An MRI framework for respiratory motion modelling validation

被引:3
|
作者
Meschini, Giorgia [1 ]
Paganelli, Chiara [1 ]
Vai, Alessandro [2 ]
Fontana, Giulia [2 ]
Molinelli, Silvia [2 ]
Pella, Andrea [2 ]
Vitolo, Viviana [2 ]
Barcellini, Amelia [2 ]
Orlandi, Ester [2 ]
Ciocca, Mario [2 ]
Riboldi, Marco [3 ]
Baroni, Guido [1 ,2 ]
机构
[1] Politecn Milan, Dept Elect Informat & Bioengn, Via G Colombo 40, I-20133 Milan, Italy
[2] Natl Ctr Oncol Hadrontherapy CNAO, Pavia, Italy
[3] Ludwig Maximilians Univ LMU, Dept Med Phys, Garching, Germany
关键词
4DMRI; breathing motion; MRI‐ guidance; radiation oncology imaging; respiratory motion modelling; ORGAN MOTION; IMAGE REGISTRATION; RADIATION-THERAPY; RADIOTHERAPY; MANAGEMENT; PHANTOM; 4DMRI; TOOL;
D O I
10.1111/1754-9485.13175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Respiratory motion models establish a correspondence between respiratory-correlated (RC) 4-dimensional (4D) imaging and respiratory surrogates, to estimate time-resolved (TR) 3D breathing motion. To evaluate the performance of motion models on real patient data, a validation framework based on magnetic resonance imaging (MRI) is proposed, entailing the use of RC 4DMRI to build the model, and on both (i) TR 2D cine-MRI and (ii) additional 4DMRI data for testing intra-/inter-fraction breathing motion variability. Methods Repeated MRI data were acquired in 7 patients with abdominal lesions. The considered model relied on deformable image registration (DIR) for building the model and compensating for inter-fraction baseline variations. Both 2D and 3D validation were performed, by comparing model estimations with the ground truth 2D cine-MRI and 4DMRI respiratory phases, respectively. Results The median DIR error was comparable to the voxel size (1.33 x 1.33 x 5 mm(3)), with higher values in the presence of large inter-fraction motion (median value: 2.97 mm). In the 2D validation, the median estimation error on anatomical landmarks' position resulted below 4 mm in every scenario, whereas in the 3D validation it was 1.33 mm and 4.21 mm when testing intra- and inter-fraction motion, respectively. The range of motion described in the cine-MRI was comparable to the motion of the building 4DMRI, being always above the estimation error. Overall, the model performance was dependent on DIR error, presenting reduced accuracy when inter-fraction baseline variations occurred. Conclusions Results suggest the potential of the proposed framework in evaluating global motion models for organ motion management in MRI-guided radiotherapy.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 50 条
  • [41] A new approach for the validation of skeletal muscle modelling using MRI data
    Markus Böl
    Maike Sturmat
    Christine Weichert
    Cornelia Kober
    Computational Mechanics, 2011, 47 : 591 - 601
  • [42] Sensibilization of a motorcycle simulator to the effects of the roll motion: Modelling and experimental validation
    Di Miceli, Denny
    Bartolozzi, Mirco
    Berzi, Lorenzo
    Savino, Giovanni
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2023, 237 (14) : 3519 - 3535
  • [43] Motion resistance modelling and validation in winter conditions with varying air drag
    Askerdal, M.
    Fredriksson, J.
    Laine, L.
    Bruzelius, F.
    VEHICLE SYSTEM DYNAMICS, 2024,
  • [44] Estimating joint kinematics from skin motion observation: modelling and validation
    Wolf, Alon
    Senesh, Merav
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (11) : 939 - 946
  • [45] Advanced Framework for Fetal Diffusion MRI: Dynamic Distortion and Motion Correction
    Snoussi, Haykel
    Karimi, Davood
    Afacan, Onur
    Utkur, Mustafa
    Gholipour, Ali
    PERINATAL, PRETERM AND PAEDIATRIC IMAGE ANALYSIS, PIPPI 2024, 2025, 14747 : 35 - 45
  • [46] Framework for the evaluation of interplay effects between respiratory motion and dose application
    Von Muenchow, A.
    Straub, K.
    Hofmaier, J.
    Freislederer, P.
    Reiner, M.
    Thieke, C.
    Soehn, M.
    Alber, M.
    Floca, R.
    Belka, C.
    Parodi, K.
    Kamp, F.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S886 - S887
  • [47] Development of closed-loop modelling framework for adaptive respiratory pacemakers
    Ai, Weiwei
    Suresh, Vinod
    Roop, Partha S.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 141
  • [48] MRI of pediatric ovarian masses: validation of the O-RADS framework
    Munari, Alice M.
    Monti, Caterina B.
    Viglio, Camilla
    Folco, Gianluca
    Rizzetto, Francesco
    Zirpoli, Salvatore
    EUROPEAN RADIOLOGY, 2025,
  • [49] Evaluation of residual abdominal tumour motion in carbon ion gated treatments through respiratory motion modelling
    Meschini, Giorgia
    Seregni, Matteo
    Pella, Andrea
    Ciocca, Mario
    Fossati, Piero
    Valvo, Francesca
    Riboldi, Marco
    Baroni, Guido
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 28 - 37
  • [50] Empirical validation of a quality framework for evaluating modelling languages in MDE environments
    Giraldo, Faber D.
    Chicaiza, Angela J.
    Espana, Sergio
    Pastor, Oscar
    SOFTWARE QUALITY JOURNAL, 2021, 29 (02) : 275 - 307