An MRI framework for respiratory motion modelling validation

被引:3
|
作者
Meschini, Giorgia [1 ]
Paganelli, Chiara [1 ]
Vai, Alessandro [2 ]
Fontana, Giulia [2 ]
Molinelli, Silvia [2 ]
Pella, Andrea [2 ]
Vitolo, Viviana [2 ]
Barcellini, Amelia [2 ]
Orlandi, Ester [2 ]
Ciocca, Mario [2 ]
Riboldi, Marco [3 ]
Baroni, Guido [1 ,2 ]
机构
[1] Politecn Milan, Dept Elect Informat & Bioengn, Via G Colombo 40, I-20133 Milan, Italy
[2] Natl Ctr Oncol Hadrontherapy CNAO, Pavia, Italy
[3] Ludwig Maximilians Univ LMU, Dept Med Phys, Garching, Germany
关键词
4DMRI; breathing motion; MRI‐ guidance; radiation oncology imaging; respiratory motion modelling; ORGAN MOTION; IMAGE REGISTRATION; RADIATION-THERAPY; RADIOTHERAPY; MANAGEMENT; PHANTOM; 4DMRI; TOOL;
D O I
10.1111/1754-9485.13175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Respiratory motion models establish a correspondence between respiratory-correlated (RC) 4-dimensional (4D) imaging and respiratory surrogates, to estimate time-resolved (TR) 3D breathing motion. To evaluate the performance of motion models on real patient data, a validation framework based on magnetic resonance imaging (MRI) is proposed, entailing the use of RC 4DMRI to build the model, and on both (i) TR 2D cine-MRI and (ii) additional 4DMRI data for testing intra-/inter-fraction breathing motion variability. Methods Repeated MRI data were acquired in 7 patients with abdominal lesions. The considered model relied on deformable image registration (DIR) for building the model and compensating for inter-fraction baseline variations. Both 2D and 3D validation were performed, by comparing model estimations with the ground truth 2D cine-MRI and 4DMRI respiratory phases, respectively. Results The median DIR error was comparable to the voxel size (1.33 x 1.33 x 5 mm(3)), with higher values in the presence of large inter-fraction motion (median value: 2.97 mm). In the 2D validation, the median estimation error on anatomical landmarks' position resulted below 4 mm in every scenario, whereas in the 3D validation it was 1.33 mm and 4.21 mm when testing intra- and inter-fraction motion, respectively. The range of motion described in the cine-MRI was comparable to the motion of the building 4DMRI, being always above the estimation error. Overall, the model performance was dependent on DIR error, presenting reduced accuracy when inter-fraction baseline variations occurred. Conclusions Results suggest the potential of the proposed framework in evaluating global motion models for organ motion management in MRI-guided radiotherapy.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 50 条
  • [31] Evaluation of MRI-derived surrogate signals to model respiratory motion
    Tran, Elena H.
    Eiben, Bjorn
    Wetscherek, Andreas
    Oelfke, Uwe
    Meedt, Gustav
    Hawkes, David J.
    McClelland, Jamie R.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [32] A functional MRI study of hypnosis for respiratory motion control during radiotherapy
    Liu, Y.
    Li, R.
    Xie, Y.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1217 - S1217
  • [33] Improved data acquisition efficiency for respiratory motion correction in coronary MRI
    Mehdi H Moghari
    Sébastien Roujol
    Markus Henningsson
    Raymond H Chan
    Susie Hong
    Beth Goddu
    Lois A Goepfert
    Kraig V Kissinger
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [34] Quantication and analysis of respiratory motion from 4D MRI
    Abd Rahni, Ashrani Aizzuddin
    Lewis, Emma
    Wells, Kevin
    9TH NATIONAL SEMINAR ON MEDICAL PHYSICS (NSMP2014), 2014, 546
  • [35] Elliptical subject-specific model of respiratory motion for cardiac MRI
    Burger, Ian
    Meintjes, Ernesta M.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (03) : 722 - 731
  • [36] On the influence of respiratory motion in radial tissue phase mapping cardiac MRI
    Paul, Jan
    Wundrak, Stefan
    Hombach, Vinzenz
    Rottbauer, Wolfgang
    Rasche, Volker
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (05) : 1218 - 1228
  • [37] Characterisation of Respiratory Motion Extracted from 4D MRI
    Abd Rahni, Ashrani Aizzuddin
    Lewis, Emma
    Wells, Kevin
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [38] A back propagation neural network based respiratory motion modelling method
    Jiang, Shan
    Li, Bowen
    Yang, Zhiyong
    Li, Yuhua
    Zhou, Zeyang
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (03):
  • [39] Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET
    Kesner, Adam Leon
    Chung, Jonathan Hero
    Lind, Kimberly Erin
    Kwak, Jennifer Jihyang
    Lynch, David
    Burckhardt, Darrell
    Koo, Phillip Jahhyung
    RADIOLOGY, 2016, 281 (01) : 239 - 248
  • [40] A new approach for the validation of skeletal muscle modelling using MRI data
    Boel, Markus
    Sturmat, Maike
    Weichert, Christine
    Kober, Cornelia
    COMPUTATIONAL MECHANICS, 2011, 47 (05) : 591 - 601