Comparison of the Efficacy of Different Arterial Waveform-Derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically III Patients

被引:2
|
作者
Kumar, Nitish [1 ]
Malviya, Deepak [1 ]
Nath, Soumya S. [1 ]
Rastogi, Shivani [1 ]
Upadhyay, Vishal [1 ]
机构
[1] Dr Ram Manohar Lohia Inst Med Sci, Dept Anesthesiol & Crit Care Med, Lucknow, Uttar Pradesh, India
关键词
Cardiac index; Positive end expiratory pressure; Pulse pressure variation; Stroke volume variation; Systolic pressure variation; THERAPY;
D O I
10.5005/jp-journals-10071-23440
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction:This study was conducted to assess fluid responsiveness in critically ill patients to avoid various complications of fluid overload. Material and methods: This study was done in an ICU of a tertiary care hospital after approval from the institute ethical committee over 18 months. A total of 54 consenting adult patients were included In the study. Patients were hemodynamically unstable requiring mechanical ventilation, had acute circulatory failure, or those with at least one clinical sign of inadequate tissue perfusion. All patients were ventilated using tidal volume of 6-8 ml/kg, RR-12-15/minutes, positive end expiratory pressure (PEEP)-5 cm of water, and plateau pressure was kept below 30 cm water. They were sedated throughout the study. The arterial line and the central venous catheter were placed and connected to Vigileo-FloTrac transducer (Edward Lifesciences). Patients were classified into responder and nonresponder groups on the basis of the cardiac Index (CI) after fluid challenge of 10 mL/kg of normal saline over 30 minutes. Pulse pressure variation (PPV), stroke volume variation (SW), and systolic pressure variation (SPV) were assessed and compared at baseline, 30 minutes, and 60 minutes. Results: in our study we found that PPV and SW were significantly lower among responders than nonresponders at 30 minutes and insignificant at 60 minutes. Stroke volume variation was 10.28 +/- 1.76 in the responder compared to 12.28 +/- 4.42 (p = 0.02) at 30 minutes and PPV was 15.28 +/- 6.94 in responders while It was 20.03 +/- 4.35 in nonresponders (p = 0.01). We found SPV was insignificant at all time periods among both groups. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [21] -444 EFFECT OF VENTILATORY PARAMETERS ON THE MEASUREMENT OF ARTERIAL PRESSURE-DERIVED STROKE VOLUME VARIATION IN MECHANICALLY VENTILATED SURGICAL PATIENTS
    Yhim, Hyung-Been
    Bin Yoon, Soo
    Lee, Hyung-Chul
    Hur, Min
    Jung, Chul-Woo
    ANESTHESIA AND ANALGESIA, 2019, 128 : 944 - 945
  • [22] Comparison Between Changes in Systolic-Pressure Variation and Pulse-Pressure Variation After Passive Leg Raising to Predict Fluid Responsiveness in Postoperative Critically Ill Patients
    Xie, Jin
    Xu, Li
    Peng, Ke
    Chen, Jun
    Wan, Jingjie
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (02) : 459 - 465
  • [23] Assessment fluid responsiveness in septic shock patients: a comparison of automated pulse pressure variation and manually calculated pulse pressure variation
    S Panyawatanaporn
    B Khwannimit
    Critical Care, 16 (Suppl 1):
  • [24] Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    Khwannimit, Bodin
    Bhurayanontachai, Rungsun
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (02) : 64 - 69
  • [25] Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
    Alves de Oliveira-Costa, Clarice Daniele
    Friedman, Gilberto
    Rios Vieira, Silvia Regina
    Fialkow, Lea
    CLINICS, 2012, 67 (07) : 773 - 778
  • [26] Pulse pressure variation as a predictor of fluid responsiveness in mechanically ventilated patients with spontaneous breathing activity: a pragmatic observational study
    Grassi, P.
    Lo Nigro, L.
    Battaglia, K.
    Barone, M.
    Testa, F.
    Berlot, G.
    HEART LUNG AND VESSELS, 2013, 5 (02) : 98 - 109
  • [27] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [28] Pressure controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients
    Ye, Weiguang
    Wang, Bin
    Wei, Limin
    Wang, Tianlong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10963 - 10970
  • [29] The Use of Pulse Pressure Variation and Stroke Volume Variation in Spontaneously Breathing Patients to Assess Dynamic Arterial Elastance and to Predict Arterial Pressure Response to Fluid Administration
    Cecconi, Maurizio
    Monge Garcia, M. Ignacio
    Gracia Romero, Manuel
    Mellinghoff, Johannes
    Caliandro, Francesca
    Grounds, Robert Michael
    Rhodes, Andrew
    ANESTHESIA AND ANALGESIA, 2015, 120 (01): : 76 - 84
  • [30] Use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration
    M Cecconi
    MI Monge García
    M Gracia Romero
    J Mellinghoff
    F Caliandro
    RM Grounds
    A Rhodes
    Critical Care, 18 (Suppl 1):