Glucose monitoring by microdialysis: performance in a multicentre study

被引:8
|
作者
Nielsen, J. K. [1 ]
Freckmann, G. [2 ]
Kapitza, C.
Ocvirk, G.
Koelker, K. H.
Kamecke, U. [3 ]
Gillen, R.
Amann-Zalan, I.
Jendrike, N. [2 ]
Christiansen, J. S. [1 ]
Koschinsky, T. [4 ]
Heinemann, L. [5 ]
机构
[1] Aarhus Univ Hosp, Dept Endocrinol, DK-8000 Aarhus, Denmark
[2] Univ Ulm, Inst Diabet Technol, Ulm, Germany
[3] Metecon GmbH, Stadthaus N1, Mannheim, Germany
[4] Univ Dusseldorf, Dusseldorf, Germany
[5] Profil Inst Stoffwechselforsch, Neuss, Germany
关键词
accuracy; continuous glucose monitoring; microdialysis; variability; CLINICAL ACCURACY; REAL-TIME; SYSTEMS; SENSOR; BLOOD;
D O I
10.1111/j.1464-5491.2009.02750.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of this study was to assess the performance of the Continuous Research Tool (CRT) in a multicentre clinical-experimental study. Methods Three patient groups totalling 28 subjects with diabetes [group A 10 Type 1 (Ulm), group B 10 Type 1 (Neuss), group C eight Type 2 (Aarhus)] participated in this trial. Two CRT microdialysis probes were inserted in parallel in the abdominal subcutaneous tissue for 120 h in each subject. In subjects in group A, glucose excursions were induced on one study day and those in group B underwent a glucose clamp (eu-, hypo- or hyperglycaemic) on one study day. CRT data were calibrated once with a retrospective calibration model based on a run-in time of 24 h and three blood glucose measurements per day. Results All analysable experiments, covering a broad range of blood glucose values, yielded highly accurate data for the complete experimental time with a mean relative absolute difference of 12.8 +/- 6.0% and a predictive residual error sum of squares of 15.6 +/- 6.3 (mean +/- SD). Of all measurement results, 98.2% were in zones A and B of the error grid analysis. The average absolute differences were 1.14 mmol/l for Type 1 and 0.88 mmol/l for Type 2 diabetic patients. Relative absolute differences were 16.0% for Type 1 and 12.6% for Type 2 diabetic patients. Conclusions These results demonstrate that this microdialysis system allows reliable continuous glucose monitoring in patients with diabetes of either type.
引用
收藏
页码:714 / 721
页数:8
相关论文
共 50 条
  • [21] MICRODIALYSIS IMPLEMENTED IN THE DESIGN OF A SYSTEM FOR CONTINUOUS GLUCOSE MONITORING
    LAURELL, T
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 323 - 326
  • [22] MICRODIALYSIS PROBE FOR TRANSCUTANEOUS MONITORING OF ETHANOL AND GLUCOSE IN HUMANS
    DEBOER, J
    PLIJTERGROENDIJK, H
    KORF, J
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (06) : 2825 - 2830
  • [23] Wearable microdialysis system for continuous in vivo monitoring of glucose
    Vering, T
    Adam, S
    Drewer, H
    Dumschat, C
    Steinkuhl, R
    Schulze, A
    Siegel, EG
    Knoll, M
    ANALYST, 1998, 123 (07) : 1605 - 1609
  • [24] Subcutaneous glucose monitoring - Microdialysis vs. intracorporeal
    Ward, WK
    DIABETES CARE, 2002, 25 (02) : 410 - 410
  • [25] OPTIMISING THE GLUCOSE SAMPLING PERFORMANCE OF AN INTRAVASCULAR MICRODIALYSIS-BASED CONTINUOUS GLUCOSE MONITORING DEVICE FOR USE IN HOSPITAL SETTINGS
    Lucarelli, F.
    Scuffi, C.
    Mader, J. K.
    Aberer, F.
    Korsatko, S.
    Pieber, T. R.
    Valgimigli, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A13 - A13
  • [26] Optimising the glucose sampling performance of an intravascular microdialysis-based continuous glucose monitoring device for use in hospital settings
    Mader, J. K.
    Lucarelli, F.
    Scuffi, C.
    Aberer, F.
    Korsatko, S.
    Valgimigli, F.
    Pieber, T. R.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [27] CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM USING INTRAVENOUS MICRODIALYSIS AND GLUCOSE SENSING
    Schaller-Ammann, R.
    Greiner, H.
    Huber, A.
    O'Connell, M.
    Krejci, J.
    Porro, G.
    Korsatko, S.
    Gurban, J.
    Deller, S.
    Brunner, M.
    Berghofer, A.
    Priedl, J.
    Zijlstra, E.
    Heise, T.
    Pieber, T. R.
    Schaupp, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A72 - A72
  • [28] DEVELOPMENT OF A STANDARDIZED APPROACH TO INITIATING CONTINUOUS GLUCOSE MONITORING IN A MULTICENTRE PEDIATRIC STUDY
    Lawson, M. L.
    Richardson, C.
    Muileboom, J.
    Evans, K.
    Landry, A.
    Cormack, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A73 - A73
  • [29] Clinical performance of a low cost near infrared sensor for continuous glucose monitoring applied with subcutaneous microdialysis
    Ben Mohammadi, Lhoucine
    Klotzbuecher, T.
    Sigloch, S.
    Welzel, K.
    Goeddel, M.
    Pieber, T. R.
    Schaupp, L.
    BIOMEDICAL MICRODEVICES, 2015, 17 (04)
  • [30] Clinical performance of a low cost near infrared sensor for continuous glucose monitoring applied with subcutaneous microdialysis
    Lhoucine Ben Mohammadi
    T. Klotzbuecher
    S. Sigloch
    K. Welzel
    M. Goeddel
    T. R. Pieber
    L. Schaupp
    Biomedical Microdevices, 2015, 17