Influence of Pixel Size on Quantification of Airway Wall Thickness in Computed Tomography

被引:11
|
作者
Achenbach, Tobias [1 ]
Weinheimer, Oliver [1 ]
Dueber, Christoph [1 ]
Heussel, Claus Peter [2 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Diagnost Intervent Radiol, D-55101 Mainz, Germany
[2] Univ Heidelberg Hosp, Thoraxklin, Heidelberg, Germany
关键词
computed tomography; airway; quantification; MULTIDETECTOR ROW CT; FIELD-OF-VIEW; IMAGE-RECONSTRUCTION;
D O I
10.1097/RCT.0b013e318190699a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multi-detector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes were performed, and the image resolutions were also compared subjectively. Results: The relative error ranged from 0% (biggest phantom) to 330% (smallest phantom, biggest field of view, smaller matrix, and FWHM). Using IBM, the maximum relative error was 10% in the same setting. For FWHM, the improvement was marginal for most settings with a pixel spacing less than 0.195 x 0.195 x 0.8 mm; however, it still decreases the relative error from 290% to 273.6% for a wall thickness of 0.3 mm and a pixel spacing of 0.076 x 0.076 x 0.8 mm. Conclusions: (1) Using a special technique such as IBM to account for computed tomography's blurring effect in assessing airway wall thickness had the greatest impact on correct quantification. (2),The visual impression and the automatic quantification using the FWHM technique improved marginally by decreasing the voxel size to less than 0.195 x 0.195 x 0.8 mm. (3) The FWHM technique as a model for visual quantification is not reliable for airway wall thicknesses less than 1.5 mm.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [1] Airway wall thickness assessed using computed tomography and optical coherence tomography
    Coxson, Harvey O.
    Quiney, Brendan
    Sin, Don D.
    Xing, Li
    McWilliams, Annette M.
    Mayo, John R.
    Lam, Stephen
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 177 (11) : 1201 - 1206
  • [2] Airway wall thickness in asthma assessed by computed tomography - Relation to clinical indices
    Niimi, A
    Matsumoto, H
    Amitani, R
    Nakano, Y
    Mishima, M
    Minakuchi, M
    Nishimura, K
    Itoh, H
    Izumi, T
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (04) : 1518 - 1523
  • [3] Quantitative computed tomography: emphysema and airway wall thickness by sex, age and smoking
    Grydeland, T. B.
    Dirksen, A.
    Coxson, H. O.
    Pillai, S. G.
    Sharma, S.
    Eide, G. E.
    Gulsvik, A.
    Bakke, P. S.
    EUROPEAN RESPIRATORY JOURNAL, 2009, 34 (04) : 858 - 865
  • [4] Airway wall thickness and airflow limitations in asthma assessed in quantitative computed tomography
    Patyk, Mateusz
    Obojski, Andrzej
    Sokolowska-Dabek, Dabrowka
    Parkitna-Patyk, Martyna
    Zaleska-Dorobisz, Urszula
    THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2020, 14
  • [5] Quantitative Computed Tomography Measures of Emphysema and Airway Wall Thickness Are Related to Respiratory Symptoms
    Grydeland, Thomas B.
    Dirksen, Asger
    Coxson, Harvey O.
    Eagan, Tomas M. L.
    Thorsen, Einar
    Pillai, Sreekumar G.
    Sharma, Sanjay
    Eide, Geir Egil
    Gulsvik, Amund
    Bakke, Per S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181 (04) : 353 - 359
  • [6] Semiautomatic vessel wall detection and quantification of wall thickness in computed tomography images of human abdominal aortic aneurysms
    Shum, Judy
    DiMartino, Elena S.
    Goldhammer, Adam
    Goldman, Daniel H.
    Acker, Leah C.
    Patel, Gopal
    Ng, Julie H.
    Martufi, Giampaolo
    Finol, Ender A.
    MEDICAL PHYSICS, 2010, 37 (02) : 638 - 648
  • [7] Quantification of airway wall contrast enhancement on virtual monoenergetic images from spectral computed tomography
    Bodenberger, Arndt Lukas
    Konietzke, Philip
    Weinheimer, Oliver
    Wagner, Willi Linus
    Stiller, Wolfram
    Weber, Tim Frederik
    Heussel, Claus Peter
    Kauczor, Hans-Ulrich
    Wielpuetz, Mark Oliver
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5557 - 5567
  • [8] Quantification of airway wall contrast enhancement on virtual monoenergetic images from spectral computed tomography
    Arndt Lukas Bodenberger
    Philip Konietzke
    Oliver Weinheimer
    Willi Linus Wagner
    Wolfram Stiller
    Tim Frederik Weber
    Claus Peter Heussel
    Hans-Ulrich Kauczor
    Mark Oliver Wielpütz
    European Radiology, 2023, 33 : 5557 - 5567
  • [9] Long-term Changes in Airway-Wall Thickness on Computed Tomography in Asthmatic Patients
    Matsumoto, H.
    Niimi, A.
    Takemura, M.
    Ueda, T.
    Yamaguchi, M.
    Matsuoka, H.
    Jinnai, M.
    Takeda, T.
    Otsuka, K.
    Oguma, T.
    Handa, T.
    Hirai, T.
    Chin, K.
    Mishima, M.
    JOURNAL OF INVESTIGATIONAL ALLERGOLOGY AND CLINICAL IMMUNOLOGY, 2011, 21 (02) : 113 - 119
  • [10] Effect of Reducing Field of View on Multidetector Quantitative Computed Tomography Parameters of Airway Wall Thickness in Asthma
    Sheshadri, Ajay
    Rodriguez, Alfonso
    Chen, Ryan
    Kozlowski, James
    Burgdorf, Dana
    Koch, Tammy
    Tarsi, Jaime
    Schutz, Rebecca
    Wilson, Brad
    Schechtman, Kenneth
    Leader, Joseph K.
    Hoffman, Eric A.
    Castro, Mario
    Fain, Sean B.
    Gierada, David S.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 584 - 590