An MRI framework for respiratory motion modelling validation

被引:3
|
作者
Meschini, Giorgia [1 ]
Paganelli, Chiara [1 ]
Vai, Alessandro [2 ]
Fontana, Giulia [2 ]
Molinelli, Silvia [2 ]
Pella, Andrea [2 ]
Vitolo, Viviana [2 ]
Barcellini, Amelia [2 ]
Orlandi, Ester [2 ]
Ciocca, Mario [2 ]
Riboldi, Marco [3 ]
Baroni, Guido [1 ,2 ]
机构
[1] Politecn Milan, Dept Elect Informat & Bioengn, Via G Colombo 40, I-20133 Milan, Italy
[2] Natl Ctr Oncol Hadrontherapy CNAO, Pavia, Italy
[3] Ludwig Maximilians Univ LMU, Dept Med Phys, Garching, Germany
关键词
4DMRI; breathing motion; MRI‐ guidance; radiation oncology imaging; respiratory motion modelling; ORGAN MOTION; IMAGE REGISTRATION; RADIATION-THERAPY; RADIOTHERAPY; MANAGEMENT; PHANTOM; 4DMRI; TOOL;
D O I
10.1111/1754-9485.13175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Respiratory motion models establish a correspondence between respiratory-correlated (RC) 4-dimensional (4D) imaging and respiratory surrogates, to estimate time-resolved (TR) 3D breathing motion. To evaluate the performance of motion models on real patient data, a validation framework based on magnetic resonance imaging (MRI) is proposed, entailing the use of RC 4DMRI to build the model, and on both (i) TR 2D cine-MRI and (ii) additional 4DMRI data for testing intra-/inter-fraction breathing motion variability. Methods Repeated MRI data were acquired in 7 patients with abdominal lesions. The considered model relied on deformable image registration (DIR) for building the model and compensating for inter-fraction baseline variations. Both 2D and 3D validation were performed, by comparing model estimations with the ground truth 2D cine-MRI and 4DMRI respiratory phases, respectively. Results The median DIR error was comparable to the voxel size (1.33 x 1.33 x 5 mm(3)), with higher values in the presence of large inter-fraction motion (median value: 2.97 mm). In the 2D validation, the median estimation error on anatomical landmarks' position resulted below 4 mm in every scenario, whereas in the 3D validation it was 1.33 mm and 4.21 mm when testing intra- and inter-fraction motion, respectively. The range of motion described in the cine-MRI was comparable to the motion of the building 4DMRI, being always above the estimation error. Overall, the model performance was dependent on DIR error, presenting reduced accuracy when inter-fraction baseline variations occurred. Conclusions Results suggest the potential of the proposed framework in evaluating global motion models for organ motion management in MRI-guided radiotherapy.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 50 条
  • [21] Improved respiratory motion self-gating in cardiovascular MRI
    Yu Gao
    Ziwu Zhou
    Fei Han
    Paul J Finn
    Peng Hu
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [22] Gastrointestinal 4D MRI with Respiratory Motion Correction
    Johansson, A.
    Balter, J.
    Cao, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E583 - E584
  • [23] Gastrointestinal 4D MRI with respiratory motion correction
    Johansson, Adam
    Balter, James M.
    Cao, Yue
    MEDICAL PHYSICS, 2021, 48 (05) : 2521 - 2527
  • [24] Quantifying the reduction of respiratory motion by mechanical ventilation with MRI for radiotherapy
    Z. van Kesteren
    J. K. Veldman
    M. J. Parkes
    M. F. Stevens
    P. Balasupramaniam
    J. G. van den Aardweg
    G. van Tienhoven
    A. Bel
    I. W. E. M. van Dijk
    Radiation Oncology, 17
  • [25] Respiratory Motion Modelling and Prediction Using Probability Density Estimation
    Alnowam, Majdi R.
    Lewis, E.
    Guy, M.
    Wells, K.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2465 - 2469
  • [26] Dense Motion Propogation from Sparse Samples for Free Breathing Respiratory Motion Modelling
    Smith, Rhodri L.
    Dasari, Paul
    Lindsay, Cliff
    King, Michael
    Wells, Kevin
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [27] Correlation between external and internal respiratory motion: a validation study
    Ernst, Floris
    Bruder, Ralf
    Schlaefer, Alexander
    Schweikard, Achim
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (03) : 483 - 492
  • [28] Correlation between external and internal respiratory motion: a validation study
    Floris Ernst
    Ralf Bruder
    Alexander Schlaefer
    Achim Schweikard
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 483 - 492
  • [29] A framework combining image registration, respiratory motion models, and motion compensated image reconstruction
    McClelland, J.
    Modat, M.
    Champion, B. A. S.
    Kaza, E.
    Collins, D. J.
    Leach, M. O.
    Hawkes, D. J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S811 - S811
  • [30] THE DEVELOPMENT OF EQUIPMENT FOR THE TECHNICAL ASSESSMENT OF RESPIRATORY MOTION INDUCED ARTIFACTS IN MRI
    JACKSON, PC
    DAVIES, SC
    ZANANIRI, FV
    BEAN, JP
    FOLLETT, DH
    HALLIWELL, M
    WELLS, PNT
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (782): : 132 - 139