Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study

被引:22
|
作者
Leenen, Jobbe P. L. [1 ,2 ]
Dijkman, Eline M. [1 ]
van Dijk, Joris D. [3 ]
van Westreenen, Henderik L. [1 ]
Kalkman, Cor [4 ]
Schoonhoven, Lisette [5 ,6 ]
Patijn, Gijsbert A. [1 ]
机构
[1] Dept Surg, Isala, Zwolle, Netherlands
[2] Connected Care Ctr, Isala, Zwolle, Netherlands
[3] Isala Acad, Isala, Zwolle, Netherlands
[4] UMC Utrecht, Anesthesiol, Utrecht, Netherlands
[5] UMC Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[6] Univ Southampton, Fac Hlth Sci, Southampton, Hants, England
来源
BMJ OPEN | 2021年 / 11卷 / 02期
关键词
surgery; health & safety; adverse events; pancreatic surgery; hepatobiliary surgery; colorectal surgery; EARLY WARNING SCORES; MORTALITY; COMPLICATIONS; IMPACT; CLASSIFICATION; SAFETY; SYSTEM;
D O I
10.1136/bmjopen-2020-042735
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. Design Observational cohort study. Setting Tertiary teaching hospital. Participants Postoperative abdominal surgical patients (n=30) and nurses (n=23). Interventions Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. Outcomes System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. Results Thirty patients were monitored for a median duration of 81 hours (IQR 47-143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1-4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2-4.8) and satisfaction 3.7 (IQR 3.2-4.8), but agreed on ease of learning at 5.0 (IQR 4.0-5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. Conclusions Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses' ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Potential of threshold-based scores to support wireless vital signs monitoring for complication detection in surgical ward patients
    van Rossum, Mathilde
    Kouwenhoven, Ewout
    Bekhuis, Robin
    Hegeman, Han
    Folbert, Ellis
    Vollenbroek-Hutten, Miriam
    Kalkman, Cor
    Hermens, Hermie
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1478 - 1479
  • [22] Continuous monitoring of vital signs and clinical deterioration in frail elderly cardiac surgery patients: AGE AWARE study: A prospective cohort study
    Arends, Britta C.
    van Oud-Alblas, Heleen J. Blusse
    van Dongen, Eric PA.
    Biesma, Douwe H.
    Vernooij, Lisette M.
    Noordzij, Peter G.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2024, 41 (07) : 535 - 537
  • [23] Patient attitudes towards remote continuous vital signs monitoring on general surgery wards: An interview study
    Downey, C. L.
    Brown, J. M.
    Jayne, D. G.
    Randell, R.
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2018, 114 : 52 - 56
  • [24] Cost utility analysis of continuous and intermittent versus intermittent vital signs monitoring in patients admitted to surgical wards
    Javanbakht, Mehdi
    Mashayekhi, Atefeh
    Trevor, Miranda
    Hemami, Mohsen Rezaei
    Downey, Candice L.
    Branagan-Harris, Michael
    Atkinson, Jowan
    JOURNAL OF MEDICAL ECONOMICS, 2020, 23 (07) : 728 - 736
  • [25] Feasibility of daily vital signs monitoring (VSM) in COPD
    France, Grace
    Greening, Neil J.
    Esliger, Dale
    Steiner, Michael C.
    Singh, Sally J.
    Orme, Mark W.
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [26] Feasibility Study of Wearable Mixed Reality platform to the Vital Signs Remote Monitoring
    Franzo, Michela
    Bini, Fabiano
    Finti, Alessia
    Di Lucchio, Loredana
    Marinozzi, Franco
    2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,
  • [27] Remote wireless vital signs monitoring on the ward for early detection of deteriorating patients: A case series
    Posthuma, L. M.
    Downey, C.
    Visscher, M. J.
    Ghazali, D. A.
    Joshi, M.
    Ashrafian, H.
    Khan, S.
    Darzi, A.
    Goldstone, J.
    Preckel, B.
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2020, 104
  • [28] Vital sign deviations in hospitalized patients with COVID-19: An observational study with continuous monitoring
    Gronbaek, K. K.
    Rasmussen, S. M.
    Langer, N. H.
    Vincentz, M.
    Oxboll, A. -B.
    Sogaard, M.
    Awada, H. N.
    Sorensen, H. B.
    Aasvang, E. K.
    Meyhoff, C. S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2023, 67 (04) : 560 - 560
  • [29] Research on Continuous Vital Signs Monitoring Based on WBAN
    Yu, Lina
    Guo, Liqun
    Deng, Huanfang
    Lin, Kequan
    Yu, Limin
    Gao, Wanlin
    Saeed, Iftikhar Ahmed
    INCLUSIVE SMART CITIES AND DIGITAL HEALTH, 2016, 9677 : 371 - 382
  • [30] Continuous versus intermittent vital signs monitoring in patients admitted to surgical wards: a cluster-randomised, controlled trial
    Downey, C.
    Randell, R.
    Brown, J.
    Jayne, D.
    BRITISH JOURNAL OF SURGERY, 2018, 105 : 200 - 200