Glucose monitoring by microdialysis: performance in a multicentre study

被引:8
|
作者
Nielsen, J. K. [1 ]
Freckmann, G. [2 ]
Kapitza, C.
Ocvirk, G.
Koelker, K. H.
Kamecke, U. [3 ]
Gillen, R.
Amann-Zalan, I.
Jendrike, N. [2 ]
Christiansen, J. S. [1 ]
Koschinsky, T. [4 ]
Heinemann, L. [5 ]
机构
[1] Aarhus Univ Hosp, Dept Endocrinol, DK-8000 Aarhus, Denmark
[2] Univ Ulm, Inst Diabet Technol, Ulm, Germany
[3] Metecon GmbH, Stadthaus N1, Mannheim, Germany
[4] Univ Dusseldorf, Dusseldorf, Germany
[5] Profil Inst Stoffwechselforsch, Neuss, Germany
关键词
accuracy; continuous glucose monitoring; microdialysis; variability; CLINICAL ACCURACY; REAL-TIME; SYSTEMS; SENSOR; BLOOD;
D O I
10.1111/j.1464-5491.2009.02750.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of this study was to assess the performance of the Continuous Research Tool (CRT) in a multicentre clinical-experimental study. Methods Three patient groups totalling 28 subjects with diabetes [group A 10 Type 1 (Ulm), group B 10 Type 1 (Neuss), group C eight Type 2 (Aarhus)] participated in this trial. Two CRT microdialysis probes were inserted in parallel in the abdominal subcutaneous tissue for 120 h in each subject. In subjects in group A, glucose excursions were induced on one study day and those in group B underwent a glucose clamp (eu-, hypo- or hyperglycaemic) on one study day. CRT data were calibrated once with a retrospective calibration model based on a run-in time of 24 h and three blood glucose measurements per day. Results All analysable experiments, covering a broad range of blood glucose values, yielded highly accurate data for the complete experimental time with a mean relative absolute difference of 12.8 +/- 6.0% and a predictive residual error sum of squares of 15.6 +/- 6.3 (mean +/- SD). Of all measurement results, 98.2% were in zones A and B of the error grid analysis. The average absolute differences were 1.14 mmol/l for Type 1 and 0.88 mmol/l for Type 2 diabetic patients. Relative absolute differences were 16.0% for Type 1 and 12.6% for Type 2 diabetic patients. Conclusions These results demonstrate that this microdialysis system allows reliable continuous glucose monitoring in patients with diabetes of either type.
引用
收藏
页码:714 / 721
页数:8
相关论文
共 50 条
  • [41] Glucose measurement in interstitial fluid by microdialysis for the calibration of minimally invasive blood glucose monitoring
    Li, Dachao
    Wang, Ridong
    Chong, Hao
    Liu, Yu
    Xu, Kexin
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [42] Continuous glucose monitoring in healthy non-diabetic participants: a multicentre prospective study
    Peters, A.
    Li, Z.
    DuBose, S.
    Beck, R.
    Shah, V.
    Weinstock, R. S.
    Tansey, M.
    Sparling, D.
    Woerner, S.
    Vendrame, F.
    Bergenstal, R.
    Sherr, J.
    Dyer, J. Shine
    Watson, S. E.
    Tamborlane, B.
    DIABETOLOGIA, 2018, 61 : S46 - S46
  • [43] Performance of Continuous Glucose Monitoring in Patients With Observational Study
    Liu, Yanhua
    Zhang, Jianna
    Chun, Xueli
    Gao, Yongli
    Yao, Rong
    Liang, Yin
    Zhu, Ling
    He, Ying
    Huang, Wenxia
    ENDOCRINE PRACTICE, 2024, 30 (09) : 795 - 801
  • [44] Microdialysis-based 48-hour continuous glucose monitoring with GlucoDay™:: Clinical performance and patients' acceptance
    Kubiak, T.
    Woerle, B.
    Kuhr, B.
    Nied, I.
    Glaesner, G.
    Hermanns, N.
    Kulzer, B.
    Haak, T.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2006, 8 (05) : 570 - 575
  • [45] USE OF THE MICRODIALYSIS TECHNIQUE IN THE MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE-CONCENTRATION
    MEYERHOFF, C
    BISCHOF, F
    MENNEL, FJ
    STERNBERG, F
    PFEIFFER, EF
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (05): : 268 - 275
  • [46] A Multistep Algorithm for Processing and Calibration of Microdialysis Continuous Glucose Monitoring Data
    Mahmoudi, Zeinab
    Johansen, Mette Dencker
    Christiansen, Jens Sandahl
    Hejlesen, Ole Kristian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (10) : 825 - 835
  • [47] Microdialysis monitoring of glucose, lactate, glycerol, and pyruvate in patients with diabetic ketoacidosis
    Ciechanowska, Anna
    Ladyzynski, Piotr
    Wojcicki, Jan M.
    Sabalinska, Stanislawa
    Krzymien, Janusz
    Pulawska, Elzbieta
    Karnafel, Waldemar
    Foltynski, Piotr
    Kawiak, Jerzy
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2013, 36 (12): : 869 - 877
  • [48] SUBCUTANEOUS MICRODIALYSIS PROBE COUPLED WITH GLUCOSE BIOSENSOR FOR INVIVO CONTINUOUS MONITORING
    MOSCONE, D
    PASINI, M
    MASCINI, M
    TALANTA, 1992, 39 (08) : 1039 - 1044
  • [49] Microdialysis-Coupled Enzymatic Microreactor for in Vivo Glucose Monitoring in Rats
    Moon, Byeong-Ui
    de Vries, Martin G.
    Cordeiro, Carlos A.
    Westerink, Ben H. C.
    Verpoorte, Elisabeth
    ANALYTICAL CHEMISTRY, 2013, 85 (22) : 10949 - 10955
  • [50] Monitoring blood glucose with microdialysis of interstitial fluid in critically ill children
    Vlasselaers, Dirk
    Schau, Lukas
    van den Heuvel, Ingeborg
    Mader, Julia
    Bodenlenz, Manfred
    Suppan, Maria
    Wouters, Pieter
    Ellmeree, Martin
    Van den Berghe, Greet
    CLINICAL CHEMISTRY, 2007, 53 (03) : 536 - 537