Comparison of the Efficacy of Different Arterial Waveform-Derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically III Patients

被引:2
|
作者
Kumar, Nitish [1 ]
Malviya, Deepak [1 ]
Nath, Soumya S. [1 ]
Rastogi, Shivani [1 ]
Upadhyay, Vishal [1 ]
机构
[1] Dr Ram Manohar Lohia Inst Med Sci, Dept Anesthesiol & Crit Care Med, Lucknow, Uttar Pradesh, India
关键词
Cardiac index; Positive end expiratory pressure; Pulse pressure variation; Stroke volume variation; Systolic pressure variation; THERAPY;
D O I
10.5005/jp-journals-10071-23440
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction:This study was conducted to assess fluid responsiveness in critically ill patients to avoid various complications of fluid overload. Material and methods: This study was done in an ICU of a tertiary care hospital after approval from the institute ethical committee over 18 months. A total of 54 consenting adult patients were included In the study. Patients were hemodynamically unstable requiring mechanical ventilation, had acute circulatory failure, or those with at least one clinical sign of inadequate tissue perfusion. All patients were ventilated using tidal volume of 6-8 ml/kg, RR-12-15/minutes, positive end expiratory pressure (PEEP)-5 cm of water, and plateau pressure was kept below 30 cm water. They were sedated throughout the study. The arterial line and the central venous catheter were placed and connected to Vigileo-FloTrac transducer (Edward Lifesciences). Patients were classified into responder and nonresponder groups on the basis of the cardiac Index (CI) after fluid challenge of 10 mL/kg of normal saline over 30 minutes. Pulse pressure variation (PPV), stroke volume variation (SW), and systolic pressure variation (SPV) were assessed and compared at baseline, 30 minutes, and 60 minutes. Results: in our study we found that PPV and SW were significantly lower among responders than nonresponders at 30 minutes and insignificant at 60 minutes. Stroke volume variation was 10.28 +/- 1.76 in the responder compared to 12.28 +/- 4.42 (p = 0.02) at 30 minutes and PPV was 15.28 +/- 6.94 in responders while It was 20.03 +/- 4.35 in nonresponders (p = 0.01). We found SPV was insignificant at all time periods among both groups. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [31] A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery
    Piccioni, Federico
    Bernasconi, Filippo
    Tramontano, Giulia T. A.
    Langer, Martin
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 677 - 684
  • [32] The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients
    Hadian, Mehrnaz
    Severyn, Donald A.
    Pinsky, Michael R.
    JOURNAL OF CRITICAL CARE, 2011, 26 (03) : 328.e1 - 328.e8
  • [33] IS THE STROKE VOLUME VARIATION (SSV) AND/OR THE PULSE PRESSURE VARIATION (PPV) CALCULATED WITH THE LIDCO RAPID SUITABLE FOR PREDICTION OF FLUID RESPONSIVENESS?
    Brass, P.
    Latza, J.
    Peters, J.
    Hellmich, M.
    Berendes, E.
    INTENSIVE CARE MEDICINE, 2010, 36 : S201 - S201
  • [34] A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery
    Federico Piccioni
    Filippo Bernasconi
    Giulia T. A. Tramontano
    Martin Langer
    Journal of Clinical Monitoring and Computing, 2017, 31 : 677 - 684
  • [35] Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study
    Vos, Jaap Jan
    Poterman, Marieke
    Salm, Pieternel Papineau
    Van Amsterdam, Kai
    Struys, Michel M. R. F.
    Scheeren, Thomas W. L.
    Kalmar, Alain F.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (11): : 1153 - 1160
  • [36] Evaluation of stroke volume variation and pulse pressure variation as predictors of fluid responsiveness in patients undergoing protective one-lung ventilation
    Fu, Qiang
    Duan, Mingda
    Zhao, Feng
    Mi, Weidong
    DRUG DISCOVERIES AND THERAPEUTICS, 2015, 9 (04): : 296 - 302
  • [37] NONINVASIVE MEASUREMENT OF PULSE AND SYSTOLIC PRESSURE VARIATION USING A FINGER CUFF CORRESPOND WITH INTRA ARTERIAL MEASUREMENTS IN MECHANICALLY VENTILATED PATIENTS
    Lansdorp, B.
    Ouweneel, D.
    Lemson, J.
    Hoeven, J. V. D.
    Pickkers, P.
    INTENSIVE CARE MEDICINE, 2010, 36 : S96 - S96
  • [38] Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure Variation and Stroke Volume Variation for Assessing Fluid Responsiveness
    Joshi, Malini
    Dhakane, Praveen
    Bhosale, Shilpushp J.
    Phulambrikar, Rutuja
    Kulkarni, Atul P.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2022, 26 (02) : 179 - 184
  • [39] PLETH VARIABILITY INDEX, PULSE PRESSURE AND STROKE VOLUME VARIATION DO NOT PREDICT FLUID RESPONSIVENESS IN VENTILATED PATIENTS WITH SEPTIC SHOCK TREATED WITH VASOPRESSORS
    Jagannathan, V. K.
    Sharma, S.
    Finn, P.
    Ryan, J.
    Mullenheim, J. W.
    INTENSIVE CARE MEDICINE, 2011, 37 : S89 - S89
  • [40] Automated stroke volume and pulse pressure variations predict fluid responsiveness in mechanically ventilated patients with obstructive jaundice
    Zhao, Feng
    Wang, Peng
    Pei, Shujun
    Mi, Weidong
    Fu, Qiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (11): : 20751 - 20759