Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study

被引:22
|
作者
Leenen, Jobbe P. L. [1 ,2 ]
Dijkman, Eline M. [1 ]
van Dijk, Joris D. [3 ]
van Westreenen, Henderik L. [1 ]
Kalkman, Cor [4 ]
Schoonhoven, Lisette [5 ,6 ]
Patijn, Gijsbert A. [1 ]
机构
[1] Dept Surg, Isala, Zwolle, Netherlands
[2] Connected Care Ctr, Isala, Zwolle, Netherlands
[3] Isala Acad, Isala, Zwolle, Netherlands
[4] UMC Utrecht, Anesthesiol, Utrecht, Netherlands
[5] UMC Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[6] Univ Southampton, Fac Hlth Sci, Southampton, Hants, England
来源
BMJ OPEN | 2021年 / 11卷 / 02期
关键词
surgery; health & safety; adverse events; pancreatic surgery; hepatobiliary surgery; colorectal surgery; EARLY WARNING SCORES; MORTALITY; COMPLICATIONS; IMPACT; CLASSIFICATION; SAFETY; SYSTEM;
D O I
10.1136/bmjopen-2020-042735
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. Design Observational cohort study. Setting Tertiary teaching hospital. Participants Postoperative abdominal surgical patients (n=30) and nurses (n=23). Interventions Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. Outcomes System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. Results Thirty patients were monitored for a median duration of 81 hours (IQR 47-143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1-4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2-4.8) and satisfaction 3.7 (IQR 3.2-4.8), but agreed on ease of learning at 5.0 (IQR 4.0-5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. Conclusions Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses' ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Nonintrusive Vital Signs Monitoring for Sleep Apnea Patients: A Preliminary Study
    Sadek, Ibrahim
    Seet, Edwin
    Biswas, Jit
    Abdulrazak, Bessam
    Mokhtari, Mounir
    IEEE ACCESS, 2018, 6 : 2506 - 2514
  • [42] Continuous Monitoring of Vital Signs Using Cameras: A Systematic Review
    Selvaraju, Vinothini
    Spicher, Nicolai
    Wang, Ju
    Ganapathy, Nagarajan
    Warnecke, Joana M.
    Leonhardt, Steffen
    Swaminathan, Ramakrishnan
    Deserno, Thomas M.
    SENSORS, 2022, 22 (11)
  • [43] Postanesthesia care by remote monitoring of vital signs in surgical wards
    Boer, Christa
    Touw, Hugo R.
    Loer, Stephan A.
    CURRENT OPINION IN ANESTHESIOLOGY, 2018, 31 (06) : 716 - 722
  • [44] Assessment of the feasibility of an ultra-low power, wireless digital patch for the continuous ambulatory monitoring of vital signs
    Hernandez-Silveira, Miguel
    Ahmed, Kamran
    Ang, Su-Shin
    Zandari, Fahriya
    Mehta, Tinaz
    Weir, Rebecca
    Burdett, Alison
    Toumazou, Chris
    Brett, Stephen J.
    BMJ OPEN, 2015, 5 (05):
  • [45] Vital signs monitoring and nurse-patient interaction: A qualitative observational study of hospital practice
    Cardona-Morrell, M.
    Prgomet, M.
    Lake, R.
    Nicholson, M.
    Harrison, R.
    Long, J.
    Westbrook, J.
    Braithwaite, J.
    Hillman, K.
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2016, 56 : 9 - 16
  • [46] Interpretation of continuously measured vital signs data of COVID-19 patients by nurses and physicians at the general ward: A mixed methods study
    van Goor, Harriet M. R.
    Breteler, Martine J. M.
    Schoonhoven, Lisette
    Kalkman, Cor
    van Loon, Kim
    Kaasjager, Karin A. H.
    PLOS ONE, 2023, 18 (05):
  • [47] A prelude to outreach:: Prevalence & mortality of ward patients with abnormal vital signs
    Ashworth, S
    INTENSIVE CARE MEDICINE, 2002, 28 : S21 - S21
  • [48] A Feasibility Study for Life Signs Monitoring via a Continuous-Wave Radar
    Soldovieri, Francesco
    Catapano, Ilaria
    Crocco, Lorenzo
    Anishchenko, Lesya N.
    Ivashov, Sergey I.
    INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2012, 2012
  • [49] Outcomes in patients receiving continuous monitoring of vital signs on general wards: A systematic review and meta-analysis of randomised controlled trials
    Bowles, Tim
    Trentino, Kevin M.
    Lloyd, Adam
    Trentino, Laura
    Jones, Glynis
    Murray, Kevin
    Thompson, Aleesha
    Halpin, Sarah
    Waterer, Grant
    DIGITAL HEALTH, 2024, 10
  • [50] Frequency of Vital Signs Monitoring and its Association with Mortality among Adults with Severe Sepsis Admitted to a General Medical Ward in Uganda
    Asiimwe, Stephen B.
    Okello, Samson
    Moore, Christopher C.
    PLOS ONE, 2014, 9 (02):