摘要
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multi-detector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes were performed, and the image resolutions were also compared subjectively. Results: The relative error ranged from 0% (biggest phantom) to 330% (smallest phantom, biggest field of view, smaller matrix, and FWHM). Using IBM, the maximum relative error was 10% in the same setting. For FWHM, the improvement was marginal for most settings with a pixel spacing less than 0.195 x 0.195 x 0.8 mm; however, it still decreases the relative error from 290% to 273.6% for a wall thickness of 0.3 mm and a pixel spacing of 0.076 x 0.076 x 0.8 mm. Conclusions: (1) Using a special technique such as IBM to account for computed tomography's blurring effect in assessing airway wall thickness had the greatest impact on correct quantification. (2),The visual impression and the automatic quantification using the FWHM technique improved marginally by decreasing the voxel size to less than 0.195 x 0.195 x 0.8 mm. (3) The FWHM technique as a model for visual quantification is not reliable for airway wall thicknesses less than 1.5 mm.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [11] Evaluation of Airway Wall Thickness Via High-Resolution Computed Tomography in Mild Intermittent Asthma
    Asker, Selvi
    Asker, Muntecep
    Ozbay, Bulent
    RESPIRATORY CARE, 2014, 59 (04) : 550 - 556
  • [12] QUANTITATION OF WALL THICKNESS BY CINE COMPUTED-TOMOGRAPHY
    MERZ, R
    GARRETT, J
    SCHILLER, N
    LIPTON, M
    CIRCULATION, 1985, 72 (04) : 181 - 181
  • [13] Influence of asthma duration on airway wall thickness
    Mincewicz, Grzegorz
    Wasilewska, Eliza
    Aloszko, Agnieszka
    Kurowski, Wojciech
    Mierzejewska, Ewa
    ALERGIA ASTMA IMMUNOLOGIA, 2006, 11 (02): : 93 - 97
  • [14] Harmonizing the pixel size in retrospective computed tomography radiomics studies
    Mackin, Dennis
    Fave, Xenia
    Zhang, Lifei
    Yang, Jinzhong
    Jones, A. Kyle
    Ng, Chaan S.
    Court, Laurence
    PLOS ONE, 2017, 12 (09):
  • [15] QUANTIFICATION OF MYOCARDIAL INFARCT SIZE BY RADIONUCLIDE COMPUTED TOMOGRAPHY
    BRODY, SL
    KEYES, JW
    LUCCHESI, BR
    CLINICAL RESEARCH, 1978, 26 (05): : A730 - A730
  • [16] QUANTIFICATION OF MYOCARDIAL INFARCT SIZE BY RADIONUCLIDE COMPUTED TOMOGRAPHY
    KEYES, JW
    LEONARD, PF
    BRODY, SL
    SVETKOFF, DJ
    ROGERS, WL
    LUCCHESI, BR
    CIRCULATION, 1977, 56 (04) : 64 - 64
  • [17] Airway wall thickness of allergic asthma caused by weed pollen or house dust mite assessed by computed tomography
    Liu, Liping
    Li, Guangrun
    Sun, Yuemei
    Li, Jian
    Tang, Ningbo
    Dong, Liang
    RESPIRATORY MEDICINE, 2015, 109 (03) : 339 - 346
  • [18] ASSESSMENT OF VENTRICULAR WALL THICKNESS INVIVO BY COMPUTED TRANSMISSION TOMOGRAPHY
    SKIOLDEBRAND, CG
    OVENFORS, CO
    MAVROUDIS, C
    LIPTON, MJ
    CIRCULATION, 1980, 61 (05) : 960 - 965
  • [19] Needle thoracostomy: Implications of computed tomography chest wall thickness
    Givens, ML
    Ayotte, K
    Manifold, C
    ACADEMIC EMERGENCY MEDICINE, 2004, 11 (02) : 211 - 213
  • [20] Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio
    Odry, Benjamin L.
    Kiraly, Atilla P.
    Novak, Carol L.
    Naidich, David P.
    Lerallut, Jean-Francois
    MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2, 2006, 6143