Imaging of Soft Tissues Adjacent to Orthopedic Hardware: Comparison of 3-T and 1.5-T MRI

被引:28
|
作者
Farrelly, Cormac [1 ]
Davarpanah, Amir [2 ]
Brennan, Stephen [3 ]
Sampson, Mathew [4 ]
Eustace, Stephen J. [1 ]
机构
[1] Cappagh Natl Orthopaed Hosp, Dept Radiol, Dublin 11, Ireland
[2] Northwestern Univ Hosp, Dept Radiol, Feinberg Sch Med, Chicago, IL USA
[3] Cappagh Natl Orthopaed Hosp, Dept Orthoped Surg, Dublin 11, Ireland
[4] Sports Surg Clin, Dept Radiol, Dublin, Ireland
关键词
1.5; T; 3; artifact reduction; MRI; susceptibility; TOTAL HIP-ARTHROPLASTY; MUSCULOSKELETAL MRI; METALLIC IMPLANTS; SPIN-ECHO; ARTIFACTS; REPLACEMENT; EXPERIENCE; REDUCTION; IMAGES; 3.0T;
D O I
10.2214/AJR.08.1740
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare metal artifact reduction techniques at 1.5-T and 3-T MRI. MATERIALS AND METHODS. A titanium plate with steel screws was placed in a freshly harvested pig leg. The leg was imaged with 1.5-T and 3-T MRI. A T2-weighted turbo spin-echo sequence was used with echo-train lengths of 8, 16, 32, and 64 and a constant readout bandwidth of 31.2 kHz. The images were compared qualitatively, and the optimal echotrain length was selected. Images were acquired at the optimal echo-train length with four different readout bandwidths. Artifact was measured quantitatively, and image quality was ranked qualitatively. The qualitatively best image acquired at 1.5 T was compared with the qualitatively highest-ranked image acquired at 3 T. RESULTS. At both 1.5 T and 3 T, optimal images of equal quality were produced at echotrain lengths of 8 and 16. At higher readout bandwidths, there was quantitatively less artifact. The qualitatively best images were acquired at a readout bandwidth of 31.2 kHz at 1.5 T and 62.5 kHz at 3 T (Cronbach's alpha = 1.00). The optimal image at 3 T was qualitatively superior to that at 1.5 T. CONCLUSION. Optimizing image acquisition parameters in this phantom model resulted in similar quantitative susceptibility artifact at 3 T and 1.5 T and better qualitative images at 3 T than at 1.5 T.
引用
收藏
页码:W60 / W64
页数:5
相关论文
共 50 条
  • [21] Comparison Between Arthroscopic Findings and 1.5-T and 3-T MRI of Oblique Coronal and Sagittal Planes of the Knee for Evaluation of Selective Bundle Injury of the Anterior Cruciate Ligament
    Park, Hee Jin
    Kim, Sam Soo
    Lee, So Yeon
    Park, Noh Hyuck
    Ahn, Jin Hwan
    Chung, Eun Chul
    Park, Ji Yeon
    Kim, Mi-Sung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : W199 - W206
  • [22] Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy
    Xin Kang
    Mieke M. Cannie
    Owen J. Arthurs
    Valerie Segers
    Catherine Fourneau
    Elisa Bevilacqua
    Teresa Cos Sanchez
    Neil J. Sebire
    Jacques C. Jani
    European Radiology, 2017, 27 : 3542 - 3553
  • [23] Is Dedicated Extremity 1.5-T MRI Equivalent to Standard Large-Bore 1.5-T MRI for Foot and Knee Examinations?
    Sutter, Reto
    Tresch, Florian
    Buck, Florian M.
    Pfirrmann, Christian W. A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : 1293 - 1302
  • [24] Editorial Comment: Additional Neonatal Anthropometric Data Support the Safety Profile of Fetal MRI at Both 1.5-T and 3-T Magnet Strengths
    Didier, Ryne A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (05)
  • [25] Skeletal muscle mass and sarcopenia can be determined with 1.5-T and 3-T neck MRI scans, in the event that no neck CT scan is performed
    Zwart, Aniek T.
    Becker, Jan-Niklas
    Lamers, Maria J.
    Dierckx, Rudi A. J. O.
    de Bock, Geertruida H.
    Halmos, Gyorgy B.
    van der Hoorn, Anouk
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 4053 - 4062
  • [26] Skeletal muscle mass and sarcopenia can be determined with 1.5-T and 3-T neck MRI scans, in the event that no neck CT scan is performed
    Aniek T. Zwart
    Jan-Niklas Becker
    Maria J. Lamers
    Rudi A. J. O. Dierckx
    Geertruida H. de Bock
    Gyorgy B. Halmos
    Anouk van der Hoorn
    European Radiology, 2021, 31 : 4053 - 4062
  • [27] Utility of 3-T FLAIR and 3D short tau inversion recovery MR imaging in the preoperative diagnosis of hippocampal sclerosis: Direct comparison with 1.5-T FLAIR MR imaging
    Hashiguchi, Kimiaki
    Morioka, Takato
    Murakami, Nobuya
    Suzuki, Satoshi O.
    Hiwatashi, Akio
    Yoshiura, Takashi
    Sasaki, Tomio
    EPILEPSIA, 2010, 51 (09) : 1820 - 1828
  • [28] A comparison of conventional spin-echo and turbo spin-echo imaging of soft tissues adjacent to orthopedic hardware
    Eustace, S
    Jara, H
    Goldberg, R
    Fenlon, H
    Mason, M
    Melhem, ER
    Yucel, EK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 455 - 458
  • [29] Comparison of 1.5-and 3-T MR imaging for evaluating the articular cartilage of the knee
    Van Dyck, Pieter
    Kenis, Christoph
    Vanhoenacker, Filip M.
    Lambrecht, Valerie
    Wouters, Kristien
    Gielen, Jan L.
    Dossche, Lieven
    Parizel, Paul M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (06) : 1376 - 1384
  • [30] A COMPARISON OF DEFAULT AND REDUCED BANDWIDTH MR IMAGING OF THE SPINE AT 1.5-T
    KETONEN, L
    TOTTERMAN, S
    SIMON, JH
    FOSTER, TH
    KIDO, DK
    SZUMOWSKI, J
    JOY, SE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1990, 11 (01) : 9 - 15