Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study

被引:26
|
作者
Gumrukcu, Zeynep [1 ]
Korkmaz, Yavuz Tolga [1 ]
Korkmaz, Fatih Mehmet [2 ]
机构
[1] Fac Dent, Dept Oral & Maxillofacial Surg, Trabzon, Turkey
[2] Fac Dent, Dept Prosthodont, Trabzon, Turkey
关键词
Sinus augmentation; Tilted implant; Stress analysis; Bone type; Von Mises stress; SHORT DENTAL IMPLANTS; RETAINED OVERDENTURES; STRESS-DISTRIBUTION; CORTICAL BONE; LENGTH; STABILITY; QUALITY; THICKNESS; DIAMETER; SURVIVAL;
D O I
10.1016/j.compbiomed.2017.04.015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and Objective: The purpose of this study is to evaluate and compare bone stress that occurs as a result of using vertical implants with simultaneous sinus augmentation with bone stress generated from oblique implants without sinus augmentation in atrophic maxilla. Methods: Six, three-dimensional (3D) finite element (FE) models of atrophic maxilla were generated with SolidWorks software. The maxilla models were varied for two different bone types. Models 2a, 2b and 2c represent maxilla models with D2 bone type. Models 3a, 3b and 3c represent maxilla models with D3 bone type. Five implants were embedded in each model with different configurations for vertical implant insertion with sinus augmentation: Model 2a/Model 3a, 30 degrees tilted insertion; Model 2b/Model 3b and 45 degrees tilted insertion; Model 2c/Model 3c. A 150 N load was applied obliquely on the hybrid prosthesis. The maximum von Mises stress values were comparatively evaluated using color scales. Results: The von Mises stress values predicted by the FE models were higher for all D3 bone models in both cortical and cancellous bone. For the vertical implant models, lower stress values were found in cortical bone. Tilting of the distal implants by 30 degrees increased the stress in the cortical layer compared to vertical implant models. Tilting of the distal implant by 45 degrees decreased the stress in the cortical bone compared to the 30 degrees models, but higher stress values were detected in the 45 degrees models compared to the vertical implant models. Conclusions: Augmentation should be the first treatment option in atrophic maxilla in terms of biomechanics. Tilted posterior implants can create higher stress values than vertical posterior implants. During tilting implant planning, the use of a 45 degrees tilted implant results in better biomechanical performance in peri-implant bone than 30 degrees tilted implant due to the decrease in cantilever length.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [31] Optimal biomechanical choice of implant placement in various pilon fracture types: a finite element study
    Liu, Peizhao
    Mei, Xianzhong
    Wang, Zhixiang
    Xu, Feng
    Cai, Xianhua
    Shou, Kangquan
    Wei, Shijun
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [32] A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis
    Song, Ho-Yong
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (04): : 304 - 312
  • [33] The Influence of Various Superstructure Materials on Stress Distribution for Implant-Supported Prosthesis: Three-Dimensional Finite Element Analysis
    Jameel, Rawan Mufeed
    Al-Khafaji, Aseel Mohammed
    PROSTHESIS, 2024, 6 (05): : 1133 - 1148
  • [34] Comparison of the Crestal Bone Loss Between Implant-Supported Prosthesis With Sinus Augmentation and Distal Cantilevered Implant-Supported Prosthesis Without Sinus Augmentation
    Dereci, Omur
    Mumcu, Emre
    Kosar, Yasin Caglar
    Fadhil, Sadeq Mohammed Taqi
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (05) : 401 - 406
  • [35] Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Souto Borges, Alexandre Luiz
    Rodrigues, Vinicius Aneas
    Bottino, Marco Antonio
    Kleverlaan, Cornelis Johannes
    JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (02): : 67 - 74
  • [36] Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: A finite element analysis
    Huang, Ling-Shiuan
    Huang, Yen-Chang
    Yuan, Cadmus
    Ding, Shinn-Jyh
    Yan, Min
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (01) : 248 - 263
  • [37] Finite Element Analysis of Different Framework Materials on Maxillary Palateless Implant-Supported Overdenture Prosthesis
    Sultanoglu, Elifnur Guezelce
    Tokar, Emre
    Karacer, Oezguel
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2023, 43 (03) : 239 - 248
  • [38] Finite Element Analysis of Different Framework Materials on Maxillary Palateless Implant-Supported Overdenture Prosthesis
    Elifnur Güzelce Sultanoğlu
    Emre Tokar
    Özgül Karacer
    Journal of Medical and Biological Engineering, 2023, 43 : 239 - 248
  • [39] Clinical Evaluation of Zygomatic Implant-Supported Fixed and Removable Prosthesis
    Atalay, Belir
    Doganay, Ozge
    Saracoglu, Banu Karayazgan
    Bultan, Ozgur
    Hafiz, Gunter
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (01) : 185 - 189
  • [40] A clinical evaluation of 76 implant-supported superstructures in the composite grafted maxilla
    Kaptein, MLA
    De Putter, C
    De Lange, GL
    Blijdorp, PA
    JOURNAL OF ORAL REHABILITATION, 1999, 26 (08) : 619 - 623