophthalmoscope. Portable fundus photography may overcome this difficulty. Introduction: The purpose of this study was to determine the sensitivity and specificity of a handheld, nonmydriatic fundus camera for the detection of optic disc edema. Materials and Methods: Retrospective review of nonmydriatic optic disc photographs taken with a portable fundus camera (Pictor Plus; Volk Optical, Mentor, OH) from the University of Michigan Neuro-Ophthalmology Clinics. We included 103 consecutive eyes with optic disc edema and 103 consecutive eyes without optic disc edema of 109 patients. Four masked neuro-ophthalmologists graded a single photograph of each optic disc presented in randomized order and documented the presence of optic disc edema. Sensitivity and specificity of graders' photographic interpretation was compared with clinical examinations. Reliability of assessments within and between graders was determined using kappa statistics. Results: The sensitivity and specificity for detection of optic disc edema were 71.8-92.2% and 81.6-95.2%, respectively. Photos were found to be ungradable in 0-8.3% of cases. The intergrader reliabilities ranged from 0.60 [95% confidence interval (CI): 0.52-0.67] to 0.72 (95% CI: 0.66-0.77). Intragrader reliability ranged from 0.76 (95% CI: 0.63-0.92) to 0.82 (95% CI: 0.69-0.95). Discussion: Photographs taken with portable, nonmydriatic technology met threshold sensitivity and specificity for remote screening for optic disc edema when performed by most, but not all graders. Reliability between graders was moderate-strong and strong within individual providers. Conclusions: Portable photography holds promise for use in remote screening of optic disc edema.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 50 条
  • [1] Image quality and diagnostic accuracy of a handheld nonmydriatic fundus camera: Feasibility of a telemedical approach in screening retinal diseases
    Lin, Tai-Chi
    Chiang, Yueh-Hua
    Hsu, Chih-Lu
    Liao, Long-Sheng
    Chen, Yi-Ying
    Chen, Shih-Jen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2020, 83 (10) : 962 - 966
  • [2] Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients
    Munoz-Negrete, Francisco J.
    Contreras, Ines
    Oblanca, Noelia
    Dolores Pinazo-Duran, M.
    Rebolleda, Gema
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [3] Automated Detection of Optic Disc in Fundus Images
    Burman, R.
    Almazroa, A.
    Raahemifar, K.
    Lakshminarayanan, V.
    ADVANCES IN OPTICAL SCIENCE AND ENGINEERING, 2015, 166 : 327 - 334
  • [4] Predictors of Photographic Quality with a Handheld Nonmydriatic Fundus Camera Used for Screening of Vision-Threatening Diabetic Retinopathy
    Davila, Jose R.
    Sengupta, Sabyasachi S.
    Niziol, Leslie M.
    Sindal, Manavi D.
    Besirli, Cagri G.
    Upadhyaya, Swati
    Woodward, Maria A.
    Venkatesh, Rengaraj
    Robin, Alan L.
    Grubbs, Joseph, Jr.
    Newman-Casey, Paula Anne
    OPHTHALMOLOGICA, 2017, 238 (1-2) : 89 - 99
  • [5] Glaucoma Screening in Nepal: Cup-to-Disc Estimate With Standard Mydriatic Fundus Camera Compared to Portable Nonmydriatic Camera
    Miller, Sarah E.
    Thapa, Suman
    Robin, Alan L.
    Niziol, Leslie M.
    Ramulu, Pradeep Y.
    Woodward, Maria A.
    Paudyal, Indira
    Pitha, Ian
    Kim, Tyson N.
    Newman-Casey, Paula Anne
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 182 : 99 - 106
  • [6] Remote screening of retinal and optic disc diseases using handheld nonmydriatic cameras in programmed routine occupational health checkups onsite at work centers
    Zapata, Miguel A.
    Martin, Ruth
    Garcia-Arumi, Claudia
    Fonollosa, Alex
    Flores-Moreno, Ignacio
    Gallego-Pinazo, Roberto
    Gutierrez, Estanislao
    Abraldes, Maximino
    Zarranz-Ventura, Javier
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (03) : 575 - 583
  • [7] Remote screening of retinal and optic disc diseases using handheld nonmydriatic cameras in programmed routine occupational health checkups onsite at work centers
    Miguel A. Zapata
    Ruth Martín
    Claudia Garcia-Arumí
    Alex Fonollosa
    Ignacio Flores-Moreno
    Roberto Gallego-Pinazo
    Estanislao Gutiérrez
    Maximino Abraldes
    Javier Zarranz-Ventura
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 575 - 583
  • [8] Optic Disc Edema From Remote Uveal Melanoma
    Clark, Sireesha A.
    Lubow, Martin
    Ray-Chaudhury, Abhik
    Davidorf, Frederick H.
    Abdel-Rahman, Mohamed H.
    Cebulla, Colleen M.
    JAMA OPHTHALMOLOGY, 2013, 131 (01) : 115 - 117
  • [9] Remote Screening for Optic Nerve Cupping Using Smartphone-based Nonmydriatic Fundus Photography
    LaMonica, Lauren C.
    Bhardwaj, Mahesh K.
    Hawley, Nicola L.
    Naseri, Take
    Reupena, Muagatutia S.
    Cooper, Michael L.
    Cotran, Paul R.
    Roh, Shiyoung
    Ramsey, David J.
    JOURNAL OF GLAUCOMA, 2021, 30 (01) : 58 - 60
  • [10] Detection of age-related macular degeneration using a nonmydriatic digital camera and a standard film fundus camera
    Klein, R
    Meuer, SM
    Moss, SE
    Klein, BEK
    Neider, MW
    Reinke, J
    ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (11) : 1642 - 1646