Performance of the automated Abbott RealTime™ HIV-1 assay on a genetically diverse panel of specimens from London:: Comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx® HIV RNA quantitative assays

被引:44
|
作者
Swanson, Priscilla
Holzmayer, Vera
Huang, Shihai
Hay, Phillip
Adebiyi, Ade
Rice, Philip
Abravaya, Klara
Thamm, Sven
Devare, Sushil G.
Hackett, John, Jr.
机构
[1] Abbott Labs, AIDS Res & Retrovirus Discovery, Abbott Pk, IL 60064 USA
[2] Abbott Mol Inc, Des Plaines, IL USA
[3] Univ London St Georges Hosp, Courtyard Clin, London SW17 0RE, England
关键词
real-time RT-PCR; HIV-1 viral load; HIV-1 genetic diversity;
D O I
10.1016/j.jviromet.2006.06.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Automated RNA extraction and quantitation of HIV-1 by real-time PCR offer potential advantages of efficient sample processing, improved sensitivity, expanded dynamic range and reduced contamination risk. In this study, plasma was collected from 100 HIV-1 infected patients visiting The Courtyard Clinic of St. George's Hospital in London, United Kingdom (UK). Viral loads measured using the automated Abbott RealTime HIV-1 assay (m2000sp sample preparation and m2000rt (TM) amplification and detection instruments) were compared to results obtained with Versant HIV-1 RNA 3.0 (bDNA), AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) and LCx HIV RNA Quantitative (LCx HIV) assays. Based on gag p24, pol integrase, and env gp41 sequences, the panel included 26 subtype A, 20B, 27C, 10D, 1CRF01_AE, 3 CRF02_AG and 13 recombinant viruses. RealTime HIV-1, bDNA, Monitor v 1.5 and LCx HIV quantitated 82,74, 82, and 83% of samples, respectively, with 82, 71,69 and 80 of the 100 samples measured within the dynamic ranges. Viral loads were highly correlated with 99% of values within 1 log(10) copies/ml between tests. The automated m2000 system and RealTime HIV-1 assay can increase laboratory throughput, enhance overall efficiency and reduce operator-associated errors while providing reliable quantitation of genetically diverse strains of HIV-1. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [1] Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT
    Swanson, P
    de Mendoza, C
    Joshi, Y
    Golden, A
    Hodinka, RL
    Soriano, V
    Devare, SG
    Hackett, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (08) : 3860 - 3868
  • [2] Comprehensive comparison of the VERSANT® HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 MONITOR® 1.5 assays on 1000 clinical specimens
    Galli, R
    Merrick, L
    Friesenhahn, M
    Ziermann, R
    JOURNAL OF CLINICAL VIROLOGY, 2005, 34 (04) : 245 - 252
  • [3] Evaluation of performance across the dynamic range of the Abbott RealTime™ HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses
    Swanson, Priscilla
    Huang, Shihai
    Abravaya, Klara
    de Mendoza, Carmen
    Soriano, Vincent
    Devare, Sushil G.
    Hackett, John, Jr.
    JOURNAL OF VIROLOGICAL METHODS, 2007, 141 (01) : 49 - 57
  • [4] Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays-LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5
    Katsoulidou, A
    Petrodaskalaki, M
    Sypsa, V
    Papachristou, E
    Anastassopoulou, CG
    Gargalianos, P
    Karafoulidou, A
    Lazanas, M
    Kordossis, T
    Andoniadou, A
    Hatzakis, A
    JOURNAL OF VIROLOGICAL METHODS, 2006, 131 (02) : 168 - 174
  • [5] Comparative evaluation of the Abbott HIV-1 RealTime™ assay with the Standard Roche COBAS® Amplicor™ HIV-1 Monitor® Test, v1.5 for determining HIV-1 RNA levels in plasma specimens from Pune, India
    Khopkar, Priyanka
    Mallav, Vikas
    Chidrawar, Shweta
    Kulkarni, Smita
    JOURNAL OF VIROLOGICAL METHODS, 2013, 191 (01) : 82 - 87
  • [6] Method Comparison between the Siemens VERSANT® HIV-1 RNA 1.5 Assay (kPCR)* and the Abbott REALTIME HIV-1 Assay
    Monga, D.
    Wagner, C.
    Gorrin, G.
    Baublitz, Y.
    Kritikos, G.
    Mosner, J.
    JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : S101 - S101
  • [7] Performance of the Abbott RealTime HIV-1 assay versus the Roche Amplicor HIV-1 MonitorTM Test, v1.5, UltraSensitive assay for samples with low plasma HIV-1 RNA copy numbers
    Stephan, Christoph
    Hill, Andrew
    Hadacek, Maria Blanca
    van Delft, Yvonne
    Moecklinghoff, Christiane
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2014, 69 (06) : 1708 - 1710
  • [8] Performance of the Automated COBAS AmpliPrep/COBAS TaqMan HIV-1 Test on a Genetically Diverse Panel of Specimens from China: Comparison to the COBAS Amplicor HIV-1 Monitor Test, v1.5
    Xu, Sihong
    Song, Aijing
    Li, Xiuhua
    Nie, Jianhui
    Zhang, Chuntao
    Wang, Youchun
    INTERVIROLOGY, 2010, 53 (04) : 221 - 228
  • [9] Method Comparison Between the VERSANT® HIV-1 RNA 1.0 Assay (kPCR) and the Abbott RealTime™ HIV-1 Assay
    Gonin, G. M.
    Yao, J. D.
    Wagner, C.
    Lin, C.
    Swiatkowski, P.
    Tam, S. M.
    Canchola, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [10] Performance of the automated Abbott RealTime™ HIV-1 assay on a genetically diverse panel of specimens from Brazil
    Swanson, Priscilla
    Huang, Shihai
    Holzmayer, Vera
    Bodelle, Pierre
    Yamaguchi, Julie
    Brennan, Catherine
    Badaro, Roberto
    Brites, Carlos
    Abravaya, Klara
    Devare, Sushil G.
    Hackett, John, Jr.
    JOURNAL OF VIROLOGICAL METHODS, 2006, 134 (1-2) : 237 - 243