摘要
In this paper we present a novel sample injection chip. Microvalves and microchannels are integrated on the chip. The valve is a passive lowpass valve that allows a liquid flow at a low flow rate and prohibits it when the flow rate exceeds a threshold. We can control the injection volume by changing the channel design. The chip consists of a channel substrate, an upper valve substrate and an under valve substrate. These substrates are separately fabricated and bonded by using MEMS techniques. The chip, not to leak at a pressure difference of 5.0MPa, was successfully applied to high performance liquid chromatography (HPLC). A specific volume of sample (100 nl) was injected to the HPLC column. The results show that the sample injection chip has the possibility of being used in the micro-HPLC systems.
引用
收藏
页码:979 / +
页数:2
相关论文
共 50 条
  • [41] Chiral separation of T3 enantiomers using stereoselective antibodies as a selector in micro-HPLC
    Koidl, Julia
    Hoedl, Heike
    Schmid, Martin G.
    Konrad, Marlene
    Petschauer, Sabine
    Kostner, Gerhard M.
    Guebitz, Gerald
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2006, 69 (1-2): : 33 - 42
  • [42] ESTIMATION OF RAT-BLOOD PLASMA-CORTICOSTERONE BY MEANS OF ADSORPTION MICRO-HPLC
    KHOKHA, AM
    VOPROSY MEDITSINSKOI KHIMII, 1989, 35 (05): : 122 - 127
  • [43] Study of Bed Homogenity of Methacrylate-Based Monolithic Columns for Micro-HPLC and CEC
    B. Buszewski
    M. Szumski
    Chromatographia, 2004, 60 : S261 - S267
  • [44] Study of bed homogenity of methacrylate-based monolithic columns for micro-HPLC and CEC
    Buszewski, B
    Szumski, M
    CHROMATOGRAPHIA, 2004, 60 (Suppl 1) : S261 - S267
  • [45] A world-to-chip microfluidic interconnection technology with dual functions of sample injection and sealing for a multichamber micro PCR chip
    Oh, KW
    Park, C
    Namkoong, K
    MEMS 2005 Miami: Technical Digest, 2005, : 714 - 717
  • [46] Chiral separation of natural and unnatural amino acid derivatives by micro-HPLC on a ristocetin a stationary phase
    Piccinini, AM
    Schmid, MG
    Pajpanova, T
    Pancheva, S
    Grueva, E
    Gübitz, G
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 61 (1-2): : 11 - 21
  • [47] ON THE QUANTITATIVE-DETERMINATION OF RARE DNA-BASES IN THE PG-RANGE BY MICRO-HPLC
    RANDT, C
    LINSCHEID, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (07): : 726 - 727
  • [48] HIGH-SPEED MICRO-HPLC FOR ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS IN ENVIRONMENTAL-SAMPLES
    JINNO, K
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (04): : 218 - 219
  • [49] DETERMINATION OF 5-FLUOROURACIL IN LIVER-TISSUE BY MICRO-HPLC WITH FLUORESCENCE-DETECTION
    JOCHHEIM, C
    LINSCHEID, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 711 - 711
  • [50] Mixed-mode reversed-phase and ion-exchange monolithic columns for micro-HPLC
    Jiang, Zhengjin
    Smith, Norman W.
    Ferguson, Paul D.
    Taylor, Mark R.
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (15) : 2774 - 2783