Influence of Pixel Size on Quantification of Airway Wall Thickness in Computed Tomography

被引:11
|
作者
Achenbach, Tobias [1 ]
Weinheimer, Oliver [1 ]
Dueber, Christoph [1 ]
Heussel, Claus Peter [2 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Diagnost Intervent Radiol, D-55101 Mainz, Germany
[2] Univ Heidelberg Hosp, Thoraxklin, Heidelberg, Germany
关键词
computed tomography; airway; quantification; MULTIDETECTOR ROW CT; FIELD-OF-VIEW; IMAGE-RECONSTRUCTION;
D O I
10.1097/RCT.0b013e318190699a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multi-detector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes were performed, and the image resolutions were also compared subjectively. Results: The relative error ranged from 0% (biggest phantom) to 330% (smallest phantom, biggest field of view, smaller matrix, and FWHM). Using IBM, the maximum relative error was 10% in the same setting. For FWHM, the improvement was marginal for most settings with a pixel spacing less than 0.195 x 0.195 x 0.8 mm; however, it still decreases the relative error from 290% to 273.6% for a wall thickness of 0.3 mm and a pixel spacing of 0.076 x 0.076 x 0.8 mm. Conclusions: (1) Using a special technique such as IBM to account for computed tomography's blurring effect in assessing airway wall thickness had the greatest impact on correct quantification. (2),The visual impression and the automatic quantification using the FWHM technique improved marginally by decreasing the voxel size to less than 0.195 x 0.195 x 0.8 mm. (3) The FWHM technique as a model for visual quantification is not reliable for airway wall thicknesses less than 1.5 mm.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [21] Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging
    Zhao, Lei
    Ma, Xiaohai
    Feuchtner, Gudrun Maria
    Zhang, Chen
    Fan, Zhanming
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1778 - 1785
  • [22] Optical coherence tomography for human airway wall layer identification and quantification
    d'Hooghe, Julia N. S.
    de Bruin, Daniel M.
    Roelofs, Joris J. T. H.
    Annema, Jouke T.
    Bonta, Peter I.
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [23] Optical coherence tomography for the identification and quantification of human airway wall layers
    Goorsenberg, Annika W. M.
    d'Hooghe, J. N. S.
    de Bruin, D. M.
    Roelofs, J. J. T. H.
    Annema, J. T.
    Bonta, P. I.
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [24] Optical coherence tomography for identification and quantification of human airway wall layers
    d'Hooghe, Julia N. S.
    Goorsenberg, Annika W. M.
    de Bruin, Daniel M.
    Roelofs, Joris J. T. H.
    Annema, Jouke T.
    Bonta, Peter I.
    PLOS ONE, 2017, 12 (10):
  • [25] Greater thickness of the aortic wall on postmortem computed tomography compared with antemortem computed tomography: the first longitudinal study
    Okuma, Hidemi
    Gonoi, Wataru
    Ishida, Masanori
    Shintani, Yukako
    Takazawa, Yutaka
    Fukayama, Masashi
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2014, 128 (06) : 987 - 993
  • [26] Greater thickness of the aortic wall on postmortem computed tomography compared with antemortem computed tomography: the first longitudinal study
    Hidemi Okuma
    Wataru Gonoi
    Masanori Ishida
    Yukako Shintani
    Yutaka Takazawa
    Masashi Fukayama
    Kuni Ohtomo
    International Journal of Legal Medicine, 2014, 128 : 987 - 993
  • [27] Optimizing airway wall segmentation and quantification by reducing the influence of adjacent vessels and intravascular contrast material with a modified integral-based algorithm in quantitative computed tomography
    Konietzke, Philip
    Weinheimer, Oliver
    Wagner, Willi L.
    Wuennemann, Felix
    Hintze, Christian
    Biederer, Juergen
    Heussel, Claus P.
    Kauczor, Hans-Ulrich
    Wielpuetz, Mark O.
    PLOS ONE, 2020, 15 (08):
  • [28] 5-Year Change In Airway Wall Thickness In Cigarette Smokers: Clinically Important Changes Derived From Computed Tomography
    Charbonnier, J. -P.
    Pompe, E.
    Moore, C. M.
    Van Rikxoort, E.
    Lynch, D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [29] Quantitative Analysis of Intraventricular Dyssynchrony Using Wall Thickness by Multidetector Computed Tomography
    Truong, Quynh A.
    Singh, Jagmeet P.
    Cannon, Christopher P.
    Sarwar, Ammar
    Nasir, Khurram
    Auricchio, Angelo
    Faletra, Francesco F.
    Sorgente, Antonio
    Conca, Cristina
    Moccetti, Tiziano
    Handschumacher, Mark
    Brady, Thomas J.
    Hoffmann, Udo
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (06) : 772 - 781
  • [30] Aortic wall thickness assessed by multidetector computed tomography as a predictor of coronary atherosclerosis
    Martin Jeltsch
    Oliver Klass
    Stefan Klein
    Sebastian Feuerlein
    Andrik J. Aschoff
    Hans-Jürgen Brambs
    Martin H. Hoffmann
    The International Journal of Cardiovascular Imaging, 2009, 25 : 209 - 217