Comparison of the Efficacy of Different Arterial Waveform-Derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically III Patients

被引:2
|
作者
Kumar, Nitish [1 ]
Malviya, Deepak [1 ]
Nath, Soumya S. [1 ]
Rastogi, Shivani [1 ]
Upadhyay, Vishal [1 ]
机构
[1] Dr Ram Manohar Lohia Inst Med Sci, Dept Anesthesiol & Crit Care Med, Lucknow, Uttar Pradesh, India
关键词
Cardiac index; Positive end expiratory pressure; Pulse pressure variation; Stroke volume variation; Systolic pressure variation; THERAPY;
D O I
10.5005/jp-journals-10071-23440
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction:This study was conducted to assess fluid responsiveness in critically ill patients to avoid various complications of fluid overload. Material and methods: This study was done in an ICU of a tertiary care hospital after approval from the institute ethical committee over 18 months. A total of 54 consenting adult patients were included In the study. Patients were hemodynamically unstable requiring mechanical ventilation, had acute circulatory failure, or those with at least one clinical sign of inadequate tissue perfusion. All patients were ventilated using tidal volume of 6-8 ml/kg, RR-12-15/minutes, positive end expiratory pressure (PEEP)-5 cm of water, and plateau pressure was kept below 30 cm water. They were sedated throughout the study. The arterial line and the central venous catheter were placed and connected to Vigileo-FloTrac transducer (Edward Lifesciences). Patients were classified into responder and nonresponder groups on the basis of the cardiac Index (CI) after fluid challenge of 10 mL/kg of normal saline over 30 minutes. Pulse pressure variation (PPV), stroke volume variation (SW), and systolic pressure variation (SPV) were assessed and compared at baseline, 30 minutes, and 60 minutes. Results: in our study we found that PPV and SW were significantly lower among responders than nonresponders at 30 minutes and insignificant at 60 minutes. Stroke volume variation was 10.28 +/- 1.76 in the responder compared to 12.28 +/- 4.42 (p = 0.02) at 30 minutes and PPV was 15.28 +/- 6.94 in responders while It was 20.03 +/- 4.35 in nonresponders (p = 0.01). We found SPV was insignificant at all time periods among both groups. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [41] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Messina, Antonio
    Caporale, Mariagiovanna
    Calabro, Lorenzo
    Lionetti, Giulia
    Bono, Daniele
    Matronola, Guia Margherita
    Brunati, Andrea
    Frassanito, Luciano
    Morenghi, Emanuela
    Antonelli, Massimo
    Chew, Michelle S.
    Cecconi, Maurizio
    CRITICAL CARE, 2023, 27 (01)
  • [42] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Antonio Messina
    Mariagiovanna Caporale
    Lorenzo Calabrò
    Giulia Lionetti
    Daniele Bono
    Guia Margherita Matronola
    Andrea Brunati
    Luciano Frassanito
    Emanuela Morenghi
    Massimo Antonelli
    Michelle S. Chew
    Maurizio Cecconi
    Critical Care, 27
  • [43] The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    Wyffels, P. A. H.
    Sergeant, P.
    Wouters, P. F.
    ANAESTHESIA, 2010, 65 (07) : 704 - 709
  • [44] How accurate are different arterial pressure-derived estimates of cardiac output and stroke volume variation measures in critically ill patients?
    B Lamia
    HK Kim
    A Hefner
    D Severyn
    H Gomez
    JC Puyana
    MR Pinsky
    Critical Care, 12 (Suppl 2):
  • [45] Prediction of fluid responsiveness in septic shock patients: comparing automated pulse pressure variation by IntelliVue MP monitor and stroke volume variation by FloTrac™/Vigileo™
    B Khwannimit
    R Bhurayanontachai
    Critical Care, 15 (Suppl 1):
  • [46] Very limited usefulness of pulse pressure variation as a predictor of volume responsiveness in critically ill septic patients
    GG Gavriilidis
    IK Kostakou
    VT Tsagari
    AK Kyriakoudi
    NK Koulouris
    AK Koutsoukou
    Critical Care, 18 (Suppl 1):
  • [47] Stroke Volume and Systolic Pressure Variation Are Poor Predictors of Fluid Responsiveness During Major Pancreatic Surgery.
    Shakeban, Hassan
    Conlon, Niamh
    Boylan, John
    LIVER TRANSPLANTATION, 2014, 20 : S297 - S297
  • [48] Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation
    Suehiro, K.
    Rinka, H.
    Ishikawa, J.
    Fuke, A.
    Arimoto, H.
    Miyaichi, T.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) : 767 - 772
  • [49] Arterial pulse pressure variation predicting fluid responsiveness in critically ill patients (Retraction of vol 30, pg 18, 2008)
    Auler, Jose Otavio C., Jr.
    Galas, Filomena R. B. G.
    Sundin, Marcia R.
    Hajjar, Ludhmila A.
    SHOCK, 2009, 31 (05): : 542 - 542
  • [50] Stroke Volume and Arterial Pressure Fluid Responsiveness in Patients With Elevated Stroke Volume Variation Undergoing Major Vascular Surgery: A Prospective Intervention Study
    Fischer, Arabella
    Menger, Johannes
    Mouhieddine, Mohamed
    Seidel, Mathias
    Edlinger-Stanger, Maximilian
    Bevilacqua, Michele
    Brugger, Jonas
    Hiesmayr, Michael
    Dworschak, Martin
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (03) : 407 - 414