Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study

被引:26
|
作者
Gumrukcu, Zeynep [1 ]
Korkmaz, Yavuz Tolga [1 ]
Korkmaz, Fatih Mehmet [2 ]
机构
[1] Fac Dent, Dept Oral & Maxillofacial Surg, Trabzon, Turkey
[2] Fac Dent, Dept Prosthodont, Trabzon, Turkey
关键词
Sinus augmentation; Tilted implant; Stress analysis; Bone type; Von Mises stress; SHORT DENTAL IMPLANTS; RETAINED OVERDENTURES; STRESS-DISTRIBUTION; CORTICAL BONE; LENGTH; STABILITY; QUALITY; THICKNESS; DIAMETER; SURVIVAL;
D O I
10.1016/j.compbiomed.2017.04.015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and Objective: The purpose of this study is to evaluate and compare bone stress that occurs as a result of using vertical implants with simultaneous sinus augmentation with bone stress generated from oblique implants without sinus augmentation in atrophic maxilla. Methods: Six, three-dimensional (3D) finite element (FE) models of atrophic maxilla were generated with SolidWorks software. The maxilla models were varied for two different bone types. Models 2a, 2b and 2c represent maxilla models with D2 bone type. Models 3a, 3b and 3c represent maxilla models with D3 bone type. Five implants were embedded in each model with different configurations for vertical implant insertion with sinus augmentation: Model 2a/Model 3a, 30 degrees tilted insertion; Model 2b/Model 3b and 45 degrees tilted insertion; Model 2c/Model 3c. A 150 N load was applied obliquely on the hybrid prosthesis. The maximum von Mises stress values were comparatively evaluated using color scales. Results: The von Mises stress values predicted by the FE models were higher for all D3 bone models in both cortical and cancellous bone. For the vertical implant models, lower stress values were found in cortical bone. Tilting of the distal implants by 30 degrees increased the stress in the cortical layer compared to vertical implant models. Tilting of the distal implant by 45 degrees decreased the stress in the cortical bone compared to the 30 degrees models, but higher stress values were detected in the 45 degrees models compared to the vertical implant models. Conclusions: Augmentation should be the first treatment option in atrophic maxilla in terms of biomechanics. Tilted posterior implants can create higher stress values than vertical posterior implants. During tilting implant planning, the use of a 45 degrees tilted implant results in better biomechanical performance in peri-implant bone than 30 degrees tilted implant due to the decrease in cantilever length.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [41] Regenerative approaches for rehabilitation with single implant-supported prosthesis in the maxilla: a comprehensive clinical description
    Henrique Cassebe Ledo Pelegrine
    Gabriela Ezequiel Oliveira
    Luiz Antonio Borelli Barros Filho
    Luiz Antonio Borelli Barros
    Erica Dorigatti de Avila
    Rafael Scaf de Molon
    Periodontal and Implant Research, 8 (1)
  • [42] Attachment-Retained Gingival Prosthesis for Implant-Supported Fixed Dental Prosthesis in the Maxilla: A Clinical Report
    de Mattias Sartori, Ivete Aparecida
    Uhlendorf, Yuri
    Marques Padovan, Luiz Eduardo
    Ribeiro Junior, Paulo Domingos
    Moreira Melo, Ana Claudia
    Tiossi, Rodrigo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08): : 654 - 658
  • [43] The Utility of Implant-Supported Fixed Dental Prosthesis Material for Implant Micromovement and Peri-implant Bone Microstrain: A Study in Rabbit Tibia
    Dieguez-Pereira, Markel
    Brizuela-Velasco, Aritza
    Chavarri-Prado, David
    Perez-Pevida, Esteban
    DeLlanos-Lanchares, Hector
    Alvarez-Arenal, Angel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (06) : 1132 - 1140
  • [44] Finite element analysis applied to a dental implant-supported structure
    Garitaonaindia, U.
    Alcaraz, J. L.
    BIODENTAL ENGINEERING II, 2014, : 25 - 28
  • [45] Analysis of strain at selected bone sites of a cantilevered implant-supported prosthesis
    Tashkandi, EA
    Lang, BR
    Edge, MJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (02): : 158 - 164
  • [46] Stress distribution in bone related to implant-supported prosthesis design.
    Stegaroiu, R
    Sato, T
    Kusakari, II
    Miyakawa, O
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1325 - 1325
  • [47] The effects of bone remodeling on biomechanical behavior in a patient with an implant-supported overdenture
    Sato, Emika
    Shigemitsu, Ryuji
    Mito, Takehiko
    Yoda, Nobuhiro
    Rasmussen, John
    Sasaki, Keiichi
    Computers in Biology and Medicine, 2021, 129
  • [48] Biomechanical Evaluation of Bone Quality Effect on Stresses at Bone-Implant Interface: A Finite Element Study
    Taharou, B.
    Merdji, A.
    Hillstrom, R.
    Benaissa, A.
    Roy, S.
    Della, N.
    Aid, A.
    Mukdadi, O. M.
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2021, 7 (03): : 1266 - 1275
  • [49] The effects of bone remodeling on biomechanical behavior in a patient with an implant-supported overdenture
    Sato, Emika
    Shigemitsu, Ryuji
    Mito, Takehiko
    Yoda, Nobuhiro
    Rasmussen, John
    Sasaki, Keiichi
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 129
  • [50] Effect of Superstructure Materials and Misfit on Stress Distribution in a Single Implant-Supported Prosthesis: A Finite Element Analysis
    Assuncao, Wirley Goncalves
    Gomes, Erica Alves
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Tabata, Lucas Fernando
    Capello de Sousa, Edson Antonio
    JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (03) : 689 - 695