Microdialysis-Coupled Enzymatic Microreactor for in Vivo Glucose Monitoring in Rats

被引:23
|
作者
Moon, Byeong-Ui [1 ]
de Vries, Martin G. [1 ,2 ]
Cordeiro, Carlos A. [2 ]
Westerink, Ben H. C. [1 ,2 ]
Verpoorte, Elisabeth [1 ]
机构
[1] Univ Groningen, Groningen Res Inst Pharm, NL-9700 AD Groningen, Netherlands
[2] Brains On Line BV, NL-9701 EA Groningen, Netherlands
关键词
SUBCUTANEOUS ADIPOSE-TISSUE; BLOOD-GLUCOSE; INTERSTITIAL GLUCOSE; INSULIN; SYSTEM; SENSOR; HYPOGLYCEMIA; MEMBRANES; GLUTAMATE; FALL;
D O I
10.1021/ac402414m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous glucose monitoring (CGM) is an important aid for diabetic patients to optimize glycemic control and to prevent long-term complications. However, current CGM devices need further miniaturization and improved functional performance. We have coupled a previously described microfluidic chip with enzymatic microreactor (EMR) to a microdialysis probe and evaluated the performance of this system for monitoring subcutaneous glucose concentration in rats. Nanoliter volumes of microdialysis sample are efficiently reacted with continuously supplied glucose oxidase (GOx) solution in the EMR. The hydrogen peroxide produced is amperometrically detected at a (polypyrrole (PPy)-protected) thin-film Pt electrode. Subcutaneous glucose concentration was continuously monitored in anesthetized rats in response to intravenous injections of 20% glucose (w/v), 5 U/kg insulin, or saline as a control. In vitro evaluation showed a linear range of 2.1-20.6 mM and a sensitivity of 7.8 +/- 1.0 nA/mM (n = 6). The physical lag time between microdialysis and the analytical signal was approximately 18 min. The baseline concentration of blood glucose was 10.2 +/- 2.3 mM. After administering glucose to the rats, glucose levels increased by about 2 mM to 12.1 +/- 2.3 mM in blood and 11.9 +/- 1.5 mM in subcutaneous interstitial fluid (ISF). After insulin administration, glucose levels decreased by about 8 mM relative to baseline to 2.1 +/- 0.6 mM in blood and 2.1 +/- 0.9 mM in ISF. A microfluidic device with integrated chaotic mixer and EMR has been successfully combined with subcutaneous microdialysis to continuously monitor glucose in rats. This proof-of-principle demonstrates the feasibility of improved miniaturization in CGM based on microfluidics.
引用
收藏
页码:10949 / 10955
页数:7
相关论文
共 50 条
  • [1] In vivo real-time monitoring of anti-factor Xa level using a microdialysis-coupled microfluidic device
    Zhou, Xingbei
    Ding, Tao
    Wang, Shushui
    Wen, Longping
    TALANTA OPEN, 2021, 4
  • [2] Detection of glucose, galactose, and lactose in milk with a microdialysis-coupled flow injection amperometric sensor
    Rajendran, V
    Irudayaraj, J
    JOURNAL OF DAIRY SCIENCE, 2002, 85 (06) : 1357 - 1361
  • [3] Microdialysis and biosensors: The in vivo monitoring of glucose
    Moscone, D
    Poscia, A
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 85 - 89
  • [4] A MICRODIALYSIS PROBE COUPLED WITH A MINIATURIZED THERMAL GLUCOSE SENSOR FOR IN-VIVO MONITORING
    AMINE, A
    DIGUA, K
    XIE, B
    DANIELSSON, B
    ANALYTICAL LETTERS, 1995, 28 (13) : 2275 - 2286
  • [5] MICRODIALYSIS COUPLED WITH GLUCOSE BIOSENSORS FOR SUBCUTANEOUS MONITORING
    MOSCONE, D
    MASCINI, M
    ANALUSIS, 1993, 21 (02) : M40 - M42
  • [6] MICRODIALYSIS AND GLUCOSE BIOSENSOR FOR IN-VIVO MONITORING
    MOSCONE, D
    MASCINI, M
    ANNALES DE BIOLOGIE CLINIQUE, 1992, 50 (05) : 323 - 327
  • [7] Wearable microdialysis system for continuous in vivo monitoring of glucose
    Vering, T
    Adam, S
    Drewer, H
    Dumschat, C
    Steinkuhl, R
    Schulze, A
    Siegel, EG
    Knoll, M
    ANALYST, 1998, 123 (07) : 1605 - 1609
  • [8] SUBCUTANEOUS MICRODIALYSIS PROBE COUPLED WITH GLUCOSE BIOSENSOR FOR INVIVO CONTINUOUS MONITORING
    MOSCONE, D
    PASINI, M
    MASCINI, M
    TALANTA, 1992, 39 (08) : 1039 - 1044
  • [9] Microdialysis Coupled with LC-MS/MS for In Vivo Neurochemical Monitoring
    Zestos, Alexander G.
    Kennedy, Robert T.
    AAPS JOURNAL, 2017, 19 (05): : 1284 - 1293
  • [10] Microdialysis coupled to online enzymatic assays
    Obrenovitch, TP
    Zilkha, E
    METHODS, 2001, 23 (01) : 63 - 71