Influence of Pixel Size on Quantification of Airway Wall Thickness in Computed Tomography

被引:11
|
作者
Achenbach, Tobias [1 ]
Weinheimer, Oliver [1 ]
Dueber, Christoph [1 ]
Heussel, Claus Peter [2 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Diagnost Intervent Radiol, D-55101 Mainz, Germany
[2] Univ Heidelberg Hosp, Thoraxklin, Heidelberg, Germany
关键词
computed tomography; airway; quantification; MULTIDETECTOR ROW CT; FIELD-OF-VIEW; IMAGE-RECONSTRUCTION;
D O I
10.1097/RCT.0b013e318190699a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multi-detector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes were performed, and the image resolutions were also compared subjectively. Results: The relative error ranged from 0% (biggest phantom) to 330% (smallest phantom, biggest field of view, smaller matrix, and FWHM). Using IBM, the maximum relative error was 10% in the same setting. For FWHM, the improvement was marginal for most settings with a pixel spacing less than 0.195 x 0.195 x 0.8 mm; however, it still decreases the relative error from 290% to 273.6% for a wall thickness of 0.3 mm and a pixel spacing of 0.076 x 0.076 x 0.8 mm. Conclusions: (1) Using a special technique such as IBM to account for computed tomography's blurring effect in assessing airway wall thickness had the greatest impact on correct quantification. (2),The visual impression and the automatic quantification using the FWHM technique improved marginally by decreasing the voxel size to less than 0.195 x 0.195 x 0.8 mm. (3) The FWHM technique as a model for visual quantification is not reliable for airway wall thicknesses less than 1.5 mm.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [31] Aortic wall thickness assessed by multidetector computed tomography as a predictor of coronary atherosclerosis
    Jeltsch, Martin
    Klass, Oliver
    Klein, Stefan
    Feuerlein, Sebastian
    Aschoff, Andrik J.
    Brambs, Hans-Juergen
    Hoffmann, Martin H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (02): : 209 - 217
  • [32] Computed tomographic measurement of cartilaginous airway wall thickness as a predictor of inspiratory flow resistance
    Washko, GR
    Estepar, RS
    Westin, CF
    Kikinis, R
    Loring, SH
    Reilly, JJ
    CHEST, 2005, 128 (04) : 159S - 159S
  • [33] Integrated Intensity-Based Quantification of Small Airway Dimensions Using Computed Tomography
    Zhao, Y.
    Molloi, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E396 - E396
  • [34] Quantification of Small Airway Dimensions Using High Resolution Computed Tomography: A Phantom Study
    Zhao, Y.
    Hernandez, A.
    Boone, J.
    Molloi, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E549 - E549
  • [35] Software-assisted Computed Tomography Quantification of Airway Remodeling in the Normal Aging Process
    Bommart, Sebastien
    Kovacsik, Helene
    Vachier, Isabelle
    Molinari, Nicolas
    Bourdin, Arnaud
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195 (04) : 540 - 541
  • [36] The influence of reconstruction algorithm on the measurement of airway dimensions using computed tomography
    Wong, Jonathan C.
    Nakano, Yasutaka
    Coxson, Harvey O.
    Mueller, Nestor L.
    Pare, Peter D.
    Hogg, James C.
    MEDICAL IMAGING 2008: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2008, 6916
  • [37] Computed tomography quantification of tracheal abnormalities in COPD and their influence on airflow limitation
    Estrella, Leticia Gallardo
    Pompe, Esther
    Kuhnigk, Jan-Martin
    Lynch, David A.
    Bhatt, Surya P.
    van Ginneken, Bram
    van Rikxoort, Eva Marjolein
    MEDICAL PHYSICS, 2017, 44 (07) : 3594 - 3603
  • [38] COMPUTED SAGITTAL AND CORONAL PIXEL TOMOGRAPHY OF THE THORAX
    CHASEN, MH
    LAMASTERS, DL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (03) : 640 - 640
  • [39] Accurate Segmentation of the Left Ventricle in Computed Tomography Images for Local Wall Thickness Assessment
    Peters, J.
    Lessick, J.
    Kneser, R.
    Waechter, I.
    Vembar, M.
    Ecabert, O.
    Weese, J.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT I, 2010, 6361 : 400 - +
  • [40] Validation of semiautomated and locally resolved aortic wall thickness measurements from computed tomography
    Shang, Eric K.
    Lai, Eric
    Pouch, Alison M.
    Hinmon, Robin
    Gorman, Robert C.
    Gorman, Joseph H., III
    Sehgal, Chandra M.
    Ferrari, Giovanni
    Bavaria, Joseph E.
    Jackson, Benjamin M.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (04) : 1034 - 1040